메뉴 건너뛰기




Volumn 52, Issue 3, 2011, Pages 1716-1722

Total corneal power estimation: Ray tracing method versus Gaussian optics formula

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANALYTIC METHOD; ANALYTICAL ERROR; ARTICLE; CONTROLLED STUDY; CORNEA THICKNESS; CORNEAL POWER; EYE REFRACTION; GAUSSIAN OPTICS FORMULA; HUMAN; HUMAN TISSUE; HYPERMETROPIA; INTERMETHOD COMPARISON; KERATOMILEUSIS; MAJOR CLINICAL STUDY; MYOPIA; PHOTOREFRACTIVE KERATECTOMY; PRIORITY JOURNAL; RAY TRACING METHOD; REFRACTIVE SURGERY; THEORETICAL MODEL; VISUAL SYSTEM FUNCTION;

EID: 79955940554     PISSN: 01460404     EISSN: 15525783     Source Type: Journal    
DOI: 10.1167/iovs.09-4982     Document Type: Article
Times cited : (111)

References (13)
  • 1
    • 0033982255 scopus 로고    scopus 로고
    • Comparison of changes in manifest refraction and corneal power after photorefractive keratectomy
    • Hugger P, Kohnen T, La Rosa FA, Holladay JT, Koch DD. Comparison of changes in manifest refraction and corneal power after photorefractive keratectomy. Am J Ophthalmol. 2000;129:68-75.
    • (2000) Am J Ophthalmol , vol.129 , pp. 68-75
    • Hugger, P.1    Kohnen, T.2    la Rosa, F.A.3    Holladay, J.T.4    Koch, D.D.5
  • 2
    • 0036205558 scopus 로고    scopus 로고
    • A comparative analysis of five methods of determining corneal refractive power in eyes that have undergone myopic laser in situ keratomileusis
    • Hamed AM, Wang L, Misra M, Koch DD. A comparative analysis of five methods of determining corneal refractive power in eyes that have undergone myopic laser in situ keratomileusis. Ophthalmology. 2002;109:651-658.
    • (2002) Ophthalmology , vol.109 , pp. 651-658
    • Hamed, A.M.1    Wang, L.2    Misra, M.3    Koch, D.D.4
  • 3
    • 0033966206 scopus 로고    scopus 로고
    • Intraocular lens calculations status after corneal refractive surgery
    • Seitz B, Langenbucher A. Intraocular lens calculations status after corneal refractive surgery. Curr Opin Ophthalmol. 2000;11: 35-46.
    • (2000) Curr Opin Ophthalmol , vol.11 , pp. 35-46
    • Seitz, B.1    Langenbucher, A.2
  • 4
    • 0004038248 scopus 로고
    • 10th ed. London: Butterworths
    • Freeman MH. Optics. 10th ed. London: Butterworths; 1990:115-120.
    • (1990) Optics , pp. 115-120
    • Freeman, M.H.1
  • 5
    • 56249126473 scopus 로고    scopus 로고
    • Effective corneal refractive zone in terms of Gaussian optics
    • Harris WF. Effective corneal refractive zone in terms of Gaussian optics. J Cataract Refract Surg. 2008;34:2030-2035.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 2030-2035
    • Harris, W.F.1
  • 6
    • 0027943021 scopus 로고
    • The accuracy of power maps to display curvature data in corneal topography systems
    • Roberts C. The accuracy of power maps to display curvature data in corneal topography systems. Invest Ophthalmol Vis Sci. 1994; 35:3525-3532.
    • (1994) Invest Ophthalmol Vis Sci , vol.35 , pp. 3525-3532
    • Roberts, C.1
  • 7
    • 33751325375 scopus 로고    scopus 로고
    • Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula
    • Borasio E, Stevens J, Smith GT. Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula. J Cataract Refract Surg. 2006;32:2004-2014.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 2004-2014
    • Borasio, E.1    Stevens, J.2    Smith, G.T.3
  • 8
    • 67649360554 scopus 로고    scopus 로고
    • Agreement between Pentacam and videokeratography in corneal power assessment
    • Savini G, Barboni P, Carbonelli M, Hoffer KJ. Agreement between Pentacam and videokeratography in corneal power assessment. J Refract Surg. 2009;25:534-538.
    • (2009) J Refract Surg , vol.25 , pp. 534-538
    • Savini, G.1    Barboni, P.2    Carbonelli, M.3    Hoffer, K.J.4
  • 9
    • 33750440764 scopus 로고    scopus 로고
    • Measuring total corneal power before and after laser in situ keratomileusis with high-speed optical coherence tomography
    • Tang M, Li Y, Avila M, Huang D. Measuring total corneal power before and after laser in situ keratomileusis with high-speed optical coherence tomography. J Cataract Refract Surg. 2006;32:1843-1850.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 1843-1850
    • Tang, M.1    Li, Y.2    Avila, M.3    Huang, D.4
  • 10
    • 37349064395 scopus 로고    scopus 로고
    • Pentacam keratometry and IOL power calculation
    • Norrby S. Pentacam keratometry and IOL power calculation. J Cataract Refract Surg. 2008;34:3.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 3
    • Norrby, S.1
  • 11
    • 0022655651 scopus 로고
    • On the calculation of power from curvature of the cornea
    • Olsen T. On the calculation of power from curvature of the cornea. Br J Ophthalmol. 1986;70:152-154.
    • (1986) Br J Ophthalmol , vol.70 , pp. 152-154
    • Olsen, T.1
  • 12
    • 0036667901 scopus 로고    scopus 로고
    • Radius and asphericity of the posterior corneal surface determined by corrected Scheimpflug photography
    • Dubbelman M, Van der Heijde GL, Weeber HA, Vrensen GF. Radius and asphericity of the posterior corneal surface determined by corrected Scheimpflug photography. Acta Ophthalmol Scand. 2002;80:379-383.
    • (2002) Acta Ophthalmol Scand , vol.80 , pp. 379-383
    • Dubbelman, M.1    van der Heijde, G.L.2    Weeber, H.A.3    Vrensen, G.F.4
  • 13
    • 0032470733 scopus 로고    scopus 로고
    • Unfortunate discrepancies
    • Norrby NE. Unfortunate discrepancies. J Cataract Refract Surg. 1998;24:433-434.
    • (1998) J Cataract Refract Surg , vol.24 , pp. 433-434
    • Norrby, N.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.