Volumn 34, Issue 4, 2011, Pages 928-945

Performance analysis of desiccant dehumidification systems driven by low-grade heat source

Author keywords

Air conditioning; Dehumidification; Desiccant; Desiccant wheel; Optimization; Silica gel

Indexed keywords

AIR CONDITIONERS; BATCH TYPE; CONVENTIONAL SYSTEMS; DEHUMIDIFICATION; DESICCANT; DESICCANT DEHUMIDIFICATION SYSTEMS; DESICCANT WHEEL; DESICCANT WHEELS; EXHAUST HEAT; HEAT SOURCES; HEATED AIR; INTERNAL HEAT EXCHANGER; LOW-GRADE HEATS; PERFORMANCE ANALYSIS; PRE-COOLER; SAVING ENERGY; SIMULATION MODEL; WHEEL-TYPE;

EID: 79955914981     PISSN: 01407007     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrefrig.2010.10.001     Document Type: Article
Times cited : (70)

References (15)
  • 1
    • 0003842308 scopus 로고    scopus 로고
    • American Society of Heating, Refrigerating and Air Conditioning Engineers, Inc. Atlanta GA, USA
    • ASHRAE ASHRAE Handbook - Fundamentals 2001 American Society of Heating, Refrigerating and Air Conditioning Engineers, Inc. Atlanta GA, USA
    • (2001) ASHRAE Handbook - Fundamentals
  • 3
    • 0012827614 scopus 로고    scopus 로고
    • Studies on solid desiccant based hybrid air-conditioning systems
    • DOI 10.1016/S1359-4311(00)00035-1, PII S1359431100000351
    • P.L. Dhar, and S.K. Singh Studies on solid desiccant based hybrid air conditioning systems Appl. Therm. Eng. 21 2 2001 119 134 (Pubitemid 33648344)
    • (2001) Applied Thermal Engineering , vol.21 , Issue.2 , pp. 119-134
    • Dhar, P.L.1    Singh, S.K.2
  • 4
    • 0036668293 scopus 로고    scopus 로고
    • The use of solar desiccant cooling in the UK: A feasibility study
    • DOI 10.1016/S1359-4311(02)00052-2, PII S1359431102000522
    • S.P. Halliday, C.B. Beggs, and P.A. Sleigh The use of solar desiccant cooling in the UK: a feasibility study Appl. Therm. Eng. 22 2002 1327 1338 (Pubitemid 34704489)
    • (2002) Applied Thermal Engineering , vol.22 , Issue.12 , pp. 1327-1338
    • Halliday, S.P.1    Beggs, C.B.2    Sleigh, P.A.3
  • 6
    • 0002162763 scopus 로고
    • Darstellung des warmeuberganges in rohren durch verallgemeinerte potenzbeziehungen
    • H. Hausen Darstellung des warmeuberganges in rohren durch verallgemeinerte potenzbeziehungen Z. VDI Beihefte Verfahrenstechnik 4 1943 91
    • (1943) Z. VDI Beihefte Verfahrenstechnik , vol.4 , pp. 91
    • Hausen, H.1
  • 8
    • 33745262084 scopus 로고    scopus 로고
    • Analysis on a hybrid desiccant air-conditioning system
    • DOI 10.1016/j.applthermaleng.2006.02.016, PII S1359431106000597
    • C.X. Jia, Y.J. Dai, J.Y. Wu, and R.Z. Wang Analysis on a hybrid desiccant air conditioning system Appl. Therm. Eng. 26 2006 2393 2400 (Pubitemid 43928749)
    • (2006) Applied Thermal Engineering , vol.26 , Issue.17-18 , pp. 2393-2400
    • Jia, C.X.1    Dai, Y.J.2    Wu, J.Y.3    Wang, R.Z.4
  • 9
    • 0036629134 scopus 로고    scopus 로고
    • The potential for solar powered single-stage desiccant cooling in southern Europe
    • DOI 10.1016/S1359-4311(02)00034-0, PII S1359431102000340
    • P. Mavroudaki, C.B. Beggs, P.A. Sleigh, and S.P. Haliiday The potential for solar powered single-stage desiccant cooling in southern Euro Appl. Therm. Eng. 22 2002 1129 1140 (Pubitemid 34551924)
    • (2002) Applied Thermal Engineering , vol.22 , Issue.10 , pp. 1129-1140
    • Mavroudaki, P.1    Beggs, C.B.2    Sleigh, P.A.3    Halliday, S.P.4
  • 10
    • 0008438384 scopus 로고
    • Desiccant-assisted air conditioner improves IAQ and comfort
    • M. Meckler Desiccant-assisted air conditioner improves IAQ and comfort Heating/Piping/Air Conditioning 1994 75 84
    • (1994) Heating/Piping/Air Conditioning , pp. 75-84
    • Meckler, M.1
  • 11
    • 0000901517 scopus 로고
    • Laminar flow friction and forced convection heat transfer in ducts of arbitrary geometry
    • R.K. Shah Laminar flow friction and forced convection heat transfer in ducts of arbitrary geometry Int. J. Heat Mass Transfer 18 1975 849 862
    • (1975) Int. J. Heat Mass Transfer , vol.18 , pp. 849-862
    • Shah, R.K.1
  • 12
    • 76849099083 scopus 로고    scopus 로고
    • Study on multistage desiccant air conditioning system driven by lower heat source temperature
    • (in Japanese)
    • Shibao, Y.; Yamaguchi, S.; Saito, K.; Kawai, S.; 2006. Study on multistage desiccant air conditioning system driven by lower heat source temperature. In: Proc. 2006 JSRAE Annual Conf.; pp. 257-260 (in Japanese).
    • (2006) Proc. 2006 JSRAE Annual Conf. , pp. 257-260
    • Shibao, Y.1    Yamaguchi, S.2    Saito, K.3    Kawai, S.4
  • 13
    • 79955928091 scopus 로고    scopus 로고
    • Performance analysis of multi-partition desiccant wheel
    • ICR07-E1-1011
    • Shibao, Y.; Yamaguchi, S.; Saito, K.; Kawai, S.; 2007. Performance analysis of multi-partition desiccant wheel. In: Proc. 22nd ICR, ICR07-E1-1011.
    • (2007) Proc. 22nd ICR
    • Shibao, Y.1    Yamaguchi, S.2    Saito, K.3    Kawai, S.4
  • 14
    • 0029386743 scopus 로고
    • Vapour-compression and liquid-desiccant hybrid solar space-conditioning system for energy conservation
    • Y.K. Yadav Vapour-compression and liquid-desiccant hybrid solar space-conditioning system for energy conservation Renew. Energy 7 1995 719 723
    • (1995) Renew. Energy , vol.7 , pp. 719-723
    • Yadav, Y.K.1