Volumn 13, Issue 2, 2011, Pages 153-166

Leak detection by inverse transient analysis in an experimental PVC pipe system

Author keywords

Calibration; Hydraulic transients; Inverse models; Leak detection; Plastic pipes

Indexed keywords


EID: 79955882053     PISSN: 14647141     EISSN: None     Source Type: Journal    
DOI: 10.2166/hydro.2010.012     Document Type: Article
Times cited : (81)

References (28)
  • 3
    • 0035182798 scopus 로고    scopus 로고
    • Detecting leaks in pressurised pipes by means of transients
    • Brunone, B.& Ferrante,M. 2001 Detecting leaks in pressurised pipes by means of transients. J. Hydraul. Res. 39(5), 539-548.
    • (2001) J. Hydraul. Res. , vol.39 , Issue.5 , pp. 539-548
    • Brunone, B.1    Ferrante, M.2
  • 4
    • 28744445123 scopus 로고
    • Applied hydraulic transients 2nd edn
    • New York
    • Chaudhry, M. H. 1987 Applied Hydraulic Transients 2nd edn. Van Nostrand Reinhold, New York.
    • (1987) Van Nostrand Reinhold
    • Chaudhry, M.H.1
  • 5
    • 4444382747 scopus 로고    scopus 로고
    • Inverse transient analysis for leak detection and calibration of water pipe systems - Modelling special dynamic effects
    • PhD thesis, Technology and Medicine, University of London
    • Covas, D. 2003 Inverse Transient Analysis for Leak Detection and Calibration of Water Pipe Systems - Modelling Special Dynamic Effects. PhD thesis, Imperial College of Science, Technology and Medicine, University of London.
    • (2003) Imperial College of Science
    • Covas, D.1
  • 6
    • 33645665691 scopus 로고    scopus 로고
    • Standing wave difference method for leakage detection in pipeline systems
    • Covas, D., Ramos, H. & Almeida, A. B. 2005a Standing wave difference method for leakage detection in pipeline systems. J. Hydraul. Engng. 131(12), 1106-1116.
    • (2005) J. Hydraul. Engng , vol.131 , Issue.12 , pp. 1106-1116
    • Covas, D.1    Ramos, H.2    Almeida, A.B.3
  • 8
    • 14744299171 scopus 로고    scopus 로고
    • The dynamic effect of pipe-wall viscoelasticity in hydraulic transients. Part II - Model development, calibration and verification
    • Covas, D., Stoianov, I., Mano, J., Ramos, H., Graham, N. & Maksimovic, C. 2005b The dynamic effect of pipe-wall viscoelasticity in hydraulic transients. Part II -Model development, calibration and verification. J. Hydraul. Res. 43(1), 56-70. (Pubitemid 40335320)
    • (2005) Journal of Hydraulic Research , vol.43 , Issue.1 , pp. 56-70
    • Covas, D.1    Stoianov, I.2    Mano, J.F.3    Ramos, H.4    Graham, N.5    Maksimovic, C.6
  • 9
    • 36448970548 scopus 로고    scopus 로고
    • Wavelets for the analysis of transient pressure signals for leak detection
    • DOI 10.1061/(ASCE)0733-9429(2007)133:11(1274)
    • Ferrante,M., Brunone, B.& Meniconi, S. 2007 Wavelets for the analysis of transient pressure signals for leak detection. J. Hydraul. Engng. 133(11), 1274-1282. (Pubitemid 350162142)
    • (2007) Journal of Hydraulic Engineering , vol.133 , Issue.11 , pp. 1274-1282
    • Ferrante, M.1    Brunone, B.2    Meniconi, S.3
  • 11
    • 0142120461 scopus 로고    scopus 로고
    • Un modèle instationnaire inverse hybride pour la détection de fuite et l'étalonnage de la rugosité dans des réseaux de tuyaux
    • supplement
    • Kapelan, Z., Savic, D. & Walters, G. 2003 A hybrid inverse transient model for leakage detection and roughness calibration in pipe networks. J. Hydraul. Res. 41(5), 481-492. (Pubitemid 37293365)
    • (2003) Journal of Hydraulic Research , vol.41 , Issue.5 , pp. 481-492
    • Kapelan, Z.S.1    Savic, D.A.2    Walters, G.A.3
  • 15
    • 0035241789 scopus 로고    scopus 로고
    • Leak detection in pipes by frequency response method
    • DOI 10.1061/(ASCE)0733-9429(2001)127:2(134)
    • Mpesha,W., Gassman, S. L. & Chaudhry, M. H. 2001 Leak detection in pipes by frequency response method. J. Hydraul. Engng. 127(2), 134-147. (Pubitemid 32158865)
    • (2001) Journal of Hydraulic Engineering , vol.127 , Issue.2 , pp. 134-147
    • Mpesha, W.1    Gassman, S.L.2    Chaudhry, M.H.3
  • 16
    • 68149149091 scopus 로고    scopus 로고
    • Quo vadis water distribution model calibration
    • Savic, D. A., Kapelan, Z. S. & Jonkergouw, P. M. R. 2009 Quo vadis water distribution model calibration? Urban Wat. J. 6(1), 3-22.
    • (2009) Urban Wat. J. , vol.6 , Issue.1 , pp. 3-22
    • Savic, D.A.1    Kapelan, Z.S.2    Jonkergouw, P.M.R.3
  • 18
    • 50049135370 scopus 로고    scopus 로고
    • Analysis of PVC pipe-wall viscoelasticity during water hammer
    • Soares, A. K., Covas, D. I. C. & Reis, L. F. R. 2008a Analysis of PVC pipe-wall viscoelasticity during water hammer. J. Hydraul. Engng. 134(9), 1389-1394.
    • (2008) J. Hydraul. Engng , vol.134 , Issue.9 , pp. 1389-1394
    • Soares, A.K.1    Covas, D.I.C.2    Reis, L.F.R.3
  • 20
    • 27544488676 scopus 로고    scopus 로고
    • Head-driven simulation model (HDSM) for water distribution system calibration
    • Maksimovic, C.Butler, D.Memon, F. Eds., A.A. Balkema, Lisse, The Netherlands
    • Soares, A. K., Reis, L. F. R.& Carrijo, I. B. 2003 Head-driven simulation model (HDSM) for water distribution system calibration. In: Proc. Int. Conf. on Advances in Water Supply Management (CCWI 2003) (Maksimovic, C.Butler, D.Memon, F. (Eds.)). A.A. Balkema, Lisse, The Netherlands, pp 197-207.
    • (2003) Proc. Int. Conf. on Advances in Water Supply Management (CCWI 2003) , pp. 197-207
    • Soares, A.K.1    Reis, L.F.R.2    Carrijo, I.B.3
  • 24
    • 0033102634 scopus 로고    scopus 로고
    • Leak analysis in pipeline systems by means of optimal valve regulation
    • DOI 10.1061/(ASCE)0733-9429(1999)125:3(277)
    • Tucciarelli, T., Criminisi, A. & Termini, D. 1999 Leak analysis in pipeline systems by means of optimal valve regulation. J. Hydraul. Engng. 125(3), 277-285. (Pubitemid 29384350)
    • (1999) Journal of Hydraulic Engineering , vol.125 , Issue.3 , pp. 277-285
    • Tucciarelli, T.1    Criminisi, A.2    Termini, D.3
  • 25
    • 35348958826 scopus 로고    scopus 로고
    • A global and efficient multi-objective auto-calibration and uncertainty estimation method for water quality catchment models
    • Van Griensven, A. & Meixner, T. 2007 A global and efficient multi-objective auto-calibration and uncertainty estimation method for water quality catchment models. J. Hydroinf. 9(4), 277-291.
    • (2007) J. Hydroinf , vol.9 , Issue.4 , pp. 277-291
    • Van Griensven, A.1    Meixner, T.2
  • 27
    • 0342626863 scopus 로고    scopus 로고
    • Leak detection and calibration using transients and genetic algorithms
    • DOI 10.1061/(ASCE)0733-9496(2000)126:4(262)
    • Vítkovský , J. P., Simpson, A. R. & Lambert, M. F. 2000 Leak detection and calibration issues using transient and genetic algorithms. J. Wat. Res. Plann. Mngmnt. 126(4), 262-265. (Pubitemid 30454426)
    • (2000) Journal of Water Resources Planning and Management , vol.126 , Issue.4 , pp. 262-265
    • Vitkovsky, J.P.1    Simpson, A.R.2    Lambert, M.F.3