메뉴 건너뛰기




Volumn 32, Issue 4, 2010, Pages 287-297

Inertial Gait Phase Detection for control of a drop foot stimulator. Inertial sensing for gait phase detection.

Author keywords

Accelerometers; Algorithms; Drop foot; FES; Gait phase; Gyroscopes; Inertial

Indexed keywords

COMPUTATIONAL LOADS; FES; FLAT SURFACES; FORCE PLATE; GAIT PHASE DETECTION; GAIT-PHASE; INERTIAL; INERTIAL SENSING; INERTIAL SENSOR; POWER REQUIREMENT; REFERENCE SYSTEMS; ROUGH TERRAINS; SENSOR COMPONENTS; SENSOR SYSTEMS; TIMING ANALYSIS; WEIGHT SHIFT;

EID: 79955847399     PISSN: 13504533     EISSN: 18734030     Source Type: Journal    
DOI: 10.1016/j.medengphy.2009.10.014     Document Type: Article
Times cited : (132)

References (21)
  • 1
    • 73049136842 scopus 로고
    • Functional electrotherapy: stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients
    • Liberson W.T., Holmquest H.J., Scott D., Dow A. Functional electrotherapy: stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients. Arch Phys Med Rehab 1961, 42:101-105.
    • (1961) Arch Phys Med Rehab , vol.42 , pp. 101-105
    • Liberson, W.T.1    Holmquest, H.J.2    Scott, D.3    Dow, A.4
  • 2
    • 0036991511 scopus 로고    scopus 로고
    • A review of portable FES-based neural orthoses for the correction of drop foot
    • Lyons G.M., Sinkjaer T. A review of portable FES-based neural orthoses for the correction of drop foot. IEEE Trans Neural Syst Rehabil Eng 2002, 10(4):260-279.
    • (2002) IEEE Trans Neural Syst Rehabil Eng , vol.10 , Issue.4 , pp. 260-279
    • Lyons, G.M.1    Sinkjaer, T.2
  • 6
    • 0024764104 scopus 로고
    • Automatic detection of gait events: a case study using inductive learning techniques
    • Kirkwood C.A., Andrews B.J., Mowforth P. Automatic detection of gait events: a case study using inductive learning techniques. J Biomed Eng 1989, 11:511-516.
    • (1989) J Biomed Eng , vol.11 , pp. 511-516
    • Kirkwood, C.A.1    Andrews, B.J.2    Mowforth, P.3
  • 8
    • 0024053914 scopus 로고
    • Above- and below-lesion EMG pattern mapping for controlling electrical stimulation of paraplegics to facilitate unbraced walker-assisted walking
    • Graupe D., Kohn K.H., Basseas S. Above- and below-lesion EMG pattern mapping for controlling electrical stimulation of paraplegics to facilitate unbraced walker-assisted walking. J Biomed Eng 1988, 10(4):305-311.
    • (1988) J Biomed Eng , vol.10 , Issue.4 , pp. 305-311
    • Graupe, D.1    Kohn, K.H.2    Basseas, S.3
  • 9
    • 0028385607 scopus 로고
    • Artifact-free sensory nerve signals obtained from cuff electrodes during functional electrical stimulation of nearby muscles
    • Haugland M.K., Hoffer J.A. Artifact-free sensory nerve signals obtained from cuff electrodes during functional electrical stimulation of nearby muscles. IEEE Trans Rehabil Eng 1994, 2(1):37-40.
    • (1994) IEEE Trans Rehabil Eng , vol.2 , Issue.1 , pp. 37-40
    • Haugland, M.K.1    Hoffer, J.A.2
  • 10
    • 0030953507 scopus 로고    scopus 로고
    • Natural versus artificial sensors applied in peroneal nerve stimulation
    • Upshaw B.J., Sinkjaer T. Natural versus artificial sensors applied in peroneal nerve stimulation. Artif Organs 1997, 21(3):227-231.
    • (1997) Artif Organs , vol.21 , Issue.3 , pp. 227-231
    • Upshaw, B.J.1    Sinkjaer, T.2
  • 11
    • 0025661988 scopus 로고
    • Automatic stance-swing phase detection from accelerometer data for peroneal nerve stimulation
    • Willemsen A.T., Bloemhof F., Bloom H.B. Automatic stance-swing phase detection from accelerometer data for peroneal nerve stimulation. IEEE Trans Biomed Eng 1990, 37(12):1201-1208.
    • (1990) IEEE Trans Biomed Eng , vol.37 , Issue.12 , pp. 1201-1208
    • Willemsen, A.T.1    Bloemhof, F.2    Bloom, H.B.3
  • 12
    • 0030176016 scopus 로고    scopus 로고
    • Application of tilt sensors in functional electrical stimulation
    • Dai R., Stein R.B. Application of tilt sensors in functional electrical stimulation. IEEE Trans Rehabil Eng 1996, 4(2):63-72.
    • (1996) IEEE Trans Rehabil Eng , vol.4 , Issue.2 , pp. 63-72
    • Dai, R.1    Stein, R.B.2
  • 13
    • 0034244011 scopus 로고    scopus 로고
    • Motion pattern and posture: correctly assessed by calibrated accelerometers
    • Foerster F., Fahreberg J. Motion pattern and posture: correctly assessed by calibrated accelerometers. Behav Res Methods Instrum Comput 2000, 32(3):450-457.
    • (2000) Behav Res Methods Instrum Comput , vol.32 , Issue.3 , pp. 450-457
    • Foerster, F.1    Fahreberg, J.2
  • 14
    • 0036221730 scopus 로고    scopus 로고
    • Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
    • Aminian K., Najafi B., Bula C., Leyvraz P.F., Robert P.H. Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes. J Biomech 2002, 35(5):689-699.
    • (2002) J Biomech , vol.35 , Issue.5 , pp. 689-699
    • Aminian, K.1    Najafi, B.2    Bula, C.3    Leyvraz, P.F.4    Robert, P.H.5
  • 17
    • 34047175982 scopus 로고    scopus 로고
    • A compact wearable sensor package for clinical gait monitoring
    • Morris S.J., Paradiso J.A. A compact wearable sensor package for clinical gait monitoring. Offspring - Motorola 2003, 1(1):7-15.
    • (2003) Offspring - Motorola , vol.1 , Issue.1 , pp. 7-15
    • Morris, S.J.1    Paradiso, J.A.2
  • 20
    • 0016033822 scopus 로고
    • Measurement and reduction of noise in kinematics of locomotion
    • Winter D.A., Sidwall H.G., Hobson D.A. Measurement and reduction of noise in kinematics of locomotion. J Biomech 1974, 7(2):157-159.
    • (1974) J Biomech , vol.7 , Issue.2 , pp. 157-159
    • Winter, D.A.1    Sidwall, H.G.2    Hobson, D.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.