메뉴 건너뛰기




Volumn 14, Issue 1, 2011, Pages 67-69

Use of DuraHeart® support for more than 1 year as the first successful bridge to heart transplantation in Japan

Author keywords

Bridge to transplantation; DuraHeart ; Ventricular assist devices

Indexed keywords

CATECHOLAMINE;

EID: 79955841038     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-010-0524-x     Document Type: Article
Times cited : (23)

References (9)
  • 3
    • 33750566081 scopus 로고    scopus 로고
    • The DuraHeart VAD, a magnetically levitated centrifugal pump - The University of Vienna bridge-to-transplant experience
    • DOI 10.1253/circj.70.1421
    • Nishinaka T, Schima H, Roethy W, Rajek A, Nojiri C, Wolner E, Wieselthaler GM. The DuraHeart VAD, a magnetically levitated centrifugal pump: the University of Vienna bridge-to-transplant experience. Circ J. 2006;70:1421-5. (Pubitemid 44672897)
    • (2006) Circulation Journal , vol.70 , Issue.11 , pp. 1421-1425
    • Nishinaka, T.1    Schima, H.2    Roethy, W.3    Rajek, A.4    Nojiri, C.5    Wolner, E.6    Wieselthaler, G.M.7
  • 5
    • 34447295967 scopus 로고    scopus 로고
    • Implantation technique for the DuraHeart left ventricular assist system
    • DOI 10.1007/s10047-007-0374-3
    • Komoda T, Weng Y, Nojiri C, Hetzer R. Implantation technique for the DuraHeart left ventricular assist system. J Artif Organs. 2007;10:124-7. (Pubitemid 47051347)
    • (2007) Journal of Artificial Organs , vol.10 , Issue.2 , pp. 124-127
    • Komoda, T.1    Weng, Y.2    Nojiri, C.3    Hetzer, R.4
  • 6
    • 33244462218 scopus 로고    scopus 로고
    • Abdominal complications of ventricular assist device placement
    • DOI 10.1089/sur.2005.6.409
    • Costantini TW, Taylor JH, Beilman GJ. Abdominal complications of ventricular assist device placement. Surg Infect (Larchmt). 2005;6:409-18. (Pubitemid 43272411)
    • (2005) Surgical Infections , vol.6 , Issue.4 , pp. 409-418
    • Costantini, T.W.1    Taylor, J.H.2    Beilman, G.J.3
  • 7
    • 2542492930 scopus 로고    scopus 로고
    • Diaphragmatic hernias associated with ventricular assist devices and heart transplantation
    • DOI 10.1016/j.athoracsur.2003.10.108, PII S0003497503023269
    • Chatterjee S, Williams NN, Ohara ML, Twomey C, Morris JB, Acker MA. Diaphragmatic hernias associated with ventricular assist devices and heart transplantation. Ann Thorac Surg. 2004;77:2111-4. (Pubitemid 38686597)
    • (2004) Annals of Thoracic Surgery , vol.77 , Issue.6 , pp. 2111-2114
    • Chatterjee, S.1    Williams, N.N.2    Ohara, M.L.3    Twomey, C.4    Morris, J.B.5    Acker, M.A.6
  • 9
    • 78149408285 scopus 로고    scopus 로고
    • Study of device malfunctions in patients with implantable ventricular assist devices living at home
    • Kashiwa K, Nishimura T, Kubo H, Tamai H, Baba A, Ono M, Takamoto S, Kyo S. Study of device malfunctions in patients with implantable ventricular assist devices living at home. J Artif Organs. 2010;13:134-8.
    • (2010) J Artif Organs , vol.13 , pp. 134-138
    • Kashiwa, K.1    Nishimura, T.2    Kubo, H.3    Tamai, H.4    Baba, A.5    Ono, M.6    Takamoto, S.7    Kyo, S.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.