메뉴 건너뛰기




Volumn 7965, Issue , 2011, Pages

Experimental demonstration of x-space magnetic particle imaging

Author keywords

Bandwidth; Magnetic particle imaging; Resolution; X space

Indexed keywords

DATA SUPPORT; EXPERIMENTAL TEST; HUMAN-SIZE; IMAGE RECONSTRUCTION TECHNIQUES; IMAGE SIZES; IMAGE SPACE; LARGE IMAGES; MAGNETIC PARTICLE IMAGING; MATRIX INVERSE; NOISE GAIN; RAW SIGNALS; RESOLUTION; SHIFT INVARIANT SYSTEMS; SMALL SCALE; SPATIAL RESOLUTION; SYSTEM FUNCTIONS; TIME-SCALES; X-SPACE;

EID: 79955824335     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.878659     Document Type: Conference Paper
Times cited : (9)

References (11)
  • 1
    • 78149248339 scopus 로고    scopus 로고
    • The x-space formulation of the magnetic particle imaging process: One-dimensional signal, resolution, bandwidth, SNR, SAR, and magnetostimulation
    • Jun
    • P. W. Goodwill and S. M. Conolly, "The x-Space Formulation of the Magnetic Particle Imaging process: One-Dimensional Signal, Resolution, Bandwidth, SNR, SAR, and Magnetostimulation, " IEEE Trans. Med. Imaging, Jun 2010.
    • (2010) IEEE Trans. Med. Imaging
    • Goodwill, P.W.1    Conolly, S.M.2
  • 2
    • 21744445797 scopus 로고    scopus 로고
    • Tomographic imaging using the nonlinear response of magnetic particles
    • DOI 10.1038/nature03808
    • B. Gleich and J. Weizenecker, "Tomographic imaging using the nonlinear response of magnetic particles, " Nature 435, pp. 1214-7, Jun 2005. (Pubitemid 40943083)
    • (2005) Nature , vol.435 , Issue.7046 , pp. 1214-1217
    • Gleich, B.1    Weizenecker, J.2
  • 3
    • 41049083386 scopus 로고    scopus 로고
    • Experimental results on fast 2D-encoded magnetic particle imaging
    • DOI 10.1088/0031-9155/53/6/N01, PII S0031915508646989
    • B. Gleich, J. Weizenecker, and J. Borgert, "Experimental results on fast 2d-encoded magnetic particle imaging, " Phys. Med. Biol. 53, pp. N81-N84, Feb 2008. (Pubitemid 351423011)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.6
    • Gleich, B.1    Weizenecker, J.2    Borgert, J.3
  • 7
    • 66149168708 scopus 로고    scopus 로고
    • Signal encoding in magnetic particle imaging: Properties of the system function
    • J. Rahmer, J. Weizenecker, B. Gleich, and J. Borgert, "Signal encoding in magnetic particle imaging: properties of the system function, " BMC Med. Imaging 9(1), p. 4, 2009.
    • (2009) BMC Med. Imaging , vol.9 , Issue.1 , pp. 4
    • Rahmer, J.1    Weizenecker, J.2    Gleich, B.3    Borgert, J.4
  • 8
    • 36048972710 scopus 로고    scopus 로고
    • A simulation study on the resolution and sensitivity of magnetic particle imaging
    • DOI 10.1088/0031-9155/52/21/001, PII S003191550755236X
    • J. Weizenecker, J. Borgert, and B. Gleich, "A simulation study on the resolution and sensitivity of magnetic particle imaging, " Phys. Med. Biol. 52, pp. 6363-74, Nov 2007. (Pubitemid 350093167)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.21 , pp. 6363-6374
    • Weizenecker, J.1    Borgert, J.2    Gleich, B.3
  • 10
    • 2442541185 scopus 로고    scopus 로고
    • Imaging below the diffraction limit: A statistical analysis
    • M. Shahram and P. Milanfar, "Imaging below the diffraction limit: A statistical analysis, " IEEE Trans. Image Process. 13(5), pp. 677-689, 2004.
    • (2004) IEEE Trans. Image Process. , vol.13 , Issue.5 , pp. 677-689
    • Shahram, M.1    Milanfar, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.