메뉴 건너뛰기




Volumn 14, Issue 1, 2011, Pages 74-79

A novel counterpulse drive mode of continuous-flow left ventricular assist devices can minimize intracircuit backward flow during pump weaning

Author keywords

Bridge to recovery; Left ventricular assist device; Mock circulation

Indexed keywords

AORTA PRESSURE; ARTICLE; CENTRIFUGATION; CONTROLLED STUDY; COUNTERPULSATION; DEVICE SAFETY; HEART CYCLE; HEART LEFT VENTRICLE PRESSURE; HEART PERFUSION; HEART RATE VARIABILITY; HEART VENTRICLE ENDDIASTOLIC PRESSURE; HEMODYNAMIC MONITORING; LEFT VENTRICULAR ASSIST DEVICE; PRIORITY JOURNAL; PROCESS DEVELOPMENT; PULSATILE FLOW; SYSTEMIC CIRCULATION;

EID: 79955814193     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-010-0544-6     Document Type: Article
Times cited : (14)

References (9)
  • 3
    • 54449083490 scopus 로고    scopus 로고
    • Prediction of cardiac stability after weaning from left ventricular assist device in patients with idiopathic dilated cardiomyopathy
    • Dandel M, Weng Y, Siniawski H, Potapov E, Drews T, Lehmkuhl HB, Knosalla C, Hetzer R. Prediction of cardiac stability after weaning from left ventricular assist device in patients with idiopathic dilated cardiomyopathy. Circulation. 2008;118:S94-105.
    • (2008) Circulation , vol.118
    • Dandel, M.1    Weng, Y.2    Siniawski, H.3    Potapov, E.4    Drews, T.5    Lehmkuhl, H.B.6    Knosalla, C.7    Hetzer, R.8
  • 4
    • 33645084581 scopus 로고    scopus 로고
    • Hemodynamics and patient safety during pump-off studies of an axial-flow left ventricular assist device
    • Myers TJ, Frazier OH, Mesina HS, Radovancevic B, Gregoric ID. Hemodynamics and patient safety during pump-off studies of an axial-flow left ventricular assist device. J Heart Lung Transplant. 2006;25:379-83.
    • (2006) J Heart Lung Transplant , vol.25 , pp. 379-383
    • Myers, T.J.1    Frazier, O.H.2    Mesina, H.S.3    Radovancevic, B.4    Gregoric, I.D.5
  • 6
    • 0031977417 scopus 로고    scopus 로고
    • The safety system for the rotary blood pump, combination of the valve and LVAD pulsatile mode: In vitro test
    • DOI 10.1046/j.1525-1594.1998.05068.x
    • Tayama E, Ohashi Y, Niimi Y, Takami Y, Ohtsuka G, Nakata K, Benkowski R, Glueck JA, Nosé Y. The safety system for the rotary blood pump, combination of the valve and LVAD pulsatile mode: in vitro test. Artif Organs. 1998;22:342-5. (Pubitemid 28188451)
    • (1998) Artificial Organs , vol.22 , Issue.4 , pp. 342-345
    • Tayama, E.1    Ohashi, Y.2    Niimi, Y.3    Takami, Y.4    Ohtsuka, G.5    Nakata, K.-I.6    Benkowski, R.7    Glueck, J.A.8    Nose, Y.9
  • 8
    • 0016156362 scopus 로고
    • Intraaortic balloon counterpulsation. A review of physiological principles, clinical results, and device safety
    • Weber KT, Janicki JS. Intraaortic balloon counterpulsation. A review of physiological principles, clinical results, and device safety. Ann Thorac Surg. 1974;17:602-36.
    • (1974) Ann Thorac Surg , vol.17 , pp. 602-636
    • Weber, K.T.1    Janicki, J.S.2
  • 9
    • 35548930345 scopus 로고    scopus 로고
    • Completely pulsatile high flow circulatory support with a constant-speed centrifugal blood pump: Mechanisms and early clinical observations
    • Yamazaki K, Saito S, Kihara S, Tagusari O, Kurosawa H. Completely pulsatile high flow circulatory support with a constant-speed centrifugal blood pump: mechanisms and early clinical observations. Gen Thorac Cardiovasc Surg. 2007;55:158-62.
    • (2007) Gen Thorac Cardiovasc Surg , vol.55 , pp. 158-162
    • Yamazaki, K.1    Saito, S.2    Kihara, S.3    Tagusari, O.4    Kurosawa, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.