메뉴 건너뛰기




Volumn 7961, Issue , 2011, Pages

Fast 4D cone-beam reconstruction using the McKinnon-Bates algorithm with truncation correction and nonlinear filtering

Author keywords

4D cone beam computed tomography (CBCT); bilateral filter; GPU; McKinnon Bates (MKB) algorithm

Indexed keywords

4D IMAGES; ALIASING ARTIFACTS; BILATERAL FILTER; CONE BEAM RECONSTRUCTION; CONE-BEAM COMPUTED TOMOGRAPHY; DATA TRUNCATION; GPU; GRAPHICAL PROCESSING UNITS; HIGH QUALITY; LOW SNR; LUNG TUMOR; MCKINNON-BATES (MKB) ALGORITHM; RADIATION THERAPY TREATMENT; SPATIAL RESOLUTION; TEMPORAL RESOLUTION;

EID: 79955771989     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.878226     Document Type: Conference Paper
Times cited : (13)

References (13)
  • 2
    • 34548314251 scopus 로고    scopus 로고
    • Enhanced 4D cone-beam CT with inter-phase motion model
    • DOI 10.1118/1.2767144
    • Li, T., Koong , A., Xing, L., "Enhanced 4D cone-beam CT with inter-phase motion model," Medical Physics 34(9), 3688-3695 (2007). (Pubitemid 47339766)
    • (2007) Medical Physics , vol.34 , Issue.9 , pp. 3688-3695
    • Li, T.1    Koong, A.2    Xing, L.3
  • 3
    • 38849164794 scopus 로고    scopus 로고
    • Prior image constrained compressed sensing
    • Chen, G. H., Tang, J., Leng, S., "Prior image constrained compressed sensing," Medical Physics 35(2), 660-663 (2008).
    • (2008) Medical Physics , vol.35 , Issue.2 , pp. 660-663
    • Chen, G.H.1    Tang, J.2    Leng, S.3
  • 4
    • 0019528381 scopus 로고
    • Towards imaging the beating heart usefully with a conventional CT scanner
    • McKinnon, G. C., Bates, R. H. T., "Towards imaging the beating heart usefully with a conventional CT scanner," IEEE Transaction on Biomedical Engineering 28(2), 123-127 (1981).
    • (1981) IEEE Transaction on Biomedical Engineering , vol.28 , Issue.2 , pp. 123-127
    • McKinnon, G.C.1    Bates, R.H.T.2
  • 5
    • 53149130183 scopus 로고    scopus 로고
    • Streaking artifacts reduction in four-dimensional cone-beam computed tomography
    • Leng, S. and Zambelli, J., "Streaking artifacts reduction in four-dimensional cone-beam computed tomography," Medical Physics 35(10), 4649-4659 (2008).
    • (2008) Medical Physics , vol.35 , Issue.10 , pp. 4649-4659
    • Leng, S.1    Zambelli, J.2
  • 6
    • 66849138632 scopus 로고    scopus 로고
    • GPU-accelerated SART reconstruction using the CUDA programming environment
    • Keck, B., Hofmann, H., Scherl, H., Kowarschik, M., "GPU-accelerated SART reconstruction using the CUDA programming environment," Proc. SPIE 7258, 72582B (2009).
    • (2009) Proc. SPIE , vol.7258
    • Keck, B.1    Hofmann, H.2    Scherl, H.3    Kowarschik, M.4
  • 8
    • 0242592238 scopus 로고    scopus 로고
    • Acceleration techniques for GPU-based volume rendering
    • Krüger, J. and Westermann, R., "Acceleration techniques for GPU-based volume rendering," Proc. IEEE Visualization, 287-292 (2003).
    • (2003) Proc. IEEE Visualization , pp. 287-292
    • Krüger, J.1    Westermann, R.2
  • 9
    • 79955760391 scopus 로고    scopus 로고
    • developer.download.nvidia.com/compute/cuda/sdk/website/samples.html
    • developer.download.nvidia.com/compute/cuda/sdk/website/samples.html
  • 10
    • 33750931235 scopus 로고    scopus 로고
    • A comparative study of popular interpolation and integration methods for use in computed tomography
    • 1625152, 2006 3rd IEEE International Symposium on Biomedical Imaging: From Nano to Macro - Proceedings
    • Xu, F. and Mueller, K., "A comparative study of popular interpolation and integration methods for use in computed tomography," IEEE International Symposium on Biomedical Imaging, 1252-1255 (2006). (Pubitemid 44732552)
    • (2006) 2006 3rd IEEE International Symposium on Biomedical Imaging: From Nano to Macro - Proceedings , vol.2006 , pp. 1252-1255
    • Xu, F.1    Mueller, K.2
  • 11
    • 0022920246 scopus 로고
    • 3-D reconstruction of the heart from few projections: A practical implementation of the McKinnon-Bates algorithm
    • Garden, K.L. and Robb, R.A., "3-D reconstruction of the heart from few projections: a practical implementation of the McKinnon-Bates algorithm," IEEE Trans Medical Imaging 5(4), 233-239 (1986).
    • (1986) IEEE Trans Medical Imaging , vol.5 , Issue.4 , pp. 233-239
    • Garden, K.L.1    Robb, R.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.