메뉴 건너뛰기




Volumn , Issue , 2011, Pages 1873-1880

Un-terminated, low-frequency terminal behavioral model of dc-dc converters

Author keywords

behavioral model; decoupling; electronic power converters; un terminated transfer functions

Indexed keywords

BEHAVIORAL MODEL; BLACK BOXES; DECOUPLING; ELECTRONIC POWER CONVERTERS; ENGINEERING PRACTICES; FREQUENCY RESPONSE CHARACTERISTIC; HIGH BANDWIDTH; LOAD DYNAMICS; LOW FREQUENCY; MODEL MATRICES; ON-LINE IDENTIFICATION; UN-TERMINATED TRANSFER FUNCTIONS; VERIFICATION AND VALIDATION; VOLTAGE SOURCE;

EID: 79955770196     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/APEC.2011.5744851     Document Type: Conference Paper
Times cited : (23)

References (20)
  • 1
    • 0003042842 scopus 로고
    • Input filter considerations in design and application of switching regulators
    • R. D. Middlebrook, "Input filter considerations in design and application of switching regulators," IEEE IAS '76, pp. 366-382, 1976.
    • (1976) IEEE IAS '76 , pp. 366-382
    • Middlebrook, R.D.1
  • 2
    • 0033879256 scopus 로고    scopus 로고
    • On-line measurement of stability margin of dc distributed power system
    • Mar.
    • X. Feng and F. C. Lee, "On-line measurement of stability margin of dc distributed power system," IEEE APEC '00, vol. 2, pp. 1190-1196, Mar. 2000.
    • (2000) IEEE APEC '00 , vol.2 , pp. 1190-1196
    • Feng, X.1    Lee, F.C.2
  • 3
    • 0242443744 scopus 로고    scopus 로고
    • Stability margin monitoring for dc distributed power systems via perturbation approaches
    • Nov.
    • J. Liu, X. Feng, F. C. Lee, and D. Boroyevich, "Stability margin monitoring for dc distributed power systems via perturbation approaches," IEEE Trans. Power Elec., vol. 18, no. 6, pp. 1254-1261, Nov. 2003.
    • (2003) IEEE Trans. Power Elec. , vol.18 , Issue.6 , pp. 1254-1261
    • Liu, J.1    Feng, X.2    Lee, F.C.3    Boroyevich, D.4
  • 4
    • 34748825177 scopus 로고    scopus 로고
    • Non-characteristic line harmonics of PWM ac-dc converters
    • Oct.
    • A. D. Graham, "Non-characteristic line harmonics of PWM ac-dc converters," Proc. Harmonics and Quality of Power., vol. 3, pp. 955-960, Oct. 2000.
    • (2000) Proc. Harmonics and Quality of Power , vol.3 , pp. 955-960
    • Graham, A.D.1
  • 6
    • 34748890706 scopus 로고    scopus 로고
    • Black-box terminal characterization modeling of dc-to-dc converters
    • Feb.
    • L. Arnedo, R. Burgos, F. Wang, and D. Boroyevich, "Black-box terminal characterization modeling of dc-to-dc converters," IEEE APEC '07, pp. 457-463, Feb. 2007.
    • (2007) IEEE APEC '07 , pp. 457-463
    • Arnedo, L.1    Burgos, R.2    Wang, F.3    Boroyevich, D.4
  • 10
    • 34748906165 scopus 로고    scopus 로고
    • Modular-terminal-behavioral (MTB) model for characterizing switching module conducted EMI generation in converter systems
    • Nov.
    • Q. Liu, F. Wang, and D. Boroyevich, "Modular-terminal-behavioral (MTB) model for characterizing switching module conducted EMI generation in converter systems," IEEE Trans. on Power Electronics, vol. 21, no. 6, pp. 1804-1814, Nov. 2006.
    • (2006) IEEE Trans. on Power Electronics , vol.21 , Issue.6 , pp. 1804-1814
    • Liu, Q.1    Wang, F.2    Boroyevich, D.3
  • 14
    • 0024056608 scopus 로고
    • Two-part characterization of PWM voltage regulators at low frequencies
    • P. G. Maranesi, et al., "Two-part characterization of PWM voltage regulators at low frequencies," Industrial Electronics, IEEE Transactions on, vol. 35, pp. 444-450, 1988.
    • (1988) Industrial Electronics, IEEE Transactions on , vol.35 , pp. 444-450
    • Maranesi, P.G.1
  • 15
    • 79955750438 scopus 로고    scopus 로고
    • www.agilent.com
  • 17
    • 79955779987 scopus 로고    scopus 로고
    • www.vicr.com
  • 18
    • 0023288306 scopus 로고
    • Necessary and sufficient conditions for balancing unstable systems
    • C. Kenney and G. Hewer, "Necessary and sufficient conditions for balancing unstable systems," Automatic Control, IEEE Transactions on, vol. 32, pp. 157-160, 1987.
    • (1987) Automatic Control, IEEE Transactions on , vol.32 , pp. 157-160
    • Kenney, C.1    Hewer, G.2
  • 19
    • 0001098633 scopus 로고
    • Singular perturbation method for reducing the model order in optimal control design
    • P. Kokotovic and P. Sannuti, "Singular perturbation method for reducing the model order in optimal control design," Automatic Control, IEEE Transactions on, vol. 13, pp. 377-384, 1968.
    • (1968) Automatic Control, IEEE Transactions on , vol.13 , pp. 377-384
    • Kokotovic, P.1    Sannuti, P.2
  • 20
    • 79955754365 scopus 로고    scopus 로고
    • www.mathworks.com


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.