Volumn 27, Issue 5, 2011, Pages 445-449

Usage of 64-detector-row spiral computed tomography volumetry in preoperative volume prediction in living donor liver transplantation in children

Author keywords

64 Detector row spiral CT; Children; Liver volumetry; Living donor liver transplantation

Indexed keywords

ADULT; ARTICLE; CORRELATION ANALYSIS; FEMALE; HUMAN; IMAGE PROCESSING; INTRAOPERATIVE PERIOD; LIVER GRAFT; LIVER TRANSPLANTATION; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; ORGAN DONOR; PREOPERATIVE PERIOD; PRIORITY JOURNAL; VOLUMETRY;

EID: 79955739189     PISSN: 01790358     EISSN: 14379813     Source Type: Journal    
DOI: 10.1007/s00383-010-2830-z     Document Type: Article
Times cited : (10)

References (22)
  • 1
    • 33845605014 scopus 로고    scopus 로고
    • Liver transplantation in children
    • DOI 10.1016/j.jhep.2006.11.006, PII S0168827806006325
    • P Muiesan D Vergani GL Mieli-Vergani 2007 Liver transplantaton in children J Hepatol 46 340 348 17161491 10.1016/j.jhep.2006.11.006 (Pubitemid 44959166)
    • (2007) Journal of Hepatology , vol.46 , Issue.2 , pp. 340-348
    • Muiesan, P.1    Vergani, D.2    Mieli-Vergani, G.3
  • 2
    • 0034049077 scopus 로고    scopus 로고
    • Right lobe living donor liver transplantation: A review
    • A Marcos 2000 Right lobe living donor liver transplantation: a review Liver Transpl 6 3 20 10648573 1:STN:280:DC%2BD3c7mslClsQ%3D%3D (Pubitemid 30123363)
    • (2000) Liver Transplantation , vol.6 , Issue.1 , pp. 3-20
    • Marcos, A.1
  • 3
    • 37849005926 scopus 로고    scopus 로고
    • Imaging evaluation of potential donors in living donor liver transplantation
    • 18194688 10.1016/j.crad.2007.08.008 1:STN:280:DC%2BD1c%2FktVKmtA%3D%3D
    • G Low E Wiebe AH Walji, et al. 2008 Imaging evaluation of potential donors in living donor liver transplantation Clin Radiol 63 136 145 18194688 10.1016/j.crad.2007.08.008 1:STN:280:DC%2BD1c%2FktVKmtA%3D%3D
    • (2008) Clin Radiol , vol.63 , pp. 136-145
    • Low, G.1    Wiebe, E.2    Walji, A.H.3
  • 4
    • 49749150484 scopus 로고    scopus 로고
    • Preoperative volume prediction in adult live donor liver transplantation: 3-D CT volumetry approach to prevent miscalculations
    • A Radtki GC Sotiropoulos S Nadalin, et al. 2008 Preoperative volume prediction in adult live donor liver transplantation: 3-D CT volumetry approach to prevent miscalculations Eur J Med Res 13 319 326
    • (2008) Eur J Med Res , vol.13 , pp. 319-326
    • Radtki, A.1    Sotiropoulos, G.C.2    Nadalin, S.3
  • 9
    • 0031044390 scopus 로고    scopus 로고
    • CT volumetry of the liver before transplantation
    • 9072098 1:STN:280:DyaK2s3gsFKjsQ%3D%3D
    • AJ Lemke N Hosten K Neumann, et al. 1997 CT volumetry of the liver before transplantation Rofo 166 1 18 23 9072098 1:STN:280:DyaK2s3gsFKjsQ%3D%3D
    • (1997) Rofo , vol.166 , Issue.1 , pp. 18-23
    • Lemke, A.J.1    Hosten, N.2    Neumann, K.3
  • 11
    • 0036311793 scopus 로고    scopus 로고
    • Potential living liver donors: Evaluation with an all-in-one protocol with multi-detector row CT
    • T Schroeder S Nadalin J Stattaus, et al. 2002 Potential living liver donors: evaluation with all-in-one protocol with multi-director row CT Radiology 224 586 591 12147860 10.1148/radiol.2242011340 (Pubitemid 34809145)
    • (2002) Radiology , vol.224 , Issue.2 , pp. 586-591
    • Schroeder, T.1    Nadalin, S.2    Stattaus, J.3    Debatin, J.F.4    Malago, M.5    Ruehm, S.G.6
  • 13
    • 0034986692 scopus 로고    scopus 로고
    • Right lobe living donor liver transplantation: Preoperative evaluation of the donor with MR imaging
    • 11373218 1:STN:280:DC%2BD3MzhsFelug%3D%3D
    • A Fulcher R Szucs M Bassignani, et al. 2001 Right lobe living donor liver transplantation: preoperative evaluation of the donor with MR imaging AJR Am J Roentgenol 176 1483 1485 11373218 1:STN:280:DC%2BD3MzhsFelug%3D%3D
    • (2001) AJR Am J Roentgenol , vol.176 , pp. 1483-1485
    • Fulcher, A.1    Szucs, R.2    Bassignani, M.3
  • 14
    • 22144482339 scopus 로고    scopus 로고
    • "All-in-one" imaging protocols for the evaluation of potential living liver donors: Comparison of magnetic resonance imaging and multidetector computed tomography
    • DOI 10.1002/lt.20429
    • T Schroeder M Malago JF Debatin, et al. 2005 All-in one imaging protocols for the evaluation of potential living liver donors: comparison of Magnetic resonance imaging and multidetector computed tomography Liver Transpl 11 776 778 15973711 10.1002/lt.20429 (Pubitemid 40975579)
    • (2005) Liver Transplantation , vol.11 , Issue.7 , pp. 776-787
    • Schroeder, T.1    Malago, M.2    Debatin, J.F.3    Goyen, M.4    Nadalin, S.5    Ruehm, S.G.6
  • 15
    • 0036201188 scopus 로고    scopus 로고
    • Right-lobe living related liver transplantation: Evaluation of a comprehensive magnetic resonance imaging protocol for assessing potential donors
    • DOI 10.1053/jlts.2002.30403
    • M Goyen J Barkhausen JF Debatin, et al. 2002 Right-Lobe living related living transplantation: evaluation of a comprehensive magnetic resonance imaging protocol for assessing potential donors Liver Transpl 8 241 250 11910569 10.1053/jlts.2002.30403 (Pubitemid 34257206)
    • (2002) Liver Transplantation , vol.8 , Issue.3 , pp. 241-250
    • Goyen, M.1    Barkhausen, J.2    Debatin, J.F.3    Kuhl, H.4    Bosk, S.5    Testa, G.6    Malago, M.7    Ruehm, S.G.8
  • 16
    • 0035958120 scopus 로고    scopus 로고
    • Graft size assessment and analysis of donors for living donor liver transplantation using right lobe
    • S Sakamoto S Uemoto K Uryuhara, et al. 2001 Graft size assessment and analysis of donors for living donor liver transplantation using right lobe Transplantation 71 1407 1413 11391227 10.1097/00007890-200105270-00009 1:STN:280:DC%2BD3MzitVOmsw%3D%3D (Pubitemid 32507113)
    • (2001) Transplantation , vol.71 , Issue.10 , pp. 1407-1413
    • Sakamoto, S.1    Uemoto, S.2    Uryuhara, K.3    Kim, I.-D.4    Kiuchi, T.5    Egawa, H.6    Inomata, Y.7    Tanaka, K.8
  • 18
    • 0036905541 scopus 로고    scopus 로고
    • Correlation of blood-free graft weight and volumetric graft volume by an analysis of blood content in living donor liver grafts
    • DOI 10.1016/S0041-1345(02)03603-5, PII S0041134502036035
    • S Hwang SG Lee KH Kim, et al. 2002 Correlation of blood-free weight and volumetric graft volume by analysis of blood content in living donor liver transplantation Transplant Proc 34 3293 3297 12493450 10.1016/S0041-1345(02) 03603-5 1:STN:280:DC%2BD38jjtFGqtw%3D%3D (Pubitemid 35463323)
    • (2002) Transplantation Proceedings , vol.34 , Issue.8 , pp. 3293-3294
    • Hwang, S.1    Lee, S.G.2    Kim, K.H.3    Park, K.M.4    Ahn, C.S.5    Moon, D.B.6    Chu, C.W.7    Lee, Y.J.8    Min, P.C.9
  • 19
    • 33747586320 scopus 로고    scopus 로고
    • Living donor right liver lobes: Preoperative CT volumetric measurement for calculation of intraoperative weight and volume
    • DOI 10.1148/radiol.2403042062
    • AJ Lemke MJ Brinkmann T Schott, et al. 2006 Living donor right liver lobes: preoperative CT volumetric measurement for calculation of intraoperative weight and volume Radiology 240 3 736 742 16868277 10.1148/radiol.2403042062 (Pubitemid 44267329)
    • (2006) Radiology , vol.240 , Issue.3 , pp. 736-742
    • Lemke, A.-J.1    Brinkmann, M.J.2    Schott, T.3    Niehues, S.M.4    Settmacher, U.5    Neuhaus, P.6    Felix, R.7
  • 20
    • 0035144299 scopus 로고    scopus 로고
    • Accuracy of volumetric measurements after virtual right hepatectomy in potential donors undergoing living adult liver transplantation
    • I Kamel J Kruskal G Warmbrand, et al. 2001 Accuracy of volumetric measurements after virtual right hepatectomy in potential donors undergoing living adult liver transplantation AJR Am J Roentgenol 176 483 487 11159100 1:STN:280:DC%2BD3M3isVajuw%3D%3D (Pubitemid 32105666)
    • (2001) American Journal of Roentgenology , vol.176 , Issue.2 , pp. 483-487
    • Kamel, I.R.1    Kruskal, J.B.2    Warmbrand, G.3    Goldberg, S.N.4    Pomfret, E.A.5    Raptopoulos, V.6