Volumn , Issue , 2010, Pages 138-142

Knee joint cartilage visualization and quantification in normal and osteoarthritis

Author keywords

Cartilage; Knee joint; MRI; Segmentation

Indexed keywords

ARTICULAR CARTILAGES; CANNY EDGE DETECTION; CARTILAGE THICKNESS; HISTOGRAM EQUALIZATIONS; HUMAN BODIES; IMAGE PROCESSING TECHNIQUE; KNEE JOINT; MAGNETIC RESONANCE IMAGES; MRI; REGION OF INTEREST; SEGMENTATION; SEMIAUTOMATIC METHODS; THRESHOLDING;

EID: 79955700063     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICSMB.2010.5735360     Document Type: Conference Paper
Times cited : (18)

References (12)
  • 2
    • 79955677242 scopus 로고    scopus 로고
    • National Institutes of Health (NIH), Department of Health and Human Services, Publication 06-4617 May
    • National Institutes of Health (NIH), 'Handout on Health', Department of Health and Human Services, Publication No. 06- 4617, May 2006.
    • (2006) Handout on Health
  • 3
    • 84874563410 scopus 로고    scopus 로고
    • The definition of a successfol total knee replacement differs for asian and european patients current outcomes and quality of life assessments do not consider cultural variations
    • July/August
    • Bharat S. Mody, The Definition of a Successfol Total Knee Replacement Differs for Asian and European Patients Current Outcomes and Quality of Life Assessments do not consider Cultural Variations. Orthopedics Today Europe July/August 20 I O.
    • (2010) Orthopedics Today Europe
    • Mody, B.S.1
  • 5
    • 33646344735 scopus 로고    scopus 로고
    • Suiface extraction and thickness measurement of the articular Cartilage from MR images using Directional Gradient Vector Flow Snakes
    • May
    • Jinshan Tang, Steven Millington, Scott T. Acton, Jeff Crandall, and Shepard Hurwitz, Suiface Extraction and Thickness Measurement of the Articular Cartilage from MR images using Directional Gradient Vector Flow Snakes, IEEE Transactions on Biomedical Engineering, Vol. 53, No.5, May 2006.
    • (2006) IEEE Transactions on Biomedical Engineering , vol.53 , Issue.5
    • Tang, J.1    Millington, S.2    Acton, S.T.3    Crandall, J.4    Hurwitz, S.5
  • 8
    • 66149116027 scopus 로고    scopus 로고
    • Knee Cartilage: Efficient and reproducible segmentation on high- spatial-resolution MR images with the semiautomated graph-cut algorithm method
    • May
    • Hackjoon Shim, Samuel Chang,Cheng Tao,Jin-Hong Wang,C. Kent Kwoh, Kyongtae T. Bae, Knee Cartilage: Efficient and Reproducible Segmentation on High- Spatial-Resolution MR images with the Semiautomated Graph-Cut Algorithm Method/, Radiology: Vol. 251: No.2, May 2009.
    • (2009) Radiology , vol.251 , Issue.2
    • Shim, H.1    Chang, S.2    Tao, C.3    Wang, J.4    Kwoh, C.K.5    Bae, K.T.6
  • 9
    • 0033028923 scopus 로고    scopus 로고
    • Knee cartilage topography, thickness, and contact areas from MRI: In- vitro calibration and in-vivo measurements
    • DOI 10.1053/joca.1998.0165
    • Zohara A. Cohen, Denise M. Mccarthy, S. Daniel K wak, Perrine Legrand, Fabian Fogarasi, Edward 1. Ciaccio And Gerard A. Ateshian, Knee Cartilage Topography, Thickness, and Contact Areas from MRI : In-vitro Calibration and in-vivo Measurements, Osteoarthritis and Cartilage,7, 95-109, 1999 (Pubitemid 29112963)
    • (1999) Osteoarthritis and Cartilage , vol.7 , Issue.1 , pp. 95-109
    • Cohen, Z.A.1    McCarthy, D.M.2    Kwak, S.D.3    Legrand, P.4    Fogarasi, F.5    Ciaccio, E.J.6    Ateshian, G.A.7
  • 12


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.