메뉴 건너뛰기




Volumn , Issue , 2017, Pages

An equivalent circuit of a transmission-line tower struck by lightning

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC LINES; FINITE DIFFERENCE TIME DOMAIN METHOD; LIGHTNING; LIGHTNING PROTECTION; MAXWELL EQUATIONS; TIME DOMAIN ANALYSIS; TIMING CIRCUITS; TRANSMISSION LINE THEORY;

EID: 79955671288     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICLP.2010.7845761     Document Type: Conference Paper
Times cited : (7)

References (14)
  • 2
    • 84894021661 scopus 로고
    • Numerical solution of initial boundary value problems involving Maxwell's equations in isotropic media
    • Aug.
    • K. S. Yee, "Numerical solution of initial boundary value problems involving Maxwell's equations in isotropic media", IEEE Trans. Antennas and Propagation, Vol. 14, No. 8, pp. 302-307, Aug. 1966.
    • (1966) IEEE Trans. Antennas and Propagation , vol.14 , Issue.8 , pp. 302-307
    • Yee, K.S.1
  • 3
    • 0034223748 scopus 로고    scopus 로고
    • Numerical Electromagnetic field analysis on lightning surge response of tower with shield wire
    • Jul.
    • Y. Baba, and M. Ishii, "Numerical Electromagnetic field analysis on lightning surge response of tower with shield wire", IEEE Trans. Power Delivery, Vol. 15, No. 3, pp. 1010-1015, Jul. 2000.
    • (2000) IEEE Trans. Power Delivery , vol.15 , Issue.3 , pp. 1010-1015
    • Baba, Y.1    Ishii, M.2
  • 4
    • 0037247320 scopus 로고    scopus 로고
    • Numerical Electromagnetic field analysis of archorn voltages during a back-tlashover on a 500 kV twin-circuit line
    • Jan.
    • T. Mozumi, Y. Baba, M. Ishii, N. Nagaoka, and A. Ametani, "Numerical Electromagnetic field analysis of archorn voltages during a back-tlashover on a 500 kV twin-circuit line", IEEE Trans. Power Delivery, Vol. 18, No. l, pp. 207-213, Jan. 2003.
    • (2003) IEEE Trans. Power Delivery , vol.18 , Issue.1 , pp. 207-213
    • Mozumi, T.1    Baba, Y.2    Ishii, M.3    Nagaoka, N.4    Ametani, A.5
  • 5
    • 34447297861 scopus 로고    scopus 로고
    • Improvements of an FDTD-based surge simulation code and its application to the lightning overvoltage calculation of a transmission tower
    • T. Noda, A. Tatematsu, and S. Yokoyama, "Improvements of an FDTD-based surge simulation code and its application to the lightning overvoltage calculation of a transmission tower", Electric Power System Research, Vol. 77, pp. 1495-1500, 2007.
    • (2007) Electric Power System Research , vol.77 , pp. 1495-1500
    • Noda, T.1    Tatematsu, A.2    Yokoyama, S.3
  • 7
    • 0012886008 scopus 로고
    • Bonneville Power Administration, Portland Oregon
    • W. Scott-Meyer, "EMTP rule book", Bonneville Power Administration, Portland Oregon, 1977.
    • (1977) EMTP Rule Book
    • Scott-Meyer, W.1
  • 8
    • 33847735038 scopus 로고    scopus 로고
    • A tower model for lightning overvoltage studies based on the result of an FDTD simulation (in Japanese)
    • Feb
    • T. Noda, "A tower model for lightning overvoltage studies based on the result of an FDTD simulation" (in Japanese), IEEJ Trans. Power and Energy, Vol. 127, No. 2, pp. 379-388, Feb 2007.
    • (2007) IEEJ Trans. Power and Energy , vol.127 , Issue.2 , pp. 379-388
    • Noda, T.1
  • 9
    • 0021510599 scopus 로고
    • A transmitting boundary for transient wave analysis
    • Z. P. Liao, H. L. Wong, B.-Po Yang, and Y.-F. Yuan, "A transmitting boundary for transient wave analysis", Science Sinica, Vol. A27, No. 10, pp. 1063-1076, 1984.
    • (1984) Science Sinica , vol.27 , Issue.10 , pp. 1063-1076
    • Liao, Z.P.1    Wong, H.L.2    Yang, B.-P.3    Yuan, Y.-F.4
  • 10
    • 27644568519 scopus 로고    scopus 로고
    • On the mechanism of attenuation of current waves propagating along a vertical perfectly conducting wire above ground: Application to lightning
    • Aug.
    • Y. Baba, and V. A. Rakov, "On the mechanism of attenuation of current waves propagating along a vertical perfectly conducting wire above ground: application to lightning", IEEE Trans. Electromagnetic Compatibility, Vol. 47, No. 3, pp. 521-532, Aug. 2005.
    • (2005) IEEE Trans. Electromagnetic Compatibility , vol.47 , Issue.3 , pp. 521-532
    • Baba, Y.1    Rakov, V.A.2
  • 11
    • 27644446880 scopus 로고    scopus 로고
    • On the interpretation of ground reflections observed in small-scale experiments simulating lightning strikes to towers
    • Aug.
    • Y. Baba, and V. A. Rakov, "On the interpretation of ground reflections observed in small-scale experiments simulating lightning strikes to towers", IEEE Trans. Electromagnetic Compatibility, Vol. 47, No. 3, pp. 533-542 Aug. 2005.
    • (2005) IEEE Trans. Electromagnetic Compatibility , vol.47 , Issue.3 , pp. 533-542
    • Baba, Y.1    Rakov, V.A.2
  • 12
    • 33847757747 scopus 로고
    • Fieldtest result of the lightning-surge response of a 500-kV transmiSSIOn line
    • (in Japanese)
    • H. Matsubara, H. Motoyama, and K. Wakamatsu, "Fieldtest result of the lightning-surge response of a 500-kV transmiSSIOn line" (in Japanese), IEEJ National Convention Record, no. 1237, 1989.
    • (1989) IEEJ National Convention Record , Issue.1237
    • Matsubara, H.1    Motoyama, H.2    Wakamatsu, K.3
  • 13
    • 42249104494 scopus 로고    scopus 로고
    • A numerical simulation of transient Electromagnetic fields for obtaining the step response of a transmission tower using the FDTD method
    • Apr.
    • T. Noda, "A numerical simulation of transient Electromagnetic fields for obtaining the step response of a transmission tower using the FDTD method", IEEE Trans. Power Delivery, Vol. 23, No. 2, pp. 1262-1263, Apr. 2008.
    • (2008) IEEE Trans. Power Delivery , vol.23 , Issue.2 , pp. 1262-1263
    • Noda, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.