-
1
-
-
0026045253
-
Non-union of fractures of the midshaft of the clavicle
-
Boehme, D., Curtis, R.J., DeHaan, J.T., 1991. Non-union of fractures of the midshaft of the clavicle. J Bone Joint Surg Am 73, 1219-1226.
-
(1991)
J Bone Joint Surg Am
, vol.73
, pp. 1219-1226
-
-
Boehme, D.1
Curtis, R.J.2
DeHaan, J.T.3
-
2
-
-
0000236733
-
Complications of plate fixation in fresh displaced midclavicular fractures
-
Böstman, O., Manninen, M., Pihlajamäki, H., 1997. Complications of plate fixation in fresh displaced midclavicular fractures. J Trauma 43 (5), 778-783. (Pubitemid 27513747)
-
(1997)
Journal of Trauma - Injury, Infection and Critical Care
, vol.43
, Issue.5
, pp. 778-783
-
-
Bostman, O.1
Manninen, M.2
Pihlajamaki, H.3
-
3
-
-
79955662300
-
Clinical results of clavicle fracture using J plate
-
Bungo, O., Nakayama, I., Hasebe, K., Oda, Y., Goto, K., Hata, K., et al., 2002. Clinical results of clavicle fracture using J plate. Orthop Traumatol 51 (1), 96-99.
-
(2002)
Orthop Traumatol
, vol.51
, Issue.1
, pp. 96-99
-
-
Bungo, O.1
Nakayama, I.2
Hasebe, K.3
Oda, Y.4
Goto, K.5
Hata, K.6
-
4
-
-
42049088290
-
Biomechanical evaluation of clavicle fracture plating techniques: Does a locking plate provide improved stability?
-
Celestre, P., Roberston, C., Mahar, A., Oka, R., Meunier, M., Schwartz, A., 2008. Biomechanical evaluation of clavicle fracture plating techniques: does a locking plate provide improved stability? J Orthop Trauma 22 (4), 241-247.
-
(2008)
J Orthop Trauma
, vol.22
, Issue.4
, pp. 241-247
-
-
Celestre, P.1
Roberston, C.2
Mahar, A.3
Oka, R.4
Meunier, M.5
Schwartz, A.6
-
5
-
-
0033162492
-
Clavicle malunion
-
Chan, K.Y., Jupiter, J.B., Leffert, R.D., Marti, R., 1999. Clavicle malunion. J Shoulder Elbow Surg 8, 287-290.
-
(1999)
J Shoulder Elbow Surg
, vol.8
, pp. 287-290
-
-
Chan, K.Y.1
Jupiter, J.B.2
Leffert, R.D.3
Marti, R.4
-
6
-
-
33751055846
-
Anterior-inferior plate fixation of middle-third fractures and nonunions of the clavicle
-
Collinge, C., Devinney, S., Herscovici, D., DiPasquale, T., Sanders, R., 2006. Anterior-inferior plate fixation of middle-third fractures and nonunions of the clavicle. J Orthop Trauma 20 (10), 680-686.
-
(2006)
J Orthop Trauma
, vol.20
, Issue.10
, pp. 680-686
-
-
Collinge, C.1
Devinney, S.2
Herscovici, D.3
DiPasquale, T.4
Sanders, R.5
-
7
-
-
33846052672
-
Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. A multicenter, randomized clinical trial
-
COTS, C.O.T.S.
-
COTS, C.O.T.S., 2007. Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. A multicenter, randomized clinical trial. J Bone Joint Surg Am 89 (1), 1-10.
-
(2007)
J Bone Joint Surg Am
, vol.89
, Issue.1
, pp. 1-10
-
-
-
8
-
-
26444439066
-
A new approach for plate fixation of midshaft clavicular fractures
-
DOI 10.1016/j.injury.2005.03.007, PII S0020138305000902
-
Coupe, B.D., Wimhurst, J.A., Indar, R., Calder, D.A., Patel, A.D., 2005. A new approach for plate fixation of midshaft clavicular fractures. Injury 36 (10), 1166-1171. (Pubitemid 41433273)
-
(2005)
Injury
, vol.36
, Issue.10
, pp. 1166-1171
-
-
Coupe, B.D.1
Wimhurst, J.A.2
Indar, R.3
Calder, D.A.4
Patel, A.D.5
-
9
-
-
33751209188
-
Analysis of musculoskeletal systems in the AnyBody Modeling System
-
DOI 10.1016/j.simpat.2006.09.001, PII S1569190X06000554
-
Damsgaard, M., Rasmussen, J., Tørholm Christensen, S., Surma, E., de Zee, M., 2006. Analysis of musculoskeletal systems in the AnyBody Modeling System. Simul Model Pract Theory 14 (8), 1100-1111. (Pubitemid 44792560)
-
(2006)
Simulation Modelling Practice and Theory
, vol.14
, Issue.8
, pp. 1100-1111
-
-
Damsgaard, M.1
Rasmussen, J.2
Christensen, S.T.3
Surma, E.4
De Zee, M.5
-
10
-
-
79955648180
-
-
Thieme Medical Publishers, New York
-
Dines, D.M., Lorich, D.G., Helfet, D., 2008. Solutions for Complex Upper Extremity Trauma. Thieme Medical Publishers, New York.
-
(2008)
Solutions for Complex Upper Extremity Trauma
-
-
Dines, D.M.1
Lorich, D.G.2
Helfet, D.3
-
11
-
-
48849083805
-
A biomechanical study of plate versus intramedullary devices for midshaft clavicle fixation
-
Golish, S.R., Oliviero, J.A., Francke, E.I., Miller, M.D., 2008. A biomechanical study of plate versus intramedullary devices for midshaft clavicle fixation. J Orthop Surg Res 3, 28.
-
(2008)
J Orthop Surg Res
, vol.3
, pp. 28
-
-
Golish, S.R.1
Oliviero, J.A.2
Francke, E.I.3
Miller, M.D.4
-
12
-
-
0030200943
-
Biomechanical aspects of plating osteosynthesis of transverse clavicular fracture with and without inferior cortical defect
-
DOI 10.1016/0268-0033(96)00001-0
-
Harnroongroj, T., Vanadurongwan, V., 1996. Biomechanical aspects of plating osteosynthesis of transverse clavicular fracture with and without inferior cortical defect. Clin Biomech 11 (5), 290-294. (Pubitemid 26235698)
-
(1996)
Clinical Biomechanics
, vol.11
, Issue.5
, pp. 290-294
-
-
Harnroongroj, T.1
Vanadurongwan, V.2
-
13
-
-
0027575821
-
Geometric properties and the predicted mechanical behavior of adult human clavicles
-
Harrington, M.A.J., Keller, T.S., Seiler, J.G.r., Weikert, D.R., Moeljanto, E., Schwartz, H.S., 1993. Geometric properties and the predicted mechanical behavior of adult human clavicles. J Biomech 26 (4-5), 417-426.
-
(1993)
J Biomech
, vol.26
, Issue.4-5
, pp. 417-426
-
-
Harrington, M.A.J.1
Keller, T.S.2
Seiler, J.G.R.3
Weikert, D.R.4
Moeljanto, E.5
Schwartz, H.S.6
-
14
-
-
0030785720
-
Closed treatment of displaced middle-third fractures of the clavicle gives poor results
-
Hill, J.M., McGuire, M.H., Crosby, L.A., 1997. Closed treatment of displaced middle-third fractures of the clavicle gives poor results. J Bone Joint Surg Br 79, 537-539.
-
(1997)
J Bone Joint Surg Br
, vol.79
, pp. 537-539
-
-
Hill, J.M.1
McGuire, M.H.2
Crosby, L.A.3
-
15
-
-
0041346511
-
Effects of plate location and selection on the stability of midshaft clavicle osteotomies: A biomechanical study
-
DOI 10.1067/mse.2002.125805
-
Iannotti, M.R., Crosby, L.A., Stafford, P., Grayson, G., Goulet, R., 2002. Effects of plate location and selection on the stability of midshaft clavicle osteotomies: a biomechanical study. J Shoulder Elbow Surg 11 (5), 457-462. (Pubitemid 36904207)
-
(2002)
Journal of Shoulder and Elbow Surgery
, vol.11
, Issue.5
, pp. 457-462
-
-
Iannotti, M.R.1
Crosby, L.A.2
Stafford, P.3
Grayson, G.4
Goulet, R.5
-
17
-
-
11244272783
-
Bilateral clavicle non-unions treated with anteroinferior locking compression plating (LCP): A case report
-
Kloen, P., 2004. Bilateral clavicle non-unions treated with anteroinferior locking compression plating (LCP): a case report. Acta Orthop Belg 70 (6), 609-611. (Pubitemid 40069799)
-
(2004)
Acta Orthopaedica Belgica
, vol.70
, Issue.6
, pp. 609-611
-
-
Kloen, P.1
-
18
-
-
0036065856
-
Anteroinferior plating of midshaft clavicular nonunions
-
DOI 10.1097/00005131-200207000-00011
-
Kloen, P., Sorkin, A.T., Rubel, I.F., Helfet, D.L., 2002. Anteroinferior plating of midshaft clavicular nonunions. J Orthop Trauma 16 (6), 425-430. (Pubitemid 34785162)
-
(2002)
Journal of Orthopaedic Trauma
, vol.16
, Issue.6
, pp. 425-430
-
-
Kloen, P.1
Sorkin, A.T.2
Rubel, I.F.3
Helfet, D.L.4
-
19
-
-
0038272861
-
Symptomatic malunions of the middle clavicle
-
Kuhn, J.E., 1999. Symptomatic malunions of the middle clavicle. J Shoulder Elbow Surg 8, 539.
-
(1999)
J Shoulder Elbow Surg
, vol.8
, pp. 539
-
-
Kuhn, J.E.1
-
20
-
-
22144464816
-
Short malunions of the clavicle: An anatomic and functional study
-
DOI 10.1016/j.jse.2004.09.011, PII S1058274604002678
-
Ledger, M., Leeks, N., Ackland, T., Wang, A., 2005. Short malunions of the clavicle: an anatomic and functional study. J Shoulder Elbow Surg 14 (4), 349-354. (Pubitemid 40979645)
-
(2005)
Journal of Shoulder and Elbow Surgery
, vol.14
, Issue.4
, pp. 349-354
-
-
Ledger, M.1
Leeks, N.2
Ackland, T.3
Wang, A.4
-
21
-
-
0037657970
-
Midshaft malunions of the clavicle
-
McKee, M.D., Wild, L.M., Schemitsch, E.H., 2003. Midshaft malunions of the clavicle. J Bone Joint Surg Am 85, 790-797. (Pubitemid 36548624)
-
(2003)
Journal of Bone and Joint Surgery - Series A
, vol.85
, Issue.5
, pp. 790-797
-
-
McKee, M.D.1
Wild, L.M.2
Schemitsch, E.H.3
-
22
-
-
0027972687
-
Low-contact dynamic compression plating of the clavicle
-
DOI 10.1016/0020-1383(94)90183-X
-
Mullaji, A.B., Jupiter, J.B., 1994. Low-contact dynamic compression plating of the clavicle. Injury 25, 41-45. (Pubitemid 24014857)
-
(1994)
Injury
, vol.25
, Issue.1
, pp. 41-45
-
-
Mullaji, A.B.1
-
23
-
-
72849157960
-
Non-union of the clavicle
-
Neer, C.S.I., 1960. Non-union of the clavicle. J Am Med Assoc 172, 1006-1011.
-
(1960)
J Am Med Assoc
, vol.172
, pp. 1006-1011
-
-
Neer, C.S.I.1
-
24
-
-
67649099622
-
Surgical treatment of midclavicular fractures in the elderly: A comparison of locking and nonlocking plates
-
orthosupersite.com/view.asp?rID=38059
-
Pai, H.T., Lee, Y.S., Cheng, C.Y., 2009. Surgical treatment of midclavicular fractures in the elderly: a comparison of locking and nonlocking plates. Orthopedics 32 (4) orthosupersite.com/view.asp?rID=38059.
-
(2009)
Orthopedics
, vol.32
, Issue.4
-
-
Pai, H.T.1
Lee, Y.S.2
Cheng, C.Y.3
-
25
-
-
77956184073
-
Long-term Results of Conservative Management of Midshaft Clavicle Fracture
-
Epub ahead of print
-
Postacchini, R., Gumina, S., Farsetti, P., Postacchini, F., 2009. Long-term Results of Conservative Management of Midshaft Clavicle Fracture. Int Orthop, Epub ahead of print.
-
(2009)
Int Orthop
-
-
Postacchini, R.1
Gumina, S.2
Farsetti, P.3
Postacchini, F.4
-
26
-
-
58149191922
-
Management of clavicle fractures
-
Pujalte, G.G., Housner, J.A., 2008. Management of clavicle fractures. Curr Sports Med Rep 7 (5), 275-280.
-
(2008)
Curr Sports Med Rep
, vol.7
, Issue.5
, pp. 275-280
-
-
Pujalte, G.G.1
Housner, J.A.2
-
27
-
-
60649092513
-
Reconstruction plates for stabilization of mid-shaft clavicle fractures: Differences between nonlocked and locked plates in two different positions
-
Robertson, C., Celestre, P., Mahar, A., Schwartz, A., 2009. Reconstruction plates for stabilization of mid-shaft clavicle fractures: differences between nonlocked and locked plates in two different positions. J Shoulder Elbow Surg 18 (2), 204-209.
-
(2009)
J Shoulder Elbow Surg
, vol.18
, Issue.2
, pp. 204-209
-
-
Robertson, C.1
Celestre, P.2
Mahar, A.3
Schwartz, A.4
-
28
-
-
0014279915
-
An atlas of anatomy and treatment of midclavicular fractures
-
Rowe, C.R., 1968. An atlas of anatomy and treatment of midclavicular fractures. Clin Orthop Relat Res 58, 29-42.
-
(1968)
Clin Orthop Relat Res
, vol.58
, pp. 29-42
-
-
Rowe, C.R.1
-
29
-
-
0025281819
-
Normal functional range of motion of upper limb joints during performance of three feeding activities
-
Safaee-Rad, R., Shwedyk, E., Quanbury, A.O., Cooper, J.E., 1990. Normal functional range of motion of upper limb joints during performance of three feeding activities. Arch Phys Med Rehabil 71 (7), 505-509. (Pubitemid 20175710)
-
(1990)
Archives of Physical Medicine and Rehabilitation
, vol.71
, Issue.7
, pp. 505-509
-
-
Safaee-Rad, R.1
Shwedyk, E.2
Quanbury, A.O.3
Cooper, J.E.4
-
30
-
-
0026649014
-
Osteosynthesis of irreducible fractures of the clavicle with 2.7-mm ASIF plates
-
Schwarz, N., Hocker, K., 1992. Osteosynthesis of irreducible fractures of the clavicle with 2.7-mm ASIF plates. J Trauma 33, 179-183.
-
(1992)
J Trauma
, vol.33
, pp. 179-183
-
-
Schwarz, N.1
Hocker, K.2
-
31
-
-
67349098880
-
Shaft fractures of the clavicle: Current concepts
-
Smekal, V., Oberladstaetter, J., Struve, P., Krappinger, D., 2009. Shaft fractures of the clavicle: current concepts. Arch Orthop Trauma Surg 129 (6), 807-815.
-
(2009)
Arch Orthop Trauma Surg
, vol.129
, Issue.6
, pp. 807-815
-
-
Smekal, V.1
Oberladstaetter, J.2
Struve, P.3
Krappinger, D.4
-
32
-
-
79955643850
-
Treatment of midshaft clavicular delayed and non-unions with anteroinferior locking compression plating
-
Stufkens, S.A., Kloen, P., 2009. Treatment of midshaft clavicular delayed and non-unions with anteroinferior locking compression plating. Arch Orthop Trauma Surg.
-
(2009)
Arch Orthop Trauma Surg
-
-
Stufkens, S.A.1
Kloen, P.2
-
33
-
-
0026816651
-
Geometry parameters for musculoskeletal modelling of the shoulder system
-
Van der Helm, F.C., Veeger, H.E., Pronk, G.M., Van der Woude, L.H., Rozendal, R.H., 1992. Geometry parameters for musculoskeletal modelling of the shoulder system. J Biomech 25 (2), 129-144.
-
(1992)
J Biomech
, vol.25
, Issue.2
, pp. 129-144
-
-
Van Der Helm, F.C.1
Veeger, H.E.2
Pronk, G.M.3
Van Der Woude, L.H.4
Rozendal, R.H.5
|