메뉴 건너뛰기




Volumn 30, Issue 5, 2011, Pages 1017-1027

Signal compensation and compressed sensing for magnetization-prepared MR angiography

Author keywords

Angiography; compensation; compressed sensing; magnetic resonance imaging (MRI); magnetization preparation; signal decay

Indexed keywords

COMPENSATION; COMPRESSED SENSING; DATA COLLECTION; HIGH FREQUENCY DATA; HIGH-FREQUENCY NOISE; IMAGE BLURRING; IMAGE CONTRASTS; K-SPACE; LOWER EXTREMITY; MR ANGIOGRAPHY; NON LINEAR RECONSTRUCTION; RESOLUTION LOSS; SIGNAL COMPENSATION; SIGNAL DECAY; SPATIAL RESOLUTION;

EID: 79955620844     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2011.2116123     Document Type: Article
Times cited : (38)

References (52)
  • 1
    • 0022592172 scopus 로고
    • Rapid NMR imaging of dynamic processes using the FLASH technique
    • J. Frahm, A. Haase, D. Matthaei, " Rapid NMR imaging of dynamic processes using the FLASH technique" Magn Reson Med, vol. 3, no. 2, pp. 321-327, 1986. (Pubitemid 16112953)
    • (1986) Magnetic Resonance in Medicine , vol.3 , Issue.2 , pp. 321-327
    • Frahm, J.1    Haase, A.2    Matthaei, D.3
  • 2
    • 0021213449 scopus 로고
    • Multiple-slice NMR imaging by three-dimensional Fourier zeugmatography
    • J. H. den Boef, C. M. van Uijen, and C. D. Holzscherer, "Multiple-slice NMR imaging by three-dimensional fourier zeugmatography," Phys Med Biol, vol. 29, no. 7, pp. 857-867, 1984. (Pubitemid 14053951)
    • (1984) Physics in Medicine and Biology , vol.29 , Issue.7 , pp. 857-867
    • Den Boef, J.H.1    Van Uijen, C.M.J.2    Holzscherer, C.D.3
  • 3
    • 0026316572 scopus 로고
    • Coronary arteries: Breath-Hold MR angiography
    • R. R. Edelman, W. J. Manning, D. Burstein, and S. Paulin, "Coronary arteries: Breath-Hold MR angiography," Radiol, vol. 181, no. 3, pp. 641-643, 1991.
    • (1991) Radiol , vol.181 , Issue.3 , pp. 641-643
    • Edelman, R.R.1    Manning, W.J.2    Burstein, D.3    Paulin, S.4
  • 5
    • 0028351567 scopus 로고
    • Gadolinium-enhanced MR aortography
    • M. R. Prince, "Gadolinium-enhanced MR aortography," Radiol, vol. 191, no. 1, pp. 155-164, 1994. (Pubitemid 24098222)
    • (1994) Radiology , vol.191 , Issue.1 , pp. 155-164
    • Prince, M.R.1
  • 6
    • 0025336246 scopus 로고
    • Oxygenation-sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
    • DOI 10.1002/mrm.1910140108
    • S. Ogawa, T. M. Lee, A. S. Nayak, and P. Glynn, "Oxygenation-sensi- tive contrast in magnetic resonance image of rodent brain at high magnetic fields," Magn Reson Med, vol. 14, no. 1, pp. 68-78, Apr. 1990. (Pubitemid 20243866)
    • (1990) Magnetic Resonance in Medicine , vol.14 , Issue.1 , pp. 68-78
    • Ogawa, S.1    Lee, T.-M.2    Nayak, A.S.3    Glynn, P.4
  • 9
    • 0025165540 scopus 로고
    • Magnetization-prepared rapid gradient echo (MP-RAGE) magnetic resonance imaging of Morgagni's hernia
    • DOI 10.1016/0720-048X(90)90055-G
    • E. E. de Lange, S. R. Urbanski, J. P. Mugler, and J. R. Brookeman, "Magnetization-prepared rapid gradient echo (MP-RAGE) magnetic resonance imaging of morgagni's hernia," Eur J Radiol, vol. 11, no. 3, pp. 196-199, 1990. (Pubitemid 20348942)
    • (1990) European Journal of Radiology , vol.11 , Issue.3 , pp. 196-199
    • De Lange, E.E.1    Urbanski, S.R.2    Mugler III, J.P.3    Brookeman, J.R.4
  • 10
    • 0025034429 scopus 로고
    • Three-dimensional magnetization-prepared rapid gradient-echo imaging (3D MP RAGE)
    • DOI 10.1002/mrm.1910150117
    • J. P. Mugler and J. R. Brookeman, "Three-dimensional magnetization-prepared rapid gradient-echo imaging (3-D MP RAGE)," Magn Reson Med, vol. 15, no. 1, pp. 152-157, 1990. (Pubitemid 20284023)
    • (1990) Magnetic Resonance in Medicine , vol.15 , Issue.1 , pp. 152-157
    • Mugler III, J.P.1    Brookeman, J.R.2
  • 12
    • 33744530417 scopus 로고    scopus 로고
    • Encoding and reconstruction in parallel MRI
    • DOI 10.1002/nbm.1042
    • K. P. Pruessmann, "Encoding and reconstruction in parallel MRI," NMR Biomed, vol. 19, no. 3, pp. 288-299, 2006. (Pubitemid 43811103)
    • (2006) NMR in Biomedicine , vol.19 , Issue.3 , pp. 288-299
    • Pruessmann, K.P.1
  • 13
    • 0025610399 scopus 로고
    • The importance of phase-encoding order in ultra-short TR snapshot MR imaging
    • A. E. Holsinger and S. J. Riederer, "The importance of phase-encoding order in ultra-short TR snapshot MR imaging," Magn Reson Med, vol. 16, no. 3, pp. 481-488, 1990.
    • (1990) Magn Reson Med , vol.16 , Issue.3 , pp. 481-488
    • Holsinger, A.E.1    Riederer, S.J.2
  • 14
    • 0026860861 scopus 로고
    • Centric phase-encoding order in three-dimensional MP-RAGE sequences: Application to abdominal imaging
    • A. E. Bampton, S. J. Riederer, and H. W. Korin, "Centric phase-encoding order in three-dimensional MP-RAGE sequences: Application to abdominal imaging," J Magn Reson Imaging, vol. 2, no. 3, pp. 327-334, 1992.
    • (1992) J Magn Reson Imaging , vol.2 , Issue.3 , pp. 327-334
    • Bampton, A.E.1    Riederer, S.J.2    Korin, H.W.3
  • 15
    • 0030705199 scopus 로고    scopus 로고
    • Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath-hold three-dimensional gradient echo imaging
    • DOI 10.1002/mrm.1910380516
    • A. H. Wilman and S. J. Riederer, "Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath-hold three-dimensional gradient echo imaging," Magn Reson Med, vol. 38, pp. 793-802, 1997. (Pubitemid 27467719)
    • (1997) Magnetic Resonance in Medicine , vol.38 , Issue.5 , pp. 793-802
    • Wilman, A.H.1    Riederer, S.J.2
  • 16
    • 0036201635 scopus 로고    scopus 로고
    • 3He MRI: Spatial resolution and signal-to-noise ratio considerations
    • DOI 10.1002/mrm.10134
    • J. M. Wild, M. N. J. Paley, M. Viallon, W. G. Schreiber, E. J. R. van Beek, and P. D. Griffiths, "K-space filtering in 2D gradient-echo breath-hold hyperpolarized MRI: Spatial resolution and signal-to-noise ratio considerations," Magn Reson Med, vol. 47, no. 4, pp. 687-695, 2002. (Pubitemid 34263781)
    • (2002) Magnetic Resonance in Medicine , vol.47 , Issue.4 , pp. 687-695
    • Wild, J.M.1    Paley, M.N.J.2    Viallon, M.3    Schreiber, W.G.4    Van Beek, E.J.R.5    Griffiths, P.D.6
  • 17
    • 0027092710 scopus 로고
    • Shaping the signal response during the approach to steady state in three-dimensional magnetization-prepared rapid gradient-echo imaging using variable flip angles
    • DOI 10.1002/mrm.1910280202
    • J. P. Mugler, F. H. Epstein, and J. R. Brookeman, "Shaping the signal response during the approach to steady state in three-dimensional magnetization-prepared rapid gradient-echo imaging using variable flip angles," Magn Reson Med, vol. 28, no. 2, pp. 165-185, 1992. (Pubitemid 23027660)
    • (1992) Magnetic Resonance in Medicine , vol.28 , Issue.2 , pp. 165-185
    • Mugler III, J.P.1    Epstein, F.H.2    Brookeman, J.R.3
  • 18
    • 44049111982 scopus 로고
    • Nonlinear total variation based noise removal algorithms
    • L. I. Rudin, S. Osher, and E. Fatemi, "Nonlinear total variation based noise removal algorithms," Physica D, vol. 60, pp. 259-268, 1992.
    • (1992) Physica D , vol.60 , pp. 259-268
    • Rudin, L.I.1    Osher, S.2    Fatemi, E.3
  • 19
    • 34250320137 scopus 로고    scopus 로고
    • Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint
    • DOI 10.1002/mrm.21236
    • K. T. Block, M. Uecker, and J. Frahm, "Undersampled radial MRI with multiple coils: Iterative image reconstruction using a total variation constraint," Magn Reson Med, vol. 57, pp. 1086-1098, 2007. (Pubitemid 46911293)
    • (2007) Magnetic Resonance in Medicine , vol.57 , Issue.6 , pp. 1086-1098
    • Block, K.T.1    Uecker, M.2    Frahm, J.3
  • 20
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • DOI 10.1002/mrm.21391
    • M. Lustig, D. Donoho, and J. M. Pauly, "Sparse MRI: The application of compressed sensing for rapid MR imaging," Magn Reson Med, vol. 58, no. 6, pp. 1182-1195, Dec. 2007. (Pubitemid 350234205)
    • (2007) Magnetic Resonance in Medicine , vol.58 , Issue.6 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 21
    • 0026057828 scopus 로고
    • Flow-independent magnetic resonance projection angiography
    • Jan.
    • G. A. Wright, D. G. Nishimura, and A. Macovski, "Flow-independent magnetic resonance projection angiography," Magn Reson Med, vol. 17no. 1, pp. 126-140, Jan. 1991.
    • (1991) Magn Reson Med , vol.17 , Issue.1 , pp. 126-140
    • Wright, G.A.1    Nishimura, D.G.2    MacOvski, A.3
  • 24
    • 66149109239 scopus 로고    scopus 로고
    • Improving non-contrast-enhanced steady-state free precession angiography with compressed sensing
    • T. Çukur, M. Lustig, and D. G. Nishimura, "Improving non-contrast-enhanced steady-state free precession angiography with compressed sensing," Magn Reson Med, vol. 61, no. 5, pp. 1122-1131, 2009.
    • (2009) Magn Reson Med , vol.61 , Issue.5 , pp. 1122-1131
    • Çukur, T.1    Lustig, M.2    Nishimura, D.G.3
  • 26
    • 67049136377 scopus 로고    scopus 로고
    • Non-contrast-enhanced flow-independent peripheral MR angiography with balanced SSFP
    • T. Çukur, J. H. Lee, N. K. Bangerter, B. A. Hargreaves, and D. G. Nishimura, "Non-contrast-enhanced flow-independent peripheral MR angiography with balanced SSFP," Magn Reson Med, vol. 61, no. 6, pp. 1533-1539, 2009.
    • (2009) Magn Reson Med , vol.61 , Issue.6 , pp. 1533-1539
    • Çukur, T.1    Lee, J.H.2    Bangerter, N.K.3    Hargreaves, B.A.4    Nishimura, D.G.5
  • 27
    • 33644791275 scopus 로고    scopus 로고
    • Alternating repetition time balanced steady state free precession
    • DOI 10.1002/mrm.20790
    • J. Leupold, J. Hennig, and K. Scheffler, "Alternating repetition time balanced steady state free precession," Magn Reson Med, vol. 55, pp. 557-565, 2006. (Pubitemid 43352554)
    • (2006) Magnetic Resonance in Medicine , vol.55 , Issue.3 , pp. 557-565
    • Leupold, J.1    Hennig, J.2    Scheffler, K.3
  • 28
    • 67049165186 scopus 로고    scopus 로고
    • Spectrally selective -insensitive magnetization preparation sequence
    • R. Nezafat, R. Ouwerkerk, A. J. Derbyshire, M. Stuber, and E. R. McVeigh, "Spectrally selective -insensitive magnetization preparation sequence," Magn Reson Med, vol. 61, no. 6, pp. 1326-1335, 2009.
    • (2009) Magn Reson Med , vol.61 , Issue.6 , pp. 1326-1335
    • Nezafat, R.1    Ouwerkerk, R.2    Derbyshire, A.J.3    Stuber, M.4    McVeigh, E.R.5
  • 29
    • 0026953545 scopus 로고
    • Altered phase encoding order for reduced sensitivity to motion corruption in 3DFT MR imaging
    • H. W. Korin, S. J. Riederer, A. E. H. Bampton, and R. L. Ehman, "Altered phase encoding order for reduced sensitivity to motion corruption in 3DFT MR imaging," J Magn Reson Imaging, vol. 2, no. 1, pp. 687-693, 1992.
    • (1992) J Magn Reson Imaging , vol.2 , Issue.1 , pp. 687-693
    • Korin, H.W.1    Riederer, S.J.2    Bampton, A.E.H.3    Ehman, R.L.4
  • 30
    • 0034956696 scopus 로고    scopus 로고
    • Characterization and reduction of the transient response in steady-state MR imaging
    • DOI 10.1002/mrm.1170
    • B. A. Hargreaves, S. S. Vasanawala, J. M. Pauly, and D. G. Nishimura, "Characterization and reduction of the transient response in steady-state MR imaging," Magn Reson Med, vol. 46, no. 1, pp. 149-158, Jul. 2001. (Pubitemid 32592148)
    • (2001) Magnetic Resonance in Medicine , vol.46 , Issue.1 , pp. 149-158
    • Hargreaves, B.A.1    Vasanawala, S.S.2    Pauly, J.M.3    Nishimura, D.G.4
  • 31
    • 0042494544 scopus 로고    scopus 로고
    • Simplified model and stabilization of SSFP sequences
    • P. L. Roux, "Simplified model and stabilization of SSFP sequences," J Magn Reson, vol. 163, no. 1, pp. 23-37, 2003.
    • (2003) J Magn Reson , vol.163 , Issue.1 , pp. 23-37
    • Roux, P.L.1
  • 32
    • 0037382249 scopus 로고    scopus 로고
    • On the transient phase of balanced SSFP sequences
    • DOI 10.1002/mrm.10421
    • K. Scheffler, "On the transient phase of balanced SSFP sequences," Magn Reson Med, vol. 49, no. 4, pp. 781-783, Apr. 2003. (Pubitemid 36389991)
    • (2003) Magnetic Resonance in Medicine , vol.49 , Issue.4 , pp. 781-783
    • Scheffler, K.1
  • 33
    • 0038050726 scopus 로고    scopus 로고
    • Double inversion black-blood fast spin-echo imaging of the human heart: A comparison between 1.5T and 3.0T
    • DOI 10.1002/jmri.10316
    • R. L. Greenman, J. E. Shirosky, R. V. Mulkern, and N. M. Rofsky, "Double inversion black-blood fast spin-echo imaging of the human heart: A comparison between 1.5T and 3.0T," J Magn Reson Imaging, vol. 17, pp. 648-655, 2003. (Pubitemid 36665868)
    • (2003) Journal of Magnetic Resonance Imaging , vol.17 , Issue.6 , pp. 648-655
    • Greenman, R.L.1    Shirosky, J.E.2    Mulkern, R.V.3    Rofsky, N.M.4
  • 34
    • 0033594967 scopus 로고    scopus 로고
    • Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA
    • R. M. Botnar, M. Stuber, P. G. Danias, K. V. Kissinger, and W. J. Manning, "Improved coronary artery definition with -weighted, free-breathing, three-dimensional coronary MRA," Circ, vol. 99, no. 24, pp. 3139-3148, 1999. (Pubitemid 29289079)
    • (1999) Circulation , vol.99 , Issue.24 , pp. 3139-3148
    • Botnar, R.M.1    Stuber, M.2    Danias, P.G.3    Kissinger, K.V.4    Manning, W.J.5
  • 36
    • 33645653318 scopus 로고    scopus 로고
    • A review of image denoising algorithms, with a new one
    • DOI 10.1137/040616024
    • A. Buades, B. Coll, and J. M. Morel, "A review of image denosing methods, with a new one," Multiscale Model. Simul., vol. 4, no. 2, pp. 490-530, 2005. (Pubitemid 43890582)
    • (2005) Multiscale Modeling and Simulation , vol.4 , Issue.2 , pp. 490-530
    • Buades, A.1    Coll, B.2    Morel, J.M.3
  • 37
    • 0020665490 scopus 로고
    • Noninvasive determination of elastic properties and diameter of human limb arteries
    • B. I. Mazhbich, "Noninvasive determination of elastic properties and diameter of human limb arteries," Pflugers Arch, vol. 396, no. 3, pp. 254-259, 1983. (Pubitemid 13144109)
    • (1983) Pflugers Archiv European Journal of Physiology , vol.396 , Issue.3 , pp. 254-259
    • Mazhbich, B.I.1
  • 39
    • 0034120692 scopus 로고    scopus 로고
    • Reconstructing MR images from undersampled data: Data-weighing considerations
    • DOI 10.1002/1522-2594(200006)43:6<867::AID-MRM13>3.0.CO;2-2
    • J. G. Pipe, "Reconstructing MR images from undersampled data: Data-Weighting considerations," Magn Reson Med, vol. 43, pp. 867-875, 2000. (Pubitemid 30387608)
    • (2000) Magnetic Resonance in Medicine , vol.43 , Issue.6 , pp. 867-875
    • Pipe, J.G.1
  • 41
    • 33750633047 scopus 로고    scopus 로고
    • On the origin of apparent low tissue signals in balanced SSFP
    • DOI 10.1002/mrm.21056
    • O. Bieri and K. Scheffler, "On the origin of apparent low tissue signals in balanced SSFP," Magn Reson Med, vol. 56, pp. 1067-1074, 2006. (Pubitemid 44691349)
    • (2006) Magnetic Resonance in Medicine , vol.56 , Issue.5 , pp. 1067-1074
    • Bieri, O.1    Scheffler, K.2
  • 43
    • 38949084543 scopus 로고    scopus 로고
    • 1ρ mapping in cartilage using 3D magnetization-prepared angle-modulated partitioned k-space spoiled gradient echo snapshots (3D MAPSS)
    • DOI 10.1002/mrm.21414
    • X. Li, E. T. Han, R. F. Busse, and S. Majumdar, "In vivo mapping in cartilage using 3-D magnetization-prepared angle-modulated partitioned k-space spoiled gradient echo snapshots (3-D MAPSS)," Magn Reson Med, vol. 59, no. 2, pp. 298-307, 2008. (Pubitemid 351220093)
    • (2008) Magnetic Resonance in Medicine , vol.59 , Issue.2 , pp. 298-307
    • Li, X.1    Han, E.T.2    Busse, R.F.3    Majumdar, S.4
  • 44
    • 0022121670 scopus 로고
    • Resolution and noise considerations in MRI systems with time-varying gradients
    • I. Shenberg and A. Macovski, "Resolution and noise considerations in MRI systems with time-varying gradients," IEEE Trans Med Imaging, vol. MI-4, no. 3, pp. 144-152, 1985. (Pubitemid 16524629)
    • (1985) IEEE Transactions on Medical Imaging , vol.MI-4 , Issue.3 , pp. 144-152
    • Shenberg Itzhak1    Macovski Albert2
  • 45
    • 0024472641 scopus 로고
    • 2 decay effects in echo planar imaging
    • K. Oshio and M. Singh, "A computer simulation of decay effects in echo planar imaging," Magn Reson Med, vol. 11, no. 3, pp. 389-397, 1989. (Pubitemid 19225575)
    • (1989) Magnetic Resonance in Medicine , vol.11 , Issue.3 , pp. 389-397
    • Oshio, K.1    Singh, M.2
  • 50
    • 0033621785 scopus 로고    scopus 로고
    • Imaging using magnetization-prepared projection encoding (MaPPE)
    • DOI 10.1002/(SICI)1522-2594(200003)43:3<421::AID-MRM14>3.0.CO;2-X
    • A. C. Nugent and G. A. Johnson, " imaging using magnetization- prepared projection encoding (mappe)," Magn Reson Med, vol. 43, no. 3, pp. 421-428, 2000. (Pubitemid 30127529)
    • (2000) Magnetic Resonance in Medicine , vol.43 , Issue.3 , pp. 421-428
    • Nugent, A.C.1    Johnson, G.A.2
  • 52
    • 79955629344 scopus 로고    scopus 로고
    • Designing variable flip angle refocusing trains to optimize resolution, signal-to-noise, and rf power
    • R. F. Busse, "Designing variable flip angle refocusing trains to optimize resolution, signal-to-noise, and rf power," in Proc. 13th Annu. Meeting ISMRM, Miami Beach, 2005, pp. 2349-12349.
    • (2005) Proc. 13th Annu. Meeting ISMRM, Miami Beach , pp. 2349-12349
    • Busse, R.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.