메뉴 건너뛰기




Volumn 105, Issue 5, 2011, Pages 282-285

The use of a coded healing abutment as an impression coping to design and mill an individualized anatomic abutment: A clinical report

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CASE REPORT; DENTURE; FEMALE; HUMAN; HYPODONTIA; MANDIBLE RECONSTRUCTION; METHODOLOGY; MULTIMODALITY CANCER THERAPY; ORTHODONTICS; ORTHOGNATHIC SURGERY; PATIENT CARE PLANNING; RETROGNATHIA; TOOTH CROWN; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TREATMENT OUTCOME;

EID: 79955609704     PISSN: 00223913     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0022-3913(11)00056-4     Document Type: Article
Times cited : (20)

References (9)
  • 1
    • 52249091557 scopus 로고    scopus 로고
    • The accuracy of implant impressions: A systematic review
    • Lee H, So JS, Hochstedler JL, Ercoli C. The accuracy of implant impressions: a systematic review. J Prosthet Dent 2008;100:285-91.
    • (2008) J Prosthet Dent , vol.100 , pp. 285-291
    • Lee, H.1    So, J.S.2    Hochstedler, J.L.3    Ercoli, C.4
  • 2
    • 50849091256 scopus 로고    scopus 로고
    • Implant cast accuracy as a function of impression techniques and impression material viscosity
    • Walker MP, Ries D, Borello B. Implant cast accuracy as a function of impression techniques and impression material viscosity. Int J Oral maxillofac Implants 2008;23:669-74.
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 669-674
    • Walker, M.P.1    Ries, D.2    Borello, B.3
  • 3
    • 65649123098 scopus 로고    scopus 로고
    • The press-fit implant impression coping technique
    • Nissan J. Ghelfan O. The press-fit implant impression coping technique. J Prosthet Dent 2009;101:413-4.
    • (2009) J Prosthet Dent , vol.101 , pp. 413-414
    • Nissan, J.1    Ghelfan, O.2
  • 4
    • 60449107531 scopus 로고    scopus 로고
    • Making an implant-level impression using solid plastic-press-fit, closed-tray impression copings: A clinical report
    • Selecman AM, Wicks RA. Making an implant-level impression using solid plastic-press-fit, closed-tray impression copings: a clinical report. J Prosthet Dent 2009;101:158-9.
    • (2009) J Prosthet Dent , vol.101 , pp. 158-159
    • Selecman, A.M.1    Wicks, R.A.2
  • 5
    • 23944480831 scopus 로고    scopus 로고
    • Virtual-designed and computer-milled implant abutments
    • DOI 10.1016/j.joms.2005.05.158, PII S027823910500738X
    • Priest G. Virtual-designed and computer-milled implant abutments. J Oral Maxillofac Surg 2005;63:22-32. (Pubitemid 41205520)
    • (2005) Journal of Oral and Maxillofacial Surgery , vol.63 , Issue.9 SUPPL. , pp. 22-32
    • Priest, G.1
  • 6
    • 33644881396 scopus 로고    scopus 로고
    • A novel technique using a coded healing abutment for the fabrication of a CAD/CAM titanium abutment for an implant-supported restoration
    • DOI 10.1016/j.prosdent.2005.12.013, PII S0022391305006967
    • Grossmann Y, Pasciuta M, Finger IM. A novel technique using a coded healing abutment for the fabrication of a CAD/ CAM titanium abutment for an implant-supported restoration. J Prosthet Dent 2006;95:258-61. (Pubitemid 43388119)
    • (2006) Journal of Prosthetic Dentistry , vol.95 , Issue.3 , pp. 258-261
    • Grossmann, Y.1    Pasciuta, M.2    Finger, I.M.3
  • 7
    • 33745763436 scopus 로고    scopus 로고
    • Two new clinical/laboratory protocols for CAD/CAM implant restorations
    • Drago CJ. Two new clinical/laboratory protocols for CAD/CAM implant restorations. J Am Dent Assoc 2006;137:794-800. (Pubitemid 44013457)
    • (2006) Journal of the American Dental Association , vol.137 , Issue.6 , pp. 794-800
    • Drago, C.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.