메뉴 건너뛰기




Volumn 5, Issue 2, 2011, Pages 263-270

Simultaneous closed-loop automatic tuning method for cascade controllers

Author keywords

[No Author keywords available]

Indexed keywords

AUTOMATIC TUNING; CASCADE CONTROLLER; CLOSED-LOOP; ESTIMATED MODEL; INTERNAL MODEL CONTROL; PERFORMANCE ASSESSMENT; PROPORTIONAL INTEGRAL DERIVATIVE CONTROLLERS; SECONDARY PROCESS; SELF-REGULATING PROCESS; SET-POINT; SIMULATION RESULT;

EID: 79955542839     PISSN: 17518644     EISSN: 17518652     Source Type: Journal    
DOI: 10.1049/iet-cta.2010.0082     Document Type: Article
Times cited : (47)

References (24)
  • 4
    • 0034921921 scopus 로고    scopus 로고
    • Improving performance using cascade control and a Smith predictor
    • DOI 10.1016/S0019-0578(00)00054-9, PII S0019057800000549
    • Kaya, I.: ' Improving performance using cascade control and a Smith predictor ', ISA Trans., 2001, 40, p. 223-234 10.1016/S0019-0578(00)00054-9 (Pubitemid 32684535)
    • (2001) ISA Transactions , vol.40 , Issue.3 , pp. 223-234
    • Kaya, I.1
  • 5
    • 7544236269 scopus 로고    scopus 로고
    • Decoupling two-degree-of-freedom control strategy for cascade control systems
    • 10.1016/j.jprocont.2004.06.001 0959-1524
    • Liu, T., Gu, D., and Zhang, W.: ' Decoupling two-degree-of-freedom control strategy for cascade control systems ', J. Process Control, 2007, 15, p. 159-167 10.1016/j.jprocont.2004.06.001 0959-1524
    • (2007) J. Process Control , vol.15 , pp. 159-167
    • Liu, T.1    Gu, D.2    Zhang, W.3
  • 6
    • 33845229636 scopus 로고    scopus 로고
    • Improved cascade control structure for enhanced performance
    • DOI 10.1016/j.jprocont.2006.08.008, PII S0959152406001004
    • Kaya, I., Tan, N., and Atherton, D.P.: ' Improved cascade control structure for enhanced performance ', J. Process Control, 2007, 17, p. 3-16 10.1016/j.jprocont.2006.08.008 0959-1524 (Pubitemid 44854492)
    • (2007) Journal of Process Control , vol.17 , Issue.1 , pp. 3-16
    • Kaya, I.1    Tan, N.2    Atherton, D.P.3
  • 7
    • 0028391689 scopus 로고
    • Relay feedback auto-tuning of cascade controllers
    • 10.1109/87.273109 1063-6536
    • Hang, C.C., Loh, A.P., and Vasnani, V.U.: ' Relay feedback auto-tuning of cascade controllers ', IEEE Trans. Control Syst. Technol., 1994, 2, p. 42-45 10.1109/87.273109 1063-6536
    • (1994) IEEE Trans. Control Syst. Technol. , vol.2 , pp. 42-45
    • Hang, C.C.1    Loh, A.P.2    Vasnani, V.U.3
  • 9
    • 9744235160 scopus 로고    scopus 로고
    • Cascade controller tuning by relay auto tune method
    • 0019-4964
    • Vivek, S., and Chidambaram, M.: ' Cascade controller tuning by relay auto tune method ', J. Indian Inst. Sci., 2004, 84, p. 89-97 0019-4964
    • (2004) J. Indian Inst. Sci. , vol.84 , pp. 89-97
    • Vivek, S.1    Chidambaram, M.2
  • 11
    • 0012630756 scopus 로고    scopus 로고
    • Simultaneous online automatic tuning of cascade control for open loop stable processes
    • 10.1016/S0019-0578(00)00006-9
    • Tan, K.K., Lee, T.H., and Ferdous, R.: ' Simultaneous online automatic tuning of cascade control for open loop stable processes ', ISA Trans., 2000, 39, p. 233-242 10.1016/S0019-0578(00)00006-9
    • (2000) ISA Trans. , vol.39 , pp. 233-242
    • Tan, K.K.1    Lee, T.H.2    Ferdous, R.3
  • 12
    • 64849116008 scopus 로고    scopus 로고
    • Autotuning in cascaded systems based on a single relay experiment
    • 10.1016/j.jprocont.2008.11.013 0959-1524
    • Leva, A., and Donida, F.: ' Autotuning in cascaded systems based on a single relay experiment ', J. Process Control, 2009, 19, p. 896-905 10.1016/j.jprocont.2008.11.013 0959-1524
    • (2009) J. Process Control , vol.19 , pp. 896-905
    • Leva, A.1    Donida, F.2
  • 13
    • 77952890076 scopus 로고    scopus 로고
    • An automatic tuning method for cascade control systems
    • Munich, Germany
    • Visioli, A., and Piazzi, A.: ' An automatic tuning method for cascade control systems ', Proc. IEEE Int. Conf. on Control Applications, Munich, Germany, 2006, p. 2968-2973
    • (2006) Proc. IEEE Int. Conf. on Control Applications , pp. 2968-2973
    • Visioli, A.1    Piazzi, A.2
  • 14
    • 0032074639 scopus 로고    scopus 로고
    • PID controller tuning to obtain desired closed loop responses for cascade control systems
    • Lee, Y., Park, S., and Lee, M.: ' PID controller tuning to obtain desired closed loop responses for cascade control systems ', Ind. Eng. Chem. Res., 1998, 37, p. 1859-1865 10.1021/ie970769t 0888-5885 (Pubitemid 128718059)
    • (1998) Industrial and Engineering Chemistry Research , vol.37 , Issue.5 , pp. 1859-1865
    • Lee, Y.1    Park, S.2    Lee, M.3
  • 15
    • 0037193639 scopus 로고    scopus 로고
    • Enhanced control with a general cascade control structure
    • Lee, Y., Oh, S., and Park, S.: ' Enhanced control with a general cascade control structure ', Ind. Eng. Chem. Res., 2002, 41, p. 2679-2688 10.1021/ie010157f 0888-5885 (Pubitemid 34575349)
    • (2002) Industrial and Engineering Chemistry Research , vol.41 , Issue.11 , pp. 2679-2688
    • Lee, Y.1    Oh, S.2    Park, S.3
  • 20
    • 0027649522 scopus 로고
    • Automatic tuning and adaptation for PID controllers - A survey
    • 10.1016/0967-0661(93)91394-C 0967-0661
    • Åström, K.J., Hägglund, T., Hang, C.C., and Ho, W.K.: ' Automatic tuning and adaptation for PID controllers - a survey ', Control Eng. Pract., 1993, 1, p. 699-714 10.1016/0967-0661(93)91394-C 0967-0661
    • (1993) Control Eng. Pract. , vol.1 , pp. 699-714
    • Åström, K.J.1    Hägglund, T.2    Hang, C.C.3    Ho, W.K.4
  • 21
    • 65349090784 scopus 로고    scopus 로고
    • Performance assessment and retuning of PID controllers
    • 10.1021/ie800812b 0888-5885
    • Veronesi, M., and Visioli, A.: ' Performance assessment and retuning of PID controllers ', Ind. Eng. Chem. Res., 2009, 48, p. 2616-2623 10.1021/ie800812b 0888-5885
    • (2009) Ind. Eng. Chem. Res. , vol.48 , pp. 2616-2623
    • Veronesi, M.1    Visioli, A.2
  • 22
    • 0037408952 scopus 로고    scopus 로고
    • Simple analytic rules for model reduction and PID controller tuning
    • 10.1016/S0959-1524(02)00062-8 0959-1524
    • Skogestad, S.: ' Simple analytic rules for model reduction and PID controller tuning ', J. Process Control, 2003, 13, p. 291-309 10.1016/S0959-1524(02)00062-8 0959-1524
    • (2003) J. Process Control , vol.13 , pp. 291-309
    • Skogestad, S.1
  • 23
    • 30744453969 scopus 로고    scopus 로고
    • An overview of control performance assessment technology and industrial applications
    • DOI 10.1016/j.conengprac.2005.11.005, PII S0967066105002479, Intelligent Control Systems and Signal Processing ICONS 2003
    • Jelali, M.: ' An overview of control performance assessment technology and industrial applications ', Control Eng. Pract., 2006, 14, p. 441-466 10.1016/j.conengprac.2005.11.005 0967-0661 (Pubitemid 43092173)
    • (2006) Control Engineering Practice , vol.14 , Issue.5 , pp. 441-466
    • Jelali, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.