메뉴 건너뛰기




Volumn 7899, Issue , 2011, Pages

Photoacoustic imaging of brachytherapy seeds using a channel-domain ultrasound array system

Author keywords

Brachytherapy; Photoacoustic imaging; Ultrasound flash imaging

Indexed keywords

1064 NM; ARRAY TRANSDUCERS; BRACHYTHERAPY; CHICKEN TISSUE; COREGISTERED; FLUENCES; HUMAN SKIN; IMAGING MODALITY; MULTI CORE; NEEDLE GUIDANCE; OPTICAL WAVELENGTH; PARALLEL CHANNEL; PCI EXPRESS; PENETRATION DEPTH; PHOTO-ACOUSTIC IMAGING; PHOTOACOUSTIC IMAGE; PHOTOACOUSTIC SYSTEMS; PROSTATE CANCERS; PULSE SEQUENCE; RADIATION THERAPY; REAL TIME; SIGNAL TO NOISE; TREATMENT DURATION; TUMOR LOCATION; ULTRASOUND ARRAYS; ULTRASOUND FLASH IMAGING;

EID: 79955520544     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.875550     Document Type: Conference Paper
Times cited : (1)

References (9)
  • 1
    • 0034333143 scopus 로고    scopus 로고
    • Optimizing target coverage by dosimetric feedback during prostate brachytherapy
    • (Nov.)
    • Cormack, R., "Optimizing target coverage by dosimetric feedback during prostate brachytherapy, " International Journal of Radiation Oncology*Biology*Physics 48, 1245-1249 (Nov. 2000).
    • (2000) International Journal of Radiation Oncology*Biology*Physics , vol.48 , pp. 1245-1249
    • Cormack, R.1
  • 2
    • 25144525491 scopus 로고    scopus 로고
    • CT-ultrasound fusion prostate brachytherapy: A dynamic dosimetry feedback and improvement method. A report of 54 consecutive cases
    • DOI 10.1016/j.brachy.2005.07.005, PII S1538472105001108
    • Fuller, D. B., Jin, H., Koziol, J. A., and Feng, A. C., "CT-ultrasound fusion prostate brachytherapy: A dynamic dosimetry feedback and improvement method. A report of 54 consecutive cases, " Brachytherapy 4(3), 207-216 (2005). (Pubitemid 41338054)
    • (2005) Brachytherapy , vol.4 , Issue.3 , pp. 207-216
    • Fuller, D.B.1    Jin, H.2    Koziol, J.A.3    Feng, A.C.4
  • 3
    • 0038693595 scopus 로고    scopus 로고
    • Intraoperative dynamic dosimetry for prostate implants
    • DOI 10.1088/0031-9155/48/9/306, PII S003191550356657X
    • Todor, D. A., Zaider, M., Cohen, G. N., Worman, M. F., and Zelefsky, M. J., "Intraoperative dynamic dosimetry for prostate implants, " Physics in Medicine and Biology 48, 1153-1171 (May 2003). (Pubitemid 36644116)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.9 , pp. 1153-1171
    • Todor, D.A.1    Zaider, M.2    Cohen, G.N.3    Worman, M.F.4    Zelefsky, M.J.5
  • 5
    • 79951628480 scopus 로고    scopus 로고
    • Deeply penetrating in vivo photoacoustic imaging using a clinical ultrasound array system
    • (July)
    • Kim, C., Erpelding, T. N., Jankovic, L., Pashley, M. D., and Wang, L. V., "Deeply penetrating in vivo photoacoustic imaging using a clinical ultrasound array system, " Biomedical Optics Express 1, 278-284 (July 2010).
    • (2010) Biomedical Optics Express , vol.1 , pp. 278-284
    • Kim, C.1    Erpelding, T.N.2    Jankovic, L.3    Pashley, M.D.4    Wang, L.V.5
  • 8
    • 3943068419 scopus 로고    scopus 로고
    • Photoacoustic and ultrasonic coimage with a linear transducer array
    • Zeng, Y., Xing, D., Wang, Y., Yin, B., and Chen, Q., "Photoacoustic and ultrasonic coimage with a linear transducer array, " Optics Letters 29(15), 1760-1762 (2004).
    • (2004) Optics Letters , vol.29 , Issue.15 , pp. 1760-1762
    • Zeng, Y.1    Xing, D.2    Wang, Y.3    Yin, B.4    Chen, Q.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.