메뉴 건너뛰기




Volumn 7899, Issue , 2011, Pages

A miniature all-optical photoacoustic imaging probe

Author keywords

Endoscopic imaging; Fabry perot sensor; Hydrophone; Intravascular imaging; Oct; Photoacoustics; Ultrasound

Indexed keywords

ENDOSCOPIC IMAGING; FABRY PEROT SENSOR; INTRAVASCULAR IMAGING; OCT; PHOTOACOUSTICS; ULTRASOUND;

EID: 79955512802     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.874883     Document Type: Conference Paper
Times cited : (112)

References (4)
  • 1
    • 0000973144 scopus 로고    scopus 로고
    • An optical fibre photoacoustic-photothermal probe
    • Beard, P. C., Perennes, F., Draguioti, E., and Mills, T. N., "An optical fibre photoacoustic-photothermal probe, " Optics Letters 23(15), 1235-1237 (1998).
    • (1998) Optics Letters , vol.23 , Issue.15 , pp. 1235-1237
    • Beard, P.C.1    Perennes, F.2    Draguioti, E.3    Mills, T.N.4
  • 2
    • 67649126703 scopus 로고    scopus 로고
    • A Fabry-Pérot fiber-optic ultrasonic hydrophone for the simultaneous measurement of temperature and acoustic pressure
    • Morris, P. M., Hurrell, A., Shaw, A., Zhang, E., Beard, P. C., "A Fabry-Pérot fiber-optic ultrasonic hydrophone for the simultaneous measurement of temperature and acoustic pressure, " Journal of the Acoustical Society of America, 125(6), 3611-3622 (2009).
    • (2009) Journal of the Acoustical Society of America , vol.125 , Issue.6 , pp. 3611-3622
    • Morris, P.M.1    Hurrell, A.2    Shaw, A.3    Zhang, E.4    Beard, P.C.5
  • 3
    • 41449089257 scopus 로고    scopus 로고
    • Backward-mode multiwavelength photoacoustic scanner using a planar Fabry-Perot polymer film ultrasound sensor for high-resolution three-dimensional imaging of biological tissues
    • DOI 10.1364/AO.47.000561
    • Zhang, E., Laufer, J., Beard, P., "Backward-mode multiwavelength photoacoustic scanner using a planar Fabry-Perot polymer film ultrasound sensor for high-resolution three-dimensional imaging of biological tissues, " Applied Optics 47, 561-577 (2008). (Pubitemid 351456537)
    • (2008) Applied Optics , vol.47 , Issue.4 , pp. 561-577
    • Zhang, E.1    Laufer, J.2    Beard, P.3
  • 4
    • 63649150845 scopus 로고    scopus 로고
    • In vivo high-resolution 3D photoacoustic imaging of superficial vascular anatomy
    • Zhang, E. Z., Laufer, J. G., Pedley, R. B., Beard, P. C., "In vivo high-resolution 3D photoacoustic imaging of superficial vascular anatomy, " Physics in Medicine and Biology, 54, 1035-1046 (2009).
    • (2009) Physics in Medicine and Biology , vol.54 , pp. 1035-1046
    • Zhang, E.Z.1    Laufer, J.G.2    Pedley, R.B.3    Beard, P.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.