메뉴 건너뛰기




Volumn 55, Issue 4, 2011, Pages 645-652

Recent advances in the application of transmission Raman spectroscopy to pharmaceutical analysis

Author keywords

Pharmaceutical formulations; Quality control; Quantitative analysis; Transmission Raman

Indexed keywords

HIGH PERFORMANCE LIQUID CHROMATOGRAPHY; KERNEL METHOD; PHARMACEUTICAL ENGINEERING; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; RAMAN SPECTROMETRY; REVIEW; SCANNING ELECTRON MICROSCOPY; TABLET;

EID: 79955463892     PISSN: 07317085     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jpba.2010.10.029     Document Type: Review
Times cited : (122)

References (43)
  • 2
    • 0036971669 scopus 로고    scopus 로고
    • Effect of powder properties on the intensity of Raman scattering by crystalline solids
    • Wang H., Mann C.K., Vickers T.J. Effect of powder properties on the intensity of Raman scattering by crystalline solids. Appl. Spectrosc. 2002, 56:1538-1544.
    • (2002) Appl. Spectrosc. , vol.56 , pp. 1538-1544
    • Wang, H.1    Mann, C.K.2    Vickers, T.J.3
  • 3
    • 23944455134 scopus 로고    scopus 로고
    • Characterization of different laser irradiation methods for quantitative Raman tablet assessment
    • Johansson J., Pettersson S., Folestad S. Characterization of different laser irradiation methods for quantitative Raman tablet assessment. J. Pharm. Biomed. Anal. 2005, 39:510-516.
    • (2005) J. Pharm. Biomed. Anal. , vol.39 , pp. 510-516
    • Johansson, J.1    Pettersson, S.2    Folestad, S.3
  • 7
    • 84975594841 scopus 로고
    • Three-dimensional imaging of objects embedded in turbid media with fluorescence and Raman spectroscopy
    • Wu J., Wang Y., Perelman L., Itzkan I., Dasari R., Feld M.S. Three-dimensional imaging of objects embedded in turbid media with fluorescence and Raman spectroscopy. Appl. Optics 1995, 34:3425-3430.
    • (1995) Appl. Optics , vol.34 , pp. 3425-3430
    • Wu, J.1    Wang, Y.2    Perelman, L.3    Itzkan, I.4    Dasari, R.5    Feld, M.S.6
  • 8
    • 14044252088 scopus 로고    scopus 로고
    • Depth profiling in diffusely scattering media using Raman spectroscopy and picosecond kerr gating
    • Matousek P., Everall N., Towrie M., Parker A.W. Depth profiling in diffusely scattering media using Raman spectroscopy and picosecond kerr gating. Appl. Spectrosc. 2005, 59:200-205.
    • (2005) Appl. Spectrosc. , vol.59 , pp. 200-205
    • Matousek, P.1    Everall, N.2    Towrie, M.3    Parker, A.W.4
  • 9
    • 0035697531 scopus 로고    scopus 로고
    • Picosecond time-resolved Raman spectroscopy of solids: capabilities and limitations for fluorescence rejection and the influence of diffuse reflectance
    • Everall N., Hahn T., Matousek P., Parker A.W., Towrie M. Picosecond time-resolved Raman spectroscopy of solids: capabilities and limitations for fluorescence rejection and the influence of diffuse reflectance. Appl. Spectrosc. 2001, 55:1701-1708.
    • (2001) Appl. Spectrosc. , vol.55 , pp. 1701-1708
    • Everall, N.1    Hahn, T.2    Matousek, P.3    Parker, A.W.4    Towrie, M.5
  • 11
    • 0033331556 scopus 로고    scopus 로고
    • Efficient rejection of fluorescence from Raman spectra using picosecond kerr gating
    • Matousek P., Towrie M., Stanley A., Parker A.W. Efficient rejection of fluorescence from Raman spectra using picosecond kerr gating. Appl. Spectrosc. 1999, 53:1485-1489.
    • (1999) Appl. Spectrosc. , vol.53 , pp. 1485-1489
    • Matousek, P.1    Towrie, M.2    Stanley, A.3    Parker, A.W.4
  • 12
    • 33644759204 scopus 로고    scopus 로고
    • Subsurface Raman spectroscopy and mapping using a globally illuminated non-confocal fiber-optic array probe in the presence of Raman photon migration
    • Schulmerich M.V., Finney W.F., Fredricks R.A., Morris M.D. Subsurface Raman spectroscopy and mapping using a globally illuminated non-confocal fiber-optic array probe in the presence of Raman photon migration. Appl. Spectrosc. 2006, 60:109-114.
    • (2006) Appl. Spectrosc. , vol.60 , pp. 109-114
    • Schulmerich, M.V.1    Finney, W.F.2    Fredricks, R.A.3    Morris, M.D.4
  • 13
    • 33845285405 scopus 로고    scopus 로고
    • Transcutaneous fiber optic Raman spectroscopy of bone using annular illumination and a circular array of collection fibers
    • Schulmerich M.V., Dooley K.A., Morris M.D., Vanasse T.M., Goldstein S.A. Transcutaneous fiber optic Raman spectroscopy of bone using annular illumination and a circular array of collection fibers. J. Biomed. Opt. 2006, 11:060502.
    • (2006) J. Biomed. Opt. , vol.11 , pp. 060502
    • Schulmerich, M.V.1    Dooley, K.A.2    Morris, M.D.3    Vanasse, T.M.4    Goldstein, S.A.5
  • 14
    • 34547278607 scopus 로고    scopus 로고
    • Deep non-invasive Raman spectroscopy of living tissue and powders
    • Matousek P. Deep non-invasive Raman spectroscopy of living tissue and powders. Chem. Soc. Rev. 2007, 36:1292-1304.
    • (2007) Chem. Soc. Rev. , vol.36 , pp. 1292-1304
    • Matousek, P.1
  • 15
    • 55549105179 scopus 로고    scopus 로고
    • Deep noninvasive Raman spectroscopy of turbid media
    • Macleod N.A., Matousek P. Deep noninvasive Raman spectroscopy of turbid media. Appl. Spectrosc. 2008, 62:291A-304A.
    • (2008) Appl. Spectrosc. , vol.62
    • Macleod, N.A.1    Matousek, P.2
  • 16
    • 67149115392 scopus 로고    scopus 로고
    • Emerging concepts in deep Raman spectroscopy of biological tissue
    • Matousek P., Stone N. Emerging concepts in deep Raman spectroscopy of biological tissue. Analyst 2009, 134:1058-1066.
    • (2009) Analyst , vol.134 , pp. 1058-1066
    • Matousek, P.1    Stone, N.2
  • 17
    • 0000837337 scopus 로고
    • Die Intensitat Des Ramanspektrums Polykristalliner Substanzen. I. Strahlungsbilanz Von Substanz Und Probenanordnung
    • Schrader B., Bergmann G. Die Intensitat Des Ramanspektrums Polykristalliner Substanzen. I. Strahlungsbilanz Von Substanz Und Probenanordnung. Zeitschrift fur Analytische Chemie Fresenius 1967, 225:230-247.
    • (1967) Zeitschrift fur Analytische Chemie Fresenius , vol.225 , pp. 230-247
    • Schrader, B.1    Bergmann, G.2
  • 18
    • 33845959993 scopus 로고    scopus 로고
    • Bulk Raman analysis of pharmaceutical tablets
    • Matousek P., Parker A.W. Bulk Raman analysis of pharmaceutical tablets. Appl. Spectrosc. 2006, 60:1353-1357.
    • (2006) Appl. Spectrosc. , vol.60 , pp. 1353-1357
    • Matousek, P.1    Parker, A.W.2
  • 19
    • 34248196448 scopus 로고    scopus 로고
    • Non-invasive probing of pharmaceutical capsules using transmission Raman spectroscopy
    • Matousek P., Parker A.W. Non-invasive probing of pharmaceutical capsules using transmission Raman spectroscopy. J. Raman Spectrosc. 2007, 38:563-567.
    • (2007) J. Raman Spectrosc. , vol.38 , pp. 563-567
    • Matousek, P.1    Parker, A.W.2
  • 20
    • 22744451910 scopus 로고    scopus 로고
    • Comparison of sampling techniques for in-line monitoring using Raman spectroscopy
    • Wikstrom H., Lewis I.R., Taylor L.S. Comparison of sampling techniques for in-line monitoring using Raman spectroscopy. Appl. Spectrosc. 2005, 59:934-941.
    • (2005) Appl. Spectrosc. , vol.59 , pp. 934-941
    • Wikstrom, H.1    Lewis, I.R.2    Taylor, L.S.3
  • 21
    • 33749240326 scopus 로고    scopus 로고
    • New reliable Raman collection system using the wide area illumination (WAI) scheme combined with the synchronous intensity correction standard for the analysis of pharmaceutical tablets
    • Kim M., Chung H., Woo Y.A., Kemper M.S. New reliable Raman collection system using the wide area illumination (WAI) scheme combined with the synchronous intensity correction standard for the analysis of pharmaceutical tablets. Anal. Chim. Acta 2006, 579:209-216.
    • (2006) Anal. Chim. Acta , vol.579 , pp. 209-216
    • Kim, M.1    Chung, H.2    Woo, Y.A.3    Kemper, M.S.4
  • 22
    • 34548023435 scopus 로고    scopus 로고
    • Direct, non-destructive quantitative measurement of an active pharmaceutical ingredient in an intact capsule formulation using Raman spectroscopy
    • Kim J., Noh J., Chung H., Woo Y.A., Kemper M.S., Lee Y. Direct, non-destructive quantitative measurement of an active pharmaceutical ingredient in an intact capsule formulation using Raman spectroscopy. Anal. Chim. Acta 2007, 598:280-285.
    • (2007) Anal. Chim. Acta , vol.598 , pp. 280-285
    • Kim, J.1    Noh, J.2    Chung, H.3    Woo, Y.A.4    Kemper, M.S.5    Lee, Y.6
  • 23
    • 34248643717 scopus 로고    scopus 로고
    • Reliable and fast quantitative analysis of active ingredient in pharmaceutical suspension using Raman spectroscopy
    • Park S.C., Kim M., Noh J., Chung H., Woo Y., Lee J., Kemper M.S. Reliable and fast quantitative analysis of active ingredient in pharmaceutical suspension using Raman spectroscopy. Anal. Chim. Acta 2007, 593:46-53.
    • (2007) Anal. Chim. Acta , vol.593 , pp. 46-53
    • Park, S.C.1    Kim, M.2    Noh, J.3    Chung, H.4    Woo, Y.5    Lee, J.6    Kemper, M.S.7
  • 24
    • 33847613583 scopus 로고    scopus 로고
    • A new non-invasive, quantitative Raman technique for the determination of an active ingredient in pharmaceutical liquids by direct measurement through a plastic bottle
    • Kim M., Chung H., Woo Y.A., Kemper M.S. A new non-invasive, quantitative Raman technique for the determination of an active ingredient in pharmaceutical liquids by direct measurement through a plastic bottle. Anal. Chim. Acta 2007, 587:200-207.
    • (2007) Anal. Chim. Acta , vol.587 , pp. 200-207
    • Kim, M.1    Chung, H.2    Woo, Y.A.3    Kemper, M.S.4
  • 26
    • 79955468640 scopus 로고    scopus 로고
    • Transmission Raman Spectroscopy for Robust Tablet Assessment, FACSS Conference Proceedings, (abstract 300) Louisville, Kentucky
    • J. Johansson, O. Svensson, S. Folestad, A. Sparen, M. Claybourn, Transmission Raman Spectroscopy for Robust Tablet Assessment, FACSS Conference Proceedings, (abstract 300) Louisville, Kentucky, 2009, p. 131.
    • (2009) , pp. 131
    • Johansson, J.1    Svensson, O.2    Folestad, S.3    Sparen, A.4    Claybourn, M.5
  • 28
    • 77952702821 scopus 로고    scopus 로고
    • Measurement of spatial resolution and sensitivity in transmission and backscattering Raman spectroscopy of opaque samples: impact on pharmaceutical quality control and Raman tomography
    • Everall N., Priestnall I., Dallin P., Andrews J., Lewis I., Davis K., Owen H., George M.W. Measurement of spatial resolution and sensitivity in transmission and backscattering Raman spectroscopy of opaque samples: impact on pharmaceutical quality control and Raman tomography. Appl. Spectrosc. 2010, 64:476-484.
    • (2010) Appl. Spectrosc. , vol.64 , pp. 476-484
    • Everall, N.1    Priestnall, I.2    Dallin, P.3    Andrews, J.4    Lewis, I.5    Davis, K.6    Owen, H.7    George, M.W.8
  • 29
    • 34548179643 scopus 로고    scopus 로고
    • Raman signal enhancement in deep spectroscopy of turbid media
    • Matousek P. Raman signal enhancement in deep spectroscopy of turbid media. Appl. Spectrosc. 2007, 61:845-854.
    • (2007) Appl. Spectrosc. , vol.61 , pp. 845-854
    • Matousek, P.1
  • 30
    • 51549084112 scopus 로고    scopus 로고
    • Passive signal enhancement in spatially offset Raman spectroscopy
    • Eliasson C., Matousek P. Passive signal enhancement in spatially offset Raman spectroscopy. J. Raman Spectrosc. 2008, 39:633-637.
    • (2008) J. Raman Spectrosc. , vol.39 , pp. 633-637
    • Eliasson, C.1    Matousek, P.2
  • 31
    • 49449091357 scopus 로고    scopus 로고
    • Technique for enhancing signal in conventional backscattering fluorescence and Raman spectroscopy of turbid media
    • Buckley K., Goodship A., Macleod N.A., Parker A.W., Matousek P. Technique for enhancing signal in conventional backscattering fluorescence and Raman spectroscopy of turbid media. Anal. Chem. 2008, 80:6006-6009.
    • (2008) Anal. Chem. , vol.80 , pp. 6006-6009
    • Buckley, K.1    Goodship, A.2    Macleod, N.A.3    Parker, A.W.4    Matousek, P.5
  • 32
    • 36049033659 scopus 로고    scopus 로고
    • Quantitative transmission Raman spectroscopy of pharmaceutical tablets and capsules
    • Johansson J., Sparen A., Svensson O., Folestad S., Claybourn M. Quantitative transmission Raman spectroscopy of pharmaceutical tablets and capsules. Appl. Spectrosc. 2007, 61:1211-1218.
    • (2007) Appl. Spectrosc. , vol.61 , pp. 1211-1218
    • Johansson, J.1    Sparen, A.2    Svensson, O.3    Folestad, S.4    Claybourn, M.5
  • 34
    • 79955468911 scopus 로고    scopus 로고
    • Characterisation of transmission Raman spectroscopy for rapid quantitative analysis of intact multi-component pharmaceutical capsules
    • Hargreaves M.D., Macleod N.A., Smith M.R., Andrews D., Hammond S.V., Matousek P. Characterisation of transmission Raman spectroscopy for rapid quantitative analysis of intact multi-component pharmaceutical capsules. J. Pharm. Biomed. Anal. 2010.
    • (2010) J. Pharm. Biomed. Anal.
    • Hargreaves, M.D.1    Macleod, N.A.2    Smith, M.R.3    Andrews, D.4    Hammond, S.V.5    Matousek, P.6
  • 35
    • 77955783559 scopus 로고    scopus 로고
    • Transmission Raman spectroscopy as a tool for quantifying polymorphic content of pharmaceutical formulations
    • Aina A., Hargreaves M.D., Matousek P., Burley J.C. Transmission Raman spectroscopy as a tool for quantifying polymorphic content of pharmaceutical formulations. Analyst 2010, 135:2328-2333.
    • (2010) Analyst , vol.135 , pp. 2328-2333
    • Aina, A.1    Hargreaves, M.D.2    Matousek, P.3    Burley, J.C.4
  • 36
    • 78650653309 scopus 로고    scopus 로고
    • Comparison of multivariate methods for quantitative determination with transmission Raman spectroscopy in pharmaceutical formulations
    • Fransson M., Johansson J., Sparen A., Svensson O. Comparison of multivariate methods for quantitative determination with transmission Raman spectroscopy in pharmaceutical formulations. J. Chemometr. 2010, 10.1002/cem.1330.
    • (2010) J. Chemometr.
    • Fransson, M.1    Johansson, J.2    Sparen, A.3    Svensson, O.4
  • 37
    • 0036575375 scopus 로고    scopus 로고
    • Light leakage effects with different sample holder geometries in quantitative near-infrared transmission spectroscopy of pharmaceutical tablets
    • Sparen A., Malm M., Josefson M., Folestad S., Johansson J. Light leakage effects with different sample holder geometries in quantitative near-infrared transmission spectroscopy of pharmaceutical tablets. Appl. Spectrosc. 2002, 56:586-592.
    • (2002) Appl. Spectrosc. , vol.56 , pp. 586-592
    • Sparen, A.1    Malm, M.2    Josefson, M.3    Folestad, S.4    Johansson, J.5
  • 39
    • 12344275554 scopus 로고    scopus 로고
    • Evaluation of basic algorithms for transferring quantitative multivariate calibrations between scanning grating and FT NIR spectrometers
    • Leion H., Folestad S., Josefson M., Sparen A. Evaluation of basic algorithms for transferring quantitative multivariate calibrations between scanning grating and FT NIR spectrometers. J. Pharm. Biomed. Anal. 2005, 37:47-55.
    • (2005) J. Pharm. Biomed. Anal. , vol.37 , pp. 47-55
    • Leion, H.1    Folestad, S.2    Josefson, M.3    Sparen, A.4
  • 41
    • 33645071917 scopus 로고    scopus 로고
    • Transfer of NIR calibrations for pharmaceutical formulations between different instruments
    • Bergman E.L., Brage H., Josefson M., Svensson O., Sparen A. Transfer of NIR calibrations for pharmaceutical formulations between different instruments. J. Pharm. Biomed. Anal. 2006, 41:89-98.
    • (2006) J. Pharm. Biomed. Anal. , vol.41 , pp. 89-98
    • Bergman, E.L.1    Brage, H.2    Josefson, M.3    Svensson, O.4    Sparen, A.5
  • 42
    • 0027946499 scopus 로고
    • Multivariate calibration standardisation
    • de Noord O.E. Multivariate calibration standardisation. Chemom. Intell. Lab. Syst. 1994, 25:85-97.
    • (1994) Chemom. Intell. Lab. Syst. , vol.25 , pp. 85-97
    • de Noord, O.E.1
  • 43
    • 0038259241 scopus 로고    scopus 로고
    • Standardisation and calibration transfer for near infrared instruments: a review
    • Fearn T. Standardisation and calibration transfer for near infrared instruments: a review. J. Near Infrared Spectrosc. 2001, 9:229-244.
    • (2001) J. Near Infrared Spectrosc. , vol.9 , pp. 229-244
    • Fearn, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.