메뉴 건너뛰기




Volumn 56, Issue 10, 2011, Pages 2903-2915

A novel method for incorporating respiratory-matched attenuation correction in the motion correction of cardiac PET-CT studies

Author keywords

[No Author keywords available]

Indexed keywords

ATTENUATION CORRECTION; CARDIAC ACTIVITY; DATA SETS; GOLD STANDARDS; HEART MOTION; MOTION CORRECTION; NOVEL METHODS; PERFUSION DEFECTS; PET IMAGES; QUANTITATIVE ACCURACY; RESPIRATORY EFFECTS; RIGID REGISTRATION; SEMI-AUTOMATICS; STATISTICAL SHAPE MODEL;

EID: 79955456001     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/56/10/002     Document Type: Article
Times cited : (22)

References (22)
  • 1
    • 0142094995 scopus 로고    scopus 로고
    • A generalized model for the conversion from CT numbers to linear attenuation coefficients
    • Bai C, Shao L, Silva A J D and Zhao Z 2003 A generalized model for the conversion from CT numbers to linear attenuation coefficients IEEE Trans. Nucl. Sci. 50 1510-5
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , Issue.5 , pp. 1510-1515
    • Bai, C.1    Shao, L.2    Silva, A.J.D.3    Zhao, Z.4
  • 2
    • 75149114655 scopus 로고    scopus 로고
    • Implementation of an automated respiratory amplitude gating technique for PET/CT: Clinical evaluation
    • Chang G, Chang T, Pan T, Clark J W Jr and Mawlawi O R 2010 Implementation of an automated respiratory amplitude gating technique for PET/CT: clinical evaluation J. Nucl. Med. 51 16-24
    • (2010) J. Nucl. Med. , vol.51 , Issue.1 , pp. 16-24
    • Chang, G.1    Chang, T.2    Pan, T.3    Clark Jr., J.W.4    Mawlawi, O.R.5
  • 3
    • 34249746656 scopus 로고    scopus 로고
    • Respiration-averaged CT for attenuation correction in canine cardiac PET/CT
    • DOI 10.2967/jnumed.106.034199
    • Cook R A H, Cames G, Lee T-Y and Wells R G 2007 Respiration-averaged CT for attenuation correction in canine cardiac PET/CT J. Nucl. Med. 48 811-8 (Pubitemid 47604983)
    • (2007) Journal of Nuclear Medicine , vol.48 , Issue.5 , pp. 811-818
    • Cook, R.A.H.1    Carnes, G.2    Lee, T.-Y.3    Wells, R.G.4
  • 4
    • 48549091398 scopus 로고    scopus 로고
    • Respiratory motion correction in 3-D PET data with advanced optical flow algorithms
    • Dawood M, Büther F, Jiang X and Schäfers K P 2008 Respiratory motion correction in 3-D PET data with advanced optical flow algorithms IEEE Trans. Med. Imag. 27 1164-75
    • (2008) IEEE Trans. Med. Imag. , vol.27 , Issue.8 , pp. 1164-1175
    • Dawood, M.1    Büther, F.2    Jiang, X.3    Schäfers, K.P.4
  • 6
    • 34447306296 scopus 로고    scopus 로고
    • Frequent diagnostic errors in cardiac PET/CT due to misregistration of CT attenuation and emission PET images: A definitive analysis of causes, consequences, and corrections
    • DOI 10.2967/jnumed.107.039792
    • Gould K L, Pan T, Loghin C, Johnson N P, Guha A and Sdringola S 2007 Frequent diagnostic errors in cardiac PET/CT due to misregistration of CT attenuation and emission PET images: a definitive analysis of causes, consequences, and corrections J. Nucl. Med. 48 1112-21 (Pubitemid 47052651)
    • (2007) Journal of Nuclear Medicine , vol.48 , Issue.7 , pp. 1112-1121
    • Gould, K.L.1    Pan, T.2    Loghin, C.3    Johnson, N.P.4    Guha, A.5    Sdringola, S.6
  • 7
    • 0036209759 scopus 로고    scopus 로고
    • 68Ge attenuation correction in a combined PET/CT system: Evaluation of the effect of lowering the CT tube current
    • DOI 10.1007/s00259-001-0698-9
    • Kamel E, Hany T F, Burger C, Treyer V, Lonn A H R, von Schulthess G A and Buck A 2002 CT versus 68Ge attenuation correction in a combined PET/CT system: evaluation of the effect of lowering the CT tube current Eur. J. Nucl. Med. Mol. Imag. 29 346-50 (Pubitemid 34253246)
    • (2002) European Journal of Nuclear Medicine , vol.29 , Issue.3 , pp. 346-350
    • Kamel, E.1    Hany, T.F.2    Burger, C.3    Treyer, V.4    Lonn, A.H.5    Von Schulthess, G.K.6    Buck, A.7
  • 9
    • 38349117091 scopus 로고    scopus 로고
    • CT-based attenuation correction in 82Rb-myocardial perfusion PET-CT: Incidence of misalignment and effect on regional tracer distribution
    • Lautamäki R, Brown T, Merrill J and Bengel F 2008 CT-based attenuation correction in 82Rb-myocardial perfusion PET-CT: incidence of misalignment and effect on regional tracer distribution Eur. J. Nucl. Med. Mol. Imag. 35 305-10
    • (2008) Eur. J. Nucl. Med. Mol. Imag. , vol.35 , Issue.2 , pp. 305-310
    • Lautamäki, R.1    Brown, T.2    Merrill, J.3    Bengel, F.4
  • 10
    • 22244488754 scopus 로고    scopus 로고
    • Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET
    • DOI 10.1088/0031-9155/50/14/008
    • Livieratos L, Stegger L, Bloomfield P M, Schafers K, Bailey D L and Camici P G 2005 Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET Phys. Med. Biol. 50 3313-22 (Pubitemid 40991691)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.14 , pp. 3313-3322
    • Livieratos, L.1    Stegger, L.2    Bloomfield, P.M.3    Schafers, K.4    Bailey, D.L.5    Camici, P.G.6
  • 11
    • 3242731469 scopus 로고    scopus 로고
    • Common artifacts in PET myocardial perfusion images due to attenuation-emission misregistration: Clinical significance, causes, and solutions
    • Loghin C, Sdringola S and Gould K L 2004 Common artifacts in PET myocardial perfusion images due to attenuation-emission misregistration: Clinical significance, causes, and solutions J. Nucl. Med. 45 1029-39 (Pubitemid 47611690)
    • (2004) Journal of Nuclear Medicine , vol.45 , Issue.6 , pp. 1029-1039
    • Loghin, C.1    Sdringola, S.2    Gould, K.L.3
  • 12
    • 46549088758 scopus 로고    scopus 로고
    • Contrast enhanced 4D-CT imaging for target volume definition in pancreatic ductal adenocarcinoma
    • Mancosu P et al 2008 Contrast enhanced 4D-CT imaging for target volume definition in pancreatic ductal adenocarcinoma Radiother. Oncol. 87 339-42
    • (2008) Radiother. Oncol. , vol.87 , Issue.3 , pp. 339-342
    • Mancosu, P.1
  • 13
    • 43749093413 scopus 로고    scopus 로고
    • Segmenting and tracking diaphragm and heart regions in gated-CT datasets as an aid to developing a predictive model for respiratory motion-correction
    • Martin S J, Dey J, King M A and Hutton B F 2007 Segmenting and tracking diaphragm and heart regions in gated-CT datasets as an aid to developing a predictive model for respiratory motion-correction IEEE Nucl. Sci. Symp. Conf. Rec. pp 2680-5
    • (2007) IEEE Nucl. Sci. Symp. Conf. Rec. , pp. 2680-2685
    • Martin, S.J.1    Dey, J.2    King, M.A.3    Hutton, B.F.4
  • 14
    • 34047230826 scopus 로고    scopus 로고
    • Artifacts from misaligned CT in cardiac perfusion PET/CT studies: Frequency, effects, and potential solutions
    • Martinez-Möller A, Souvatzoglou M, Navab N, Schwaiger M and Nekolla S G 2007 Artifacts from misaligned CT in cardiac perfusion PET/CT studies: frequency, effects, and potential solutions J. Nucl. Med. 48 188-93 (Pubitemid 47555342)
    • (2007) Journal of Nuclear Medicine , vol.48 , Issue.2 , pp. 188-193
    • Martinez-Moller, A.1    Souvatzoglou, M.2    Navab, N.3    Schwaiger, M.4    Nekolla, S.G.5
  • 15
    • 43749118153 scopus 로고    scopus 로고
    • Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT
    • McQuaid S J and Hutton B F 2008 Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT Eur. J. Nucl. Med. Mol. Imag. 35 1117-23
    • (2008) Eur. J. Nucl. Med. Mol. Imag. , vol.35 , Issue.6 , pp. 1117-1123
    • McQuaid, S.J.1    Hutton, B.F.2
  • 16
    • 70450233573 scopus 로고    scopus 로고
    • The application of a statistical shape model to diaphragm tracking in respiratory-gated cardiac PET images
    • McQuaid S J, Lambrou T, Cunningham V, Bettinardi V, Gilardi M C and Hutton B F 2009 The application of a statistical shape model to diaphragm tracking in respiratory-gated cardiac PET images Proc. IEEE 97 2039-52
    • (2009) Proc. IEEE , vol.97 , Issue.12 , pp. 2039-2052
    • McQuaid, S.J.1    Lambrou, T.2    Cunningham, V.3    Bettinardi, V.4    Gilardi, M.C.5    Hutton, B.F.6
  • 18
    • 34447326202 scopus 로고    scopus 로고
    • Minimizing artifacts resulting from respiratory and cardiac motion by optimization of the transmission scan in cardiac PET/CT
    • DOI 10.1118/1.2731033
    • Nye J A, Esteves F and Votaw J R 2007 Minimizing artifacts resulting from respiratory and cardiac motion by optimization of the transmission scan in cardiac PET/CT Med. Phys. 34 1901-6 (Pubitemid 47055723)
    • (2007) Medical Physics , vol.34 , Issue.6 , pp. 1901-1906
    • Nye, J.A.1    Esteves, F.2    Votaw, J.R.3
  • 19
    • 47649111099 scopus 로고    scopus 로고
    • Attenuation correction of four dimensional (4D) PET using phase-correlated 4D-computed tomography
    • DOI 10.1088/0031-9155/53/13/N03, PII S0031915508656110
    • Pönisch F, Richter C, Just U and Enghardt W 2008 Attenuation correction of four-dimensional (4D) PET using phase-correlated 4D-computed tomography Phys. Med. Biol. 53 N259-68 (Pubitemid 352020052)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.13
    • Ponisch, F.1    Richter, C.2    Just, U.3    Enghardt, W.4
  • 21
    • 77956203253 scopus 로고    scopus 로고
    • Single-phase CT aligned to gated PET for respiratory motion correction in cardiac PET/CT
    • Wells R G, Ruddy T D, DeKemp R A, DaSilver J N and Beanlands R S 2010 Single-phase CT aligned to gated PET for respiratory motion correction in cardiac PET/CT J. Nucl. Med. 51 1182-90
    • (2010) J. Nucl. Med. , vol.51 , Issue.8 , pp. 1182-1190
    • Wells, R.G.1    Ruddy, T.D.2    Dekemp, R.A.3    Dasilver, J.N.4    Beanlands, R.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.