메뉴 건너뛰기




Volumn 4, Issue , 2011, Pages 228-238

Study of mist-cooling for semi-enclosed spaces in Osaka, Japan

Author keywords

Evaporative cooling; Heat island; Mist; Spray nozzle; Urban spaces

Indexed keywords

ATMOSPHERIC TEMPERATURE; COOLING SYSTEMS; DROPS; EVAPORATION; FOG; SPRAY NOZZLES; URBAN PLANNING; WETTING;

EID: 79955442579     PISSN: None     EISSN: 18780296     Source Type: Conference Proceeding    
DOI: 10.1016/j.proenv.2011.03.027     Document Type: Conference Paper
Times cited : (35)

References (13)
  • 2
    • 0030100756 scopus 로고    scopus 로고
    • Refining the use of evaporation in an experimental down-draft cool tower
    • DOI 10.1016/0378-7788(95)00944-2
    • Pearlmutter, D., Erell E., Etzion Y., Meir I.A., & Di H. 1996. Refining the use of evaporation in an experimental down-draft cool tower. Energy and Buildings 23: 191-197. (Pubitemid 126346993)
    • (1996) Energy and Buildings , vol.23 , Issue.3 , pp. 191-197
    • Pearlmutter, D.1    Erell, E.2    Etzion, Y.3    Meir, I.A.4    Di, H.5
  • 3
    • 79955461329 scopus 로고    scopus 로고
    • Study on cooling effect with water mist sprayer: Measurement on global loop at the 2005 world exposition
    • Kanto. [in Japanese]
    • Yamada H, Okumiya M, Tsujimoto M, Harada M. (2006). Study on Cooling Effect with Water Mist Sprayer: Measurement on Global Loop at the 2005 World Exposition. Architectural Inst. of Japan Congress. Kanto. p. 677 [in Japanese]
    • (2006) Architectural Inst. of Japan Congress , pp. 677
    • Yamada, H.1    Okumiya, M.2    Tsujimoto, M.3    Harada, M.4
  • 6
    • 85031267151 scopus 로고    scopus 로고
    • retrieved 2010
    • Japan Meteorological Agency (retrieved 2010) http://www.jma.go.jp/jma/ indexe.html
  • 7
    • 85031274889 scopus 로고    scopus 로고
    • Osaka City Waterworks Bureau 2008. Water Quality Management. www.city.osaka.jp/suido/english/quality/check/qa.html.
    • (2008) Water Quality Management
  • 8
    • 0021079869 scopus 로고
    • Susceptibility of Legionella pneumophila to chlorine in tap water
    • Kuchta, J, States S. McNamara A, Wadowsky R., Yee R. (1983). Susceptibility of legionella pneumophilia to chlorine in tap water. Applied and Environmental Microbiology Vol. 46, No. 5: pp. 1134-1139. (Pubitemid 14232647)
    • (1983) Applied and Environmental Microbiology , vol.46 , Issue.5 , pp. 1134-1139
    • Kuchta, J.M.1    States, S.J.2    McNamara, A.M.3
  • 10
    • 79955417505 scopus 로고    scopus 로고
    • A proposal for mist cooling control and measurement methods
    • [in Japanese]
    • Farnham C, Nakao M, Nishioka M, Nabeshima M, Mizuno T. (2009) A Proposal for Mist Cooling Control and Measurement Methods. Trans. Of the JSRAE. Vol. 26, No. 1. Pp. 105-112. [in Japanese]
    • (2009) Trans. of the JSRAE , vol.26 , Issue.1 , pp. 105-112
    • Farnham, C.1    Nakao, M.2    Nishioka, M.3    Nabeshima, M.4    Mizuno, T.5
  • 12
    • 0003842308 scopus 로고    scopus 로고
    • ASHRAE. Ch. 8 Thermal Comfort. Atlanta
    • ASHRAE (2005). ASHRAE Handbook - Fundamentals. Ch. 8 Thermal Comfort. Atlanta.
    • (2005) ASHRAE Handbook - Fundamentals
  • 13
    • 85031255671 scopus 로고    scopus 로고
    • Japan Building Mechanical and Electrical Engineers Assoc. (1992). HASP/ACSS/8502 Program Manual. Tokyo. (in Japanese)
    • Japan Building Mechanical and Electrical Engineers Assoc. (1992). HASP/ACSS/8502 Program Manual. Tokyo. (in Japanese).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.