메뉴 건너뛰기




Volumn 33, Issue 5, 2011, Pages 1209-1217

Local specific absorption rate in high-pass birdcage and transverse electromagnetic body coils for multiple human body models in clinical landmark positions at 3T

Author keywords

human body models; local SAR; SAR; specific absorption rate

Indexed keywords

ARTICLE; ELECTROMAGNETIC FIELD; FEMALE; HUMAN; IMAGE ANALYSIS; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RADIOFREQUENCY; TRANSMISSION ELECTRON MICROSCOPY; WHOLE BODY IMAGING;

EID: 79955397165     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.22544     Document Type: Article
Times cited : (48)

References (20)
  • 1
    • 0034848047 scopus 로고    scopus 로고
    • Sampling and evaluation of specific absorption rates during patient examinations performed on 1.5-Tesla MR systems
    • DOI 10.1016/S0730-725X(01)00395-2, PII S0730725X01003952
    • Brix G, Reinl M, Brinker G,. Sampling and evaluation of specific absorption rates during patient examinations performed on 1.5-Tesla MR systems. Magn Reson Imaging 2001; 19: 769-779. (Pubitemid 32845943)
    • (2001) Magnetic Resonance Imaging , vol.19 , Issue.6 , pp. 769-779
    • Brix, G.1    Reinl, M.2    Brinker, G.3
  • 3
    • 0036223150 scopus 로고    scopus 로고
    • Estimation of heat transfer and temperature rise in partial-body regions during MR procedures: An analytical approach with respect to safety considerations
    • DOI 10.1016/S0730-725X(02)00483-6, PII S0730725X02004836
    • Brix G, Seebass M, Hellwig G, Griebel J,. Estimation of heat transfer and temperature rise in partial-body regions during MR procedures: an analytical approach with respect to safety considerations. Magn Reson Imaging 2002; 20: 65-76. (Pubitemid 34309133)
    • (2002) Magnetic Resonance Imaging , vol.20 , Issue.1 , pp. 65-76
    • Brix, G.1    Seebass, M.2    Hellwig, G.3    Griebel, J.4
  • 5
    • 0033945956 scopus 로고    scopus 로고
    • Sensitivity and power deposition in a high-field imaging experiment
    • Hoult DI,. Sensitivity and power deposition in a high-field imaging experiment. J Magn Reson Imaging 2000; 12: 46-67. (Pubitemid 30437264)
    • (2000) Journal of Magnetic Resonance Imaging , vol.12 , Issue.1 , pp. 46-67
    • Hoult, D.I.1    Phil, D.2
  • 6
    • 0035685766 scopus 로고    scopus 로고
    • Effect of RF coil excitation on field inhomogeneity at ultra high fields: A field optimized TEM resonatior
    • DOI 10.1016/S0730-725X(01)00404-0, PII S0730725X01004040
    • Ibrahim TS, Lee R, Baertlein A, Abduljalil AM, Zhu H, Robitaille PL,. Effect of RF coil excitation on field inhomogeneity at ultra high fields: a field optimized TEM resonator. Magn Reson Med 2001; 19: 1339-47. (Pubitemid 34081298)
    • (2001) Magnetic Resonance Imaging , vol.19 , Issue.10 , pp. 1339-1347
    • Ibrahim, T.S.1    Lee, R.2    Baertlein, B.A.3    Abduljalil, A.M.4    Zhu, H.5    Robitaille, P.-M.L.6
  • 8
    • 1842586446 scopus 로고    scopus 로고
    • Parallel Excitation with an Array of Transmit Coils
    • DOI 10.1002/mrm.20011
    • Zhu Y,. Parallel excitation with an array of transmit coils. Magn Reson Med 2004; 51: 775-784. (Pubitemid 38420455)
    • (2004) Magnetic Resonance in Medicine , vol.51 , Issue.4 , pp. 775-784
    • Zhu, Y.1
  • 10
    • 0035088714 scopus 로고    scopus 로고
    • 1 distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model
    • DOI 10.1002/mrm.1092
    • Collins CM, Smith MB,. Calculations of B1 distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model. Magn Reson Imaging 2001; 45: 692-699. (Pubitemid 32260092)
    • (2001) Magnetic Resonance in Medicine , vol.45 , Issue.4 , pp. 692-699
    • Collins, C.M.1    Smith, M.B.2
  • 11
    • 26044442541 scopus 로고    scopus 로고
    • 1 distribution, specific energy absorption rate, and intrinsic signal-to-noise ratio for a body-size birdcage coil loaded with different human subjects at 64 and 128 MHz
    • Liu W, Collins CM, Smith MB,. Calculations of B1 distribution, specific energy absorption rate, and intrinsic signal-to-noise ratio for a body-size birdcage coil loaded with different human subjects at 64 and 128 MHz. Appl Magn Reson 2005; 29: 5-18. (Pubitemid 41405608)
    • (2005) Applied Magnetic Resonance , vol.29 , Issue.1 , pp. 5-18
    • Liu, W.1    Collins, C.M.2    Smith, M.B.3
  • 17
    • 0031910772 scopus 로고    scopus 로고
    • Induced current densities from low-frequency magnetic fields in a 2 mm resolution, anatomically realistic model of the body
    • DOI 10.1088/0031-9155/43/2/001, PII S0031915598877737
    • Dimbylow PJ,. Induced current densities from low-frequency magnetic fields in a 2 mm resolution, anatomically realistic model of the body. Phys Med Biol 1998; 43: 221-230. (Pubitemid 28100128)
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.2 , pp. 221-230
    • Dimbylow, P.J.1
  • 18
    • 16444369285 scopus 로고    scopus 로고
    • Development of the female voxel phantom, NAOMI, and its application to calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields
    • DOI 10.1088/0031-9155/50/6/002
    • Dimbylow P,. Development of the female voxel phantom, NAOMI, and its application to calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields. Phys Med Biol 2005; 50: 1047-1070. (Pubitemid 40477279)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.6 , pp. 1047-1070
    • Dimbylow, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.