-
1
-
-
84927026215
-
-
Cambridge, UK: Cambridge University Press;. p.
-
Gillard JH, Graves MJ, Hatsukami TS, Yuan C,. Carotid disease: the role of imaging in diagnosis and management. Cambridge, UK: Cambridge University Press; 2007. 532 p.
-
(2007)
Carotid Disease: The Role of Imaging in Diagnosis and Management
, pp. 532
-
-
Gillard, J.H.1
Graves, M.J.2
Hatsukami, T.S.3
Yuan, C.4
-
2
-
-
0034756429
-
Carotid atherosclerotic plaque: Noninvasive MR characterization and identification of vulnerable lesions
-
Yuan C, Mitsumori LM, Beach KW, Maravilla KR,. Carotid atherosclerotic plaque: noninvasive MR characterization and identification of vulnerable lesions. Radiology 2001; 221: 285-299. (Pubitemid 33043408)
-
(2001)
Radiology
, vol.221
, Issue.2
, pp. 285-299
-
-
Yuan, C.1
Mitsumori, L.M.2
Beach, K.W.3
Maravilla, K.R.4
-
3
-
-
20044374365
-
High resolution multi-contrast MRI of the carotid artery wall for the evaluation of atherosclerotic plaques
-
Yarnykh VL, Yuan C,. High resolution multi-contrast MRI of the carotid artery wall for the evaluation of atherosclerotic plaques. Curr Prot Magn Reson Imaging 2003; 1: A1.4.1-A1.4.17.
-
(2003)
Curr Prot Magn Reson Imaging
, vol.1
-
-
Yarnykh, V.L.1
Yuan, C.2
-
4
-
-
0037056102
-
Classification of human carotid atherosclerotic lesions with in vivo multicontrast magnetic resonance imaging
-
DOI 10.1161/01.CIR.0000028591.44554.F9
-
Cai JM, Hatsukami TS, Ferguson MS, Small R, Polissar NL, Yuan C,. Classification of human carotid atherosclerotic lesions with in vivo multicontrast magnetic resonance imaging. Circulation 2002; 106: 1368-1373. (Pubitemid 35013040)
-
(2002)
Circulation
, vol.106
, Issue.11
, pp. 1368-1373
-
-
Cai, J.-M.1
Hatsukami, T.S.2
Ferguson, M.S.3
Small, R.4
Polissar, N.L.5
Yuan, C.6
-
5
-
-
11144233333
-
Quantitative evaluation of carotid plaque composition by in vivo MRI
-
DOI 10.1161/01.ATV.0000149867.61851.31
-
Saam T, Ferguson MS, Yarnykh VL, et al. Quantitative evaluation of carotid plaque composition by in vivo MRI. Arterioscler Thromb Vasc Biol 2005; 25: 234-239. (Pubitemid 40054282)
-
(2005)
Arteriosclerosis, Thrombosis, and Vascular Biology
, vol.25
, Issue.1
, pp. 234-239
-
-
Saam, T.1
Ferguson, M.S.2
Yarnykh, V.L.3
Takaya, N.4
Xu, D.5
Polissar, N.L.6
Hatsukami, T.S.7
Yuan, C.8
-
6
-
-
0032924259
-
Closed contour edge detection of blood vessel lumen and outer wall boundaries in black-blood MR images
-
DOI 10.1016/S0730-725X(98)00162-3, PII S0730725X98001623
-
Yuan C, Lin E, Millard J, Hwang J,. Closed contour edge detection of blood vessel lumen and outer wall boundaries in black-blood MR images. Magn Reson Imaging 1999; 17: 257-266. (Pubitemid 29053185)
-
(1999)
Magnetic Resonance Imaging
, vol.17
, Issue.2
, pp. 257-266
-
-
Yuan, C.1
Lin, E.2
Millard, J.3
Hwang, J.-N.4
-
7
-
-
84958170369
-
A Quantitative Vascular Analysis System for Evaluation of Atherosclerotic Lesions by MRI
-
Medical Image Computing and Computer-Assisted Intervention - MICCAI 2001
-
Kerwin WS, Han C, Chu B, et al. A Quantitative vascular analysis system for evaluation of atherosclerotic lesions by MRI. Med Image Comput Comput Assist Interv 2001; 2208: 786-794. (Pubitemid 33352483)
-
(2001)
Lecture Notes in Computer Science
, Issue.2208
, pp. 786-794
-
-
Kerwin, W.1
Han, C.2
Chu, B.3
Xu, D.4
Luo, Y.5
Hwang, J.-N.6
Hatsukami, T.7
Yuan, C.8
-
8
-
-
11144280624
-
Accuracy of quantitative MR vessel wall imaging applying a semi-automated gradient detection algorithm - A validation study
-
DOI 10.1081/JCMR-200036198
-
Wang Q, Robson MD, Francis JM, et al. Accuracy of quantitative MR vessel wall imaging applying a semi-automated gradient detection algorithm-a validation study. J Cardiovasc Magn Reson 2004; 6: 895-907. (Pubitemid 40041294)
-
(2004)
Journal of Cardiovascular Magnetic Resonance
, vol.6
, Issue.4
, pp. 895-907
-
-
Wang, Q.1
Robson, M.D.2
Francis, J.M.3
Petersen, S.E.4
Channon, K.M.5
Neubauer, S.6
Wiesmann, F.7
-
9
-
-
33845336163
-
Evaluation of carotid artery wall volume measurement using novel semiautomated analysis software
-
DOI 10.1002/jmri.20798
-
Varghese A, Merrifield RD, Crowe LA, et al. Evaluation of carotid artery wall volume measurement using novel semiautomated analysis software. J Magn Reson Imaging 2006; 24; 1401-1408. (Pubitemid 44871888)
-
(2006)
Journal of Magnetic Resonance Imaging
, vol.24
, Issue.6
, pp. 1401-1408
-
-
Varghese, A.1
Merrifield, R.D.2
Crowe, L.A.3
Collins, S.A.4
Keenan, N.G.J.5
Firmin, D.N.6
Guang, Z.Y.7
Pennell, D.J.8
-
10
-
-
33947187286
-
Validation study of a semi-automated program for quantification of atherosclerotic burden
-
DOI 10.1080/10976640601015292, PII 772835758
-
Choi BG, Novoselsky CA, Vilahur G, et al. Validation study of a semi-automated program for quantification of atherosclerotic burden. J Cardiovasc Magn Reson 2007; 9: 615-620. (Pubitemid 46399018)
-
(2007)
Journal of Cardiovascular Magnetic Resonance
, vol.9
, Issue.3
, pp. 615-620
-
-
Choi, B.G.1
Novoselsky, C.A.2
Vilahur, G.3
Viles-Gonzalez, J.F.4
Zafar, M.U.5
Ibanez, B.6
Fuster, V.7
Badimon, J.J.8
-
12
-
-
0026770295
-
Factors influencing contrast in fast spin-echo MR imaging
-
Constable RT, Anderson AW, Zhong J, Gore JC,. Factors influencing contrast in fast spin-echo MR imaging. Magn Reson Imaging 1992; 10: 497-511.
-
(1992)
Magn Reson Imaging
, vol.10
, pp. 497-511
-
-
Constable, R.T.1
Anderson, A.W.2
Zhong, J.3
Gore, J.C.4
-
13
-
-
0026467251
-
The loss of small objects in variable TE imaging: Implications for FSE, RARE, and EPI
-
Constable RT, Gore JC,. The loss of small objects in variable TE imaging: implications for FSE, RARE, and EPI. Magn Reson Med 1992; 28: 9-24.
-
(1992)
Magn Reson Med
, vol.28
, pp. 9-24
-
-
Constable, R.T.1
Gore, J.C.2
-
15
-
-
0029809781
-
Magnetic resonance images lipid, fibrous, calcified, hemorrhagic, and thrombotic components of human atherosclerosis in vivo
-
Toussaint JF, LaMuraglia GM, Southern JF, Fuster V, Kantor HL,. Magnetic resonance images lipid, fibrous, calcified, hemorrhagic, and thrombotic components of human atherosclerosis in vivo. Circulation 1996; 94: 932-938. (Pubitemid 26292843)
-
(1996)
Circulation
, vol.94
, Issue.5
, pp. 932-938
-
-
Toussaint, J.-F.1
LaMuraglia, G.M.2
Southern, J.F.3
Fuster, V.4
Kantor, H.L.5
-
16
-
-
0041758454
-
Discrimination of components in atherosclerotic plaques from human carotid endarterectomy specimens by magnetic resonance imaging ex vivo
-
DOI 10.1016/S0730-725X(02)00643-4
-
Morrisett J, Vick W, Sharma R, et al. Discrimination of components in atherosclerotic plaques from human carotid endarterectomy specimens by magnetic resonance imaging ex vivo. Magn Reson Imaging 2003; 21: 465-474. (Pubitemid 36899078)
-
(2003)
Magnetic Resonance Imaging
, vol.21
, Issue.5
, pp. 465-474
-
-
Morrisett, J.1
Vick, W.2
Sharma, R.3
Lawrie, G.4
Reardon, M.5
Ezell, E.6
Schwartz, J.7
Hunter, G.8
Gorenstein, D.9
-
17
-
-
2142774039
-
Hemorrhage in the atherosclerotic carotid plaque: A high-resolution MRI study
-
DOI 10.1161/01.STR.0000125856.25309.86
-
Chu B, Kampschulte A, Ferguson MS, et al. Hemorrhage in the atherosclerotic carotid plaque: a high-resolution MRI study. Stroke 2004; 35: 1079-1084. (Pubitemid 38543521)
-
(2004)
Stroke
, vol.35
, Issue.5
, pp. 1079-1084
-
-
Chu, B.1
Kampschulte, A.2
Ferguson, M.S.3
Kerwin, W.S.4
Yarnykh, V.L.5
O'Brien, K.D.6
Polissar, N.L.7
Hatsukami, T.S.8
Yuan, C.9
-
18
-
-
33746263986
-
Comparison of symptomatic and asymptomatic atherosclerotic carotid plaque features with in vivo MR imaging
-
DOI 10.1148/radiol.2402050390
-
Saam T, Cai J, Ma L, et al. Comparison of symptomatic and asymptomatic atherosclerotic carotid plaque features with in vivo MR imaging. Radiology 2006; 240: 464-472. (Pubitemid 44098643)
-
(2006)
Radiology
, vol.240
, Issue.2
, pp. 464-472
-
-
Saam, T.1
Cai, J.2
Ma, L.3
Cai, Y.-Q.4
Ferguson, M.S.5
Polissar, N.L.6
Hatsukami, T.S.7
Yuan, C.8
-
19
-
-
53549086140
-
Signal features of the atherosclerotic plaque at 3.0 Tesla versus 1.5 Tesla: Impact on automatic classification
-
et al.
-
Kerwin WS, Liu F, Yarnykh VL, et al. Signal features of the atherosclerotic plaque at 3.0 Tesla versus 1.5 Tesla: impact on automatic classification. J Magn Reson Imaging 2008; 28: 987-995.
-
(2008)
J Magn Reson Imaging
, vol.28
, pp. 987-995
-
-
Kerwin, W.S.1
Liu, F.2
Yarnykh, V.L.3
-
20
-
-
77955627553
-
High resolution carotid black-blood 3T MR with parallel imaging and dedicated 4-channel surface coils
-
et al.
-
Saam T, Raya JG, Cyran CC, et al. High resolution carotid black-blood 3T MR with parallel imaging and dedicated 4-channel surface coils. J Cardiovasc Magn Reson 2009; 11: 41-52.
-
(2009)
J Cardiovasc Magn Reson
, vol.11
, pp. 41-52
-
-
Saam, T.1
Raya, J.G.2
Cyran, C.C.3
-
22
-
-
0011211869
-
The nature and evaluation of the sharpness of photographic images
-
Higgins GC, Jones LA,. The nature and evaluation of the sharpness of photographic images. J Soc Motion Picture Television Eng 1952; 58: 277-290.
-
(1952)
J Soc Motion Picture Television Eng
, vol.58
, pp. 277-290
-
-
Higgins, G.C.1
Jones, L.A.2
-
23
-
-
0040932542
-
Methods of appraising photographic systems
-
Perrin FH,. Methods of appraising photographic systems. J Soc Motion Picture Television Eng 1960; 69: 151-156.
-
(1960)
J Soc Motion Picture Television Eng
, vol.69
, pp. 151-156
-
-
Perrin, F.H.1
-
24
-
-
0029237814
-
Algorithm for the computation of region-based image edge profile acutance
-
Rangayyan RM, Elkadiki SG,. Algorithm for the computation of region-based image edge profile acutance. J Electron Imaging 1995; 4: 62-70.
-
(1995)
J Electron Imaging
, vol.4
, pp. 62-70
-
-
Rangayyan, R.M.1
Elkadiki, S.G.2
-
25
-
-
0034287385
-
Gradient and texture analysis for the classification of mammographic masses
-
Mudigonda NR, Rangayyan RM, Desautels JE,. Gradient and texture analysis for the classification of mammographic masses. IEEE Trans Med Imaging 2000; 19: 1032-1043.
-
(2000)
IEEE Trans Med Imaging
, vol.19
, pp. 1032-1043
-
-
Mudigonda, N.R.1
Rangayyan, R.M.2
Desautels, J.E.3
-
26
-
-
0029703323
-
Subjective and objective evaluation of image sharpness: Behavior of the region-based image edge profile acutance measure
-
Delgado-Olabarriaga S, Rangayyan RM,. Subjective and objective evaluation of image sharpness: behavior of the region-based image edge profile acutance measure. Proc SPIE 1996; 2712: 154-162.
-
(1996)
Proc SPIE
, vol.2712
, pp. 154-162
-
-
Delgado-Olabarriaga, S.1
Rangayyan, R.M.2
-
27
-
-
1842433586
-
Parallel and Nonparallel Simultaneous Multislice Black-Blood Double Inversion Recovery Techniques for Vessel Wall Imaging
-
DOI 10.1002/jmri.20022
-
Itskovich V, Mani V, Mizsei G, et al. Parallel and nonparallel simultaneous multislice black-blood double inversion recovery techniques for vessel wall imaging. J Magn Reson Imaging 2004; 19: 459-467. (Pubitemid 38437154)
-
(2004)
Journal of Magnetic Resonance Imaging
, vol.19
, Issue.4
, pp. 459-467
-
-
Itskovich, V.V.1
Mani, V.2
Mizsei, G.3
Aguinaldo, J.G.S.4
Samber, D.D.5
Macaluso, F.6
Wisdom, P.7
Fayad, Z.A.8
|