메뉴 건너뛰기




Volumn 12, Issue 5, 2011, Pages 328-333

Head-to-head comparison of early vessel healing by optical coherence tomography after implantation of different stents in the same patient

Author keywords

optical coherence tomography; stent coverage; vessel healing

Indexed keywords

ACETYLSALICYLIC ACID; CHROMIUM; CLOPIDOGREL; COBALT; FIBRINOGEN RECEPTOR ANTAGONIST; HEPARIN; PACLITAXEL; RAPAMYCIN;

EID: 79955377243     PISSN: 15582027     EISSN: None     Source Type: Journal    
DOI: 10.2459/JCM.0b013e3283406428     Document Type: Article
Times cited : (9)

References (16)
  • 2
    • 34248219973 scopus 로고    scopus 로고
    • Pathological correlates of late drug-eluting stent thrombosis: Strut coverage as a marker of endothelialization
    • DOI 10.1161/CIRCULATIONAHA.107.693739
    • Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, et al. Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 2007; 115:2435-2441. (Pubitemid 46717966)
    • (2007) Circulation , vol.115 , Issue.18 , pp. 2435-2441
    • Finn, A.V.1    Joner, M.2    Nakazawa, G.3    Kolodgie, F.4    Newell, J.5    John, M.C.6    Gold, H.K.7    Virmani, R.8
  • 3
    • 62249190368 scopus 로고    scopus 로고
    • First-in-man 1-year clinical outcomes of the Catania Coronary Stent System with nanothin Polyzene-F in de novo native coronary artery lesions: The ATLANTA (Assessment of the LAtest Non- Thrombogenic Angioplasty stent) trial
    • Tamburino C, La Manna A, Di Salvo ME, Sacchetta G, Capodanno D, Mehran R, et al. First-in-man 1-year clinical outcomes of the Catania Coronary Stent System with nanothin Polyzene-F in de novo native coronary artery lesions: the ATLANTA (Assessment of The LAtest Non- Thrombogenic Angioplasty stent) trial. JACC Cardiovasc Interv 2009; 2:197-204.
    • (2009) JACC Cardiovasc Interv , vol.2 , pp. 197-204
    • Tamburino, C.1    La Manna, A.2    Di Salvo, M.E.3    Sacchetta, G.4    Capodanno, D.5    Mehran, R.6
  • 4
    • 65649097245 scopus 로고    scopus 로고
    • Optical coherence tomographic results at six-month follow-up evaluation of the CATANIA coronary stent system with nanothin Polyzene-F surface modification (from the Assessment of the LAtest Non- Thrombogenic Angioplasty Stent [ATLANTA] trial)
    • La Manna A, Capodanno D, Cera M, Di Salvo ME, Sacchetta G, Corcos T, et al. Optical coherence tomographic results at six-month follow-up evaluation of the CATANIA coronary stent system with nanothin Polyzene-F surface modification (from the Assessment of The LAtest Non- Thrombogenic Angioplasty Stent [ATLANTA] trial). Am J Cardiol 2009; 103:1551-1555.
    • (2009) Am J Cardiol , vol.103 , pp. 1551-1555
    • La Manna, A.1    Capodanno, D.2    Cera, M.3    Di Salvo, M.E.4    Sacchetta, G.5    Corcos, T.6
  • 6
    • 77955474924 scopus 로고    scopus 로고
    • Comparison of optical coherence tomography and intravascular ultrasound for the assessment of in-stent tissue coverage after stent implantation
    • Capodanno D, Prati F, Pawlowsky T, Cera M, La Manna A, Albertucci M, et al. Comparison of optical coherence tomography and intravascular ultrasound for the assessment of in-stent tissue coverage after stent implantation. EuroIntervention 2009; 5:538-543.
    • (2009) EuroIntervention , vol.5 , pp. 538-543
    • Capodanno, D.1    Prati, F.2    Pawlowsky, T.3    Cera, M.4    La Manna, A.5    Albertucci, M.6
  • 8
    • 34147135208 scopus 로고    scopus 로고
    • Evaluation by Optical Coherence Tomography of Neointimal Coverage of Sirolimus-Eluting Stent Three Months After Implantation
    • DOI 10.1016/j.amjcard.2006.11.068, PII S0002914907000781
    • Takano M, Inami S, Jang IK, Yamamoto M, Murakami D, Seimiya K, et al. Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation. Am J Cardiol 2007; 99:1033-1038. (Pubitemid 46560470)
    • (2007) American Journal of Cardiology , vol.99 , Issue.8 , pp. 1033-1038
    • Takano, M.1    Inami, S.2    Jang, I.-K.3    Yamamoto, M.4    Murakami, D.5    Seimiya, K.6    Ohba, T.7    Mizuno, K.8
  • 9
    • 51749118724 scopus 로고    scopus 로고
    • Comparison of neointimal coverage by optical coherence tomography of a sirolimus-eluting stent versus a bare-metal stent three months after implantation
    • Xie Y, Takano M, Murakami D, Yamamoto M, Okamatsu K, Inami S, et al. Comparison of neointimal coverage by optical coherence tomography of a sirolimus-eluting stent versus a bare-metal stent three months after implantation. Am J Cardiol 2008; 102:27-31.
    • (2008) Am J Cardiol , vol.102 , pp. 27-31
    • Xie, Y.1    Takano, M.2    Murakami, D.3    Yamamoto, M.4    Okamatsu, K.5    Inami, S.6
  • 11
    • 77449097202 scopus 로고    scopus 로고
    • Properties and clinical development of a novel coating technology: The poly[bis(trifluoroethoxy)phosphazene]
    • Capodanno D, Tamburino C. Properties and clinical development of a novel coating technology: the poly[bis(trifluoroethoxy)phosphazene]. Recent Pat Drug Deliv Formul 2010; 4:18-22.
    • (2010) Recent Pat Drug Deliv Formul , vol.4 , pp. 18-22
    • Capodanno, D.1    Tamburino, C.2
  • 12
    • 0024597953 scopus 로고
    • Effect of albumin coating on the in vitro blood compatibility of Dacron® arterial prostheses
    • DOI 10.1016/0142-9612(89)90017-3
    • Kottke-Marchant K, Anderson JM, Umemura Y, Marchant RE. Effect of albumin coating on the in vitro blood compatibility of Dacron arterial prostheses. Biomaterials 1989; 10:147-155. (Pubitemid 19120668)
    • (1989) Biomaterials , vol.10 , Issue.3 , pp. 147-155
    • Kottke-Marchant, K.1    Anderson, J.M.2    Umemura, Y.3    Marchant, R.E.4
  • 13
    • 0019037146 scopus 로고
    • The interaction of plasma proteins with polymers. I. Relationship between polymer surface energy and protein adsorption/desorption
    • Baszkin A, Lyman DJ. The interaction of plasma proteins with polymers. I. Relationship between polymer surface energy and protein adsorption/ desorption. J Biomed Mater Res 1980; 14:393-403. (Pubitemid 10086162)
    • (1980) Journal of Biomedical Materials Research , vol.14 , Issue.4 , pp. 393-403
    • Baszkin, A.1    Lyman, D.J.2
  • 14
    • 80052388134 scopus 로고
    • Is the Vroman effect of importance in the interaction of blood with artificial materials?
    • Leonard EF, Vroman L. Is the Vroman effect of importance in the interaction of blood with artificial materials? J Biomater Sci Polym Ed 1991; 3:95-107.
    • (1991) J Biomater Sci Polym Ed , vol.3 , pp. 95-107
    • Leonard, E.F.1    Vroman, L.2
  • 15
    • 0034944058 scopus 로고    scopus 로고
    • The 2001 Charles T. Dotter lecture: Understanding vascular devices at the molecular level is the key to progress
    • Palmaz JC. The 2001 Charles T. Dotter lectures: understanding vascular devices at the molecular level is the key to progress. J Vasc Interv Radiol 2001; 12:789-794. (Pubitemid 32642428)
    • (2001) Journal of Vascular and Interventional Radiology , vol.12 , Issue.7 , pp. 789-794
    • Palmaz, J.C.1
  • 16
    • 70349776200 scopus 로고    scopus 로고
    • Early and mid-term clinical outcomes with the CATANIA coronary stent system vs. bare metal stents in patients with coronary artery disease
    • Capodanno D, La Manna A, Di Salvo ME, Sanfilippo A, Corcos T, Tamburino C. Early and mid-term clinical outcomes with the CATANIA coronary stent system vs. bare metal stents in patients with coronary artery disease. Cardiovasc Revasc Med 2009; 10:216-20.
    • (2009) Cardiovasc Revasc Med , vol.10 , pp. 216-220
    • Capodanno, D.1    La Manna, A.2    Di Salvo, M.E.3    Sanfilippo, A.4    Corcos, T.5    Tamburino, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.