메뉴 건너뛰기




Volumn 63, Issue 5, 2011, Pages 1044-1052

CSO management from an operator's perspective: A step-wise action plan

Author keywords

Combined sewer overflows; Disconnection; Modelling; Monitoring; Real time control; Storage tanks; Throttle structures

Indexed keywords

COMBINED SEWER OVERFLOWS; DISCONNECTION; MODELLING; STORAGE TANKS; THROTTLE STRUCTURES;

EID: 79955365601     PISSN: 02731223     EISSN: None     Source Type: Journal    
DOI: 10.2166/wst.2011.288     Document Type: Article
Times cited : (20)

References (17)
  • 2
    • 79955434221 scopus 로고    scopus 로고
    • Model-based optimisation of integrated urban wastewater systems (iMOD) Deficit analyis - Case study Kessel-Lo
    • Blumensaat, F., Tränckner, J., Kroll, S. & Dirckx, G. 2007 Model-based optimisation of integrated urban wastewater systems (iMOD) Deficit analyis - case study Kessel-Lo. Aquafin NV report.
    • (2007) Aquafin NV Report
    • Blumensaat, F.1    Tränckner, J.2    Kroll, S.3    Dirckx, G.4
  • 4
    • 15544364951 scopus 로고    scopus 로고
    • A new database on urban runoff pollution: Comparison of separate and combined sewer systems
    • Brombach, H., Weiss, G. & Fuchs, S. 2005 A new database on urban runoff pollution: comparison of separate and combined systems. Water Science and Technology 51(2), 119-128. (Pubitemid 40403110)
    • (2005) Water Science and Technology , vol.51 , Issue.2 , pp. 119-128
    • Brombach, H.1    Weiss, G.2    Fuchs, S.3
  • 6
    • 37049001853 scopus 로고    scopus 로고
    • Suitability of CSO performance indicators for compliance with ambient water quality targets
    • Engelhard, C., De Toffol, S. & Rauch, W. 2008 Suitability of CSO performance indicators for compliance with ambient water quality targets. Urban Water Journal 5(1), 41-47.
    • (2008) Urban Water Journal , vol.5 , Issue.1 , pp. 41-47
    • Engelhard, C.1    De Toffol, S.2    Rauch, W.3
  • 7
    • 77649227152 scopus 로고    scopus 로고
    • Determining the spill flow discharge of combined sewer overflows using rating curves based on computational fluid dynamics instead of the standard weir equation
    • Fach, S., Sitzenfrei, R. & Rauch, W. 2009 Determining the spill flow discharge of combined sewer overflows using rating curves based on computational fluid dynamics instead of the standard weir equation. Water Science and Technology 60(12), 3035-3043.
    • (2009) Water Science and Technology , vol.60 , Issue.12 , pp. 3035-3043
    • Fach, S.1    Sitzenfrei, R.2    Rauch, W.3
  • 8
    • 79955444083 scopus 로고    scopus 로고
    • Gewässerschutz Bei Entlastungsbauwerken der Mischkanalisation
    • in German. Wien. Eng. title
    • Fenz, R. 2002 Gewässerschutz bei Entlastungsbauwerken der Mischkanalisation (in German). Wiener Mitteilungen, 174, Wien. Eng. title: Water pollution control at CSOs.
    • (2002) Wiener Mitteilungen , pp. 174
    • Fenz, R.1
  • 9
    • 31844437049 scopus 로고    scopus 로고
    • Continuous monitoring in sewer networks an aproach for quantification of pollution loads from CSOs into surface water bodies
    • DOI 10.1016/j.solmat.2004.08.011
    • Grüber, G., Winkler, S. & Pressl, A. 2005 Continuous monitoring in sewer networks an approach for quantification of pollution loads from CSOs into surface water bodies. Water Science and Technology 52(12), 215-223. (Pubitemid 43180693)
    • (2005) Water Science and Technology , vol.52 , Issue.12 , pp. 215-223
    • Gruber, G.1    Winkler, S.2    Pressl, A.3
  • 12
    • 79955374507 scopus 로고    scopus 로고
    • Automated model build-up and calibration of conceptual models for backwater influenced sewer systems
    • submitted for publication
    • Kroll, S., Wambecq, T., Thoeye, C., De Gueldre, G., Van De Steene, B. & Willems, P. 2010 Automated model build-up and calibration of conceptual models for backwater influenced sewer systems. Journal of Hydroinformatics (submitted for publication).
    • (2010) Journal of Hydroinformatics
    • Kroll, S.1    Wambecq, T.2    Thoeye, C.3    De Gueldre, G.4    Van De Steene, B.5    Willems, P.6
  • 13
    • 0036268143 scopus 로고    scopus 로고
    • Is combined sewer overflow spill frequency/volume a good indicator of receiving water quality impact?
    • Lau, J., Butler, D. & Schütze, M. 2002 Is combined sewer overflow spill frequency/volume a good indicator of receiving water quality impact? Urban Water 4(2), 181-189.
    • (2002) Urban Water , vol.4 , Issue.2 , pp. 181-189
    • Lau, J.1    Butler, D.2    Schütze, M.3
  • 15
    • 12344289615 scopus 로고    scopus 로고
    • Einsatz von Online-Messgeräten zur Beurteilung der Mischwasserqualität im Kanal
    • Eng. title
    • Scheer, M. & Schilling, W. 2003 Einsatz von Online-Messgeräten zur Beurteilung der Mischwasserqualität im Kanal. KA Abwasser Abfall 50(5), 585-595. Eng. title: Use of online measurement equipment to assess the quality of combined sewage in sewers.
    • (2003) KA Abwasser Abfall , vol.50 , Issue.5 , pp. 585-595
    • Scheer, M.1    Schilling, W.2
  • 16
    • 79955394633 scopus 로고    scopus 로고
    • Huidig en toekomstig gebruik van rioolmodellen in Vlaanderen
    • (in Dutch). Eng. title
    • Van Assel, J. & Dirckx, G. 2007 Huidig en toekomstig gebruik van rioolmodellen in Vlaanderen (in Dutch). TS Water. Eng. title: Current and future use of sewer models in Flanders.
    • (2007) TS Water
    • Van Assel, J.1    Dirckx, G.2
  • 17
    • 0034942050 scopus 로고    scopus 로고
    • Approaches adopted by the European Union and selected Member States for the control of urban pollution
    • Zabel, T., Milne, I. & Mckay, G. 2001 Approaches adopted by the European Union and selected Member States for the control of urban pollution. Urban Water 3(1), 25-32.
    • (2001) Urban Water , vol.3 , Issue.1 , pp. 25-32
    • Zabel, T.1    Milne, I.2    Mckay, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.