메뉴 건너뛰기




Volumn 7904, Issue , 2011, Pages

Effect of double-helix point-spread functions on 3D imaging in the presence of spherical aberrations

Author keywords

3D microscopy; Computational imaging; Double helix point spread functions; Fluorescence microscopy; Point spread function engineering; Spherical aberration

Indexed keywords

3-D MICROSCOPY; COMPUTATIONAL IMAGING; DOUBLE HELIX POINT SPREAD FUNCTIONS; POINT SPREAD FUNCTION ENGINEERING; SPHERICAL ABERRATIONS;

EID: 79955161753     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.874111     Document Type: Conference Paper
Times cited : (8)

References (16)
  • 2
    • 0037057775 scopus 로고    scopus 로고
    • New paradigm for imaging systems
    • Cathey., T., and Dowski., E., "New paradigm for imaging systems", Applied Optics. Vol. 41, 6080-6092 (2002). (Pubitemid 35263581)
    • (2002) Applied Optics , vol.41 , Issue.29 , pp. 6080-6092
    • Cathey, W.T.1    Dowski, E.R.2
  • 3
    • 0000412790 scopus 로고    scopus 로고
    • Method of obtaining optical sectioning by using structured light in a conventional microscope
    • Neil, M. A. A., Juskaitis, and Wilson, T., "Method of Obtaining Optical Sectioning by Using Structured Light in a Conventional Microscope, "Optics Letters. 22, 1905-1907 (1997). (Pubitemid 127598999)
    • (1997) Optics Letters , vol.22 , Issue.24 , pp. 1905-1907
    • Neil, M.A.A.1    Juskaitis, R.2    Wilson, T.3
  • 4
    • 0028460042 scopus 로고
    • Breaking the diffraction resolution limit by stimulated emission: Stimulatedemission- depletion fluorescence microscopy
    • Hell, S., and Wichmann, W., "Breaking the diffraction resolution limit by stimulated emission: stimulatedemission- depletion fluorescence microscopy, "Optics Letters. 19 (11), 780-782 (1994).
    • (1994) Optics Letters , vol.19 , Issue.11 , pp. 780-782
    • Hell, S.1    Wichmann, W.2
  • 5
    • 62649175269 scopus 로고    scopus 로고
    • Three-dimensional, single-molecule fluorescence imaging beyond the diffraction limit by using a double-helix point spread function
    • Pavani, S. R. P., Thompson, M. A., Biteen, J. S. et al., "Three-dimensional, single-molecule fluorescence imaging beyond the diffraction limit by using a double-helix point spread function, " Proceedings Of The National Academy Of Sciences Of The United States Of America, 106(9), 2995-2999 (2009).
    • (2009) Proceedings of the National Academy of Sciences of the United States of America , vol.106 , Issue.9 , pp. 2995-2999
    • Pavani, S.R.P.1    Thompson, M.A.2    Biteen, J.S.3
  • 6
    • 67650770314 scopus 로고    scopus 로고
    • Three-dimensional localization with nanometer accuracy using a detector-limited double-helix point spread function system
    • Pavani, S. R. P., Greengard, A., and Piestun, R., "Three-dimensional Localization with Nanometer Accuracy using a Detector-Limited Double-Helix Point Spread Function System, " Applied Physics Letters, 95(2), (2009).
    • (2009) Applied Physics Letters , vol.95 , Issue.2
    • Pavani, S.R.P.1    Greengard, A.2    Piestun, R.3
  • 7
    • 58149114919 scopus 로고    scopus 로고
    • Three dimensional tracking of fluorescent microparticles using a photon- limited double-helix response system
    • Pavani, S. R. P., and Piestun, R., "Three Dimensional Tracking of Fluorescent Microparticles using a Photon- Limited Double-Helix Response System, " Optics Express, 16(26), 22048-22057 (2008).
    • (2008) Optics Express , vol.16 , Issue.26 , pp. 22048-22057
    • Pavani, S.R.P.1    Piestun, R.2
  • 8
    • 79955166002 scopus 로고    scopus 로고
    • Broadband three-dimensional imaging using a double-helix point spread function
    • Quirin, S., Pavani, S. R. P., and Piestun, R., "Broadband Three-Dimensional Imaging Using a Double-Helix Point Spread Function, "OSA FiO. 31, 181-183 (2009).
    • (2009) OSA FiO. , vol.31 , pp. 181-183
    • Quirin, S.1    Pavani, S.R.P.2    Piestun, R.3
  • 9
    • 0026465785 scopus 로고
    • Experimental test of an analytical model of aberration in an oil-immersion objective lens used in 3-dimensional light-microscopy
    • Gibson, S. F., and Lanni, F., "Experimental Test Of An Analytical Model Of Aberration In An Oil-Immersion Objective Lens Used In 3-Dimensional Light-Microscopy, " Journal Of The Optical Society Of America AOptics Image Science And Vision, 9(1), 154-166 (1992).
    • (1992) Journal of the Optical Society of America AOptics Image Science and Vision , vol.9 , Issue.1 , pp. 154-166
    • Gibson, S.F.1    Lanni, F.2
  • 11
    • 4544308033 scopus 로고    scopus 로고
    • Depth-variant maximum-likelihood restoration for three-dimensional fluorescence microscopy
    • Preza, C., and Conchello, J. A., "Depth-Variant Maximum-Likelihood Restoration for Three-Dimensional Fluorescence Microscopy, " JOSA-A(21), 1593-1601 (2004).
    • (2004) JOSA-A , vol.21 , pp. 1593-1601
    • Preza, C.1    Conchello, J.A.2
  • 13
    • 0037304012 scopus 로고    scopus 로고
    • Focusing of light through a stratified medium: A practical approach for computing microscope point spread functions. Part I: Conventional microscopy
    • Haeberle, O., "Focusing of light through a stratified medium: a practical approach for computing microscope point spread functions. Part I: Conventional microscopy, " Optics Communications, 216(1-3), 55-63 (2003).
    • (2003) Optics Communications , vol.216 , Issue.1-3 , pp. 55-63
    • Haeberle, O.1
  • 14
    • 79955133369 scopus 로고    scopus 로고
    • 3D reconstruction of fluorescence microscopy image intensities using multiple depth variant point spread functions
    • Preza, C., and Myneni, V., "3D Reconstruction of Fluorescence Microscopy Image Intensities using Multiple Depth Variant Point Spread Functions, "BiOS. 7570-2, (2010).
    • (2010) BiOS , pp. 7570-7572
    • Preza, C.1    Myneni, V.2
  • 15
    • 0032186407 scopus 로고    scopus 로고
    • Superresolution and convergence properties of the expectation- maximization algorithm for maximum-likelihood deconvolution of incoherent images
    • Conchello, J. A., "Superresolution and convergence properties of the expectation-maximization algorithm for maximum-likelihood deconvolution of incoherent images., " Journal of Optical Society of America, 15(10), 2609-2619 (1998).
    • (1998) Journal of Optical Society of America , vol.15 , Issue.10 , pp. 2609-2619
    • Conchello, J.A.1
  • 16
    • 0025595687 scopus 로고
    • Why least squares and maximum entropy? An axiomatic approach to inference for linear inverse problems
    • Csiszar, I., "Why least squares and maximum entropy?An axiomatic approach to inference for linear inverse problems, " Annals of Statistics, 19, 2032-2066 (1991).
    • (1991) Annals of Statistics , vol.19 , pp. 2032-2066
    • Csiszar, I.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.