Volumn 92, Issue 5, 2011, Pages 408-413

Assessing the sensory function of the ocular surface: Implications of use of a non-contact air jet aesthesiometer versus the Cochet-Bonnet aesthesiometer

Author keywords

Cochet Bonnet aesthesiometer; Corneal mechanoceptor stimulation; Corneal sensitivity; CRCERT Belmonte aesthesiometer; Ocular surface sensitivity; Sensory function

Indexed keywords

ANESTHETIC EQUIPMENT; ARTICLE; CLINICAL ASSESSMENT; COCHET BONNET AESTHESIOMETER; COMPARATIVE STUDY; CORNEA SENSIBILITY; CRCERT BELMONTE AETHESIOMETER; FORCE; HUMAN; HUMAN EXPERIMENT; NERVE POTENTIAL; NERVE STIMULATION; NORMAL HUMAN; PRIORITY JOURNAL; SENSORY SYSTEM;

EID: 79955127211     PISSN: 00144835     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.exer.2011.02.016     Document Type: Article
Times cited : (103)

References (14)
  • 1
    • 0032894769 scopus 로고    scopus 로고
    • Measurement of corneal sensitivity to mechanical and chemical stimulation with a CO2 esthesiometer
    • Belmonte C., Acosta M.C., Schmelz M., Gallar J. Measurement of corneal sensitivity to mechanical and chemical stimulation with a CO2 esthesiometer. Invest. Ophthalmol. Vis. Sci. 1999, 40:513-519.
    • (1999) Invest. Ophthalmol. Vis. Sci. , vol.40 , pp. 513-519
    • Belmonte, C.1    Acosta, M.C.2    Schmelz, M.3    Gallar, J.4
  • 2
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1:307-311.
    • (1986) Lancet , vol.1 , pp. 307-311
    • Bland, J.M.1    Altman, D.G.2
  • 4
    • 0002739649 scopus 로고
    • L'Esthesie Corneenne. Sa mesure clinique. Ses variations physiologiques et pathologiques
    • Cochet P., Bonnet R. L'Esthesie Corneenne. Sa mesure clinique. Ses variations physiologiques et pathologiques. La Clinique Ophtalomologique 1960, 4:3-27.
    • (1960) La Clinique Ophtalomologique , vol.4 , pp. 3-27
    • Cochet, P.1    Bonnet, R.2
  • 6
    • 0027153118 scopus 로고
    • Investigation of limbal touch sensitivity by using a Cochet-Bonnet aesthesiometer
    • Lawrenson J.G., Ruskell G.L. Investigation of limbal touch sensitivity by using a Cochet-Bonnet aesthesiometer. Br. J. Ophthalmol. 1993, 77:339-343.
    • (1993) Br. J. Ophthalmol. , vol.77 , pp. 339-343
    • Lawrenson, J.G.1    Ruskell, G.L.2
  • 7
    • 0014335041 scopus 로고
    • Sensitivity threshold of the lower lid margin in the course of adaptation to contact lenses
    • Lowther G.E., Hill R.M. Sensitivity threshold of the lower lid margin in the course of adaptation to contact lenses. Am. J. Optom. Arch. Am. Acad. Optom. 1968, 587-594.
    • (1968) Am. J. Optom. Arch. Am. Acad. Optom. , pp. 587-594
    • Lowther, G.E.1    Hill, R.M.2
  • 8
    • 0027451882 scopus 로고
    • Structural and functional specialisation of Ad and C fibre free nerve endings innervating rabbit corneal epithelium
    • MacIver M.B., Tanelian D.L. Structural and functional specialisation of Ad and C fibre free nerve endings innervating rabbit corneal epithelium. J. Neurosci. 1993, 13:4511-4524.
    • (1993) J. Neurosci. , vol.13 , pp. 4511-4524
    • MacIver, M.B.1    Tanelian, D.L.2
  • 9
    • 0345646291 scopus 로고
    • Effect of bending of the nylon thread of the Cochet-Bonnet aesthesiometer upon the recorded pressure
    • 28
    • Millodot M., Larson W. Effect of bending of the nylon thread of the Cochet-Bonnet aesthesiometer upon the recorded pressure. Contact Lens 1967, 1:5-6. 28.
    • (1967) Contact Lens , vol.1 , pp. 5-6
    • Millodot, M.1    Larson, W.2
  • 10
    • 0031770403 scopus 로고    scopus 로고
    • Reliability of the non-contact corneal aesthesiometer and its comparison with the Cochet-Bonnet aesthesiometer
    • Murphy P.J., Lawrenson J.G., Patel S., Marshall J. Reliability of the non-contact corneal aesthesiometer and its comparison with the Cochet-Bonnet aesthesiometer. Ophthal. Physiol. Opt. 1998, 18:532-539.
    • (1998) Ophthal. Physiol. Opt. , vol.18 , pp. 532-539
    • Murphy, P.J.1    Lawrenson, J.G.2    Patel, S.3    Marshall, J.4
  • 11
    • 0032913957 scopus 로고    scopus 로고
    • Corneal surface temperature change as the mode of stimulation of the non-contact corneal aesthesiometer
    • Murphy P.J., Morgan P.B., Patel S., Marshall J. Corneal surface temperature change as the mode of stimulation of the non-contact corneal aesthesiometer. Cornea 1999, 18:333-342.
    • (1999) Cornea , vol.18 , pp. 333-342
    • Murphy, P.J.1    Morgan, P.B.2    Patel, S.3    Marshall, J.4
  • 13
    • 0015543062 scopus 로고
    • Conjunctival sensitivity in normal eyes
    • Norn M.S. Conjunctival sensitivity in normal eyes. Acta Ophthalmol. 1973, 51:58-66.
    • (1973) Acta Ophthalmol. , vol.51 , pp. 58-66
    • Norn, M.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.