메뉴 건너뛰기




Volumn 81, Issue 3, 2011, Pages 880-887

Analysis of prostate patient setup and tracking data: Potential intervention strategies

Author keywords

Intervention strategies; Intrafraction motion; Patient setup; Planning target volume; PTV margin; Tracking

Indexed keywords

INTERVENTION STRATEGY; INTRAFRACTION MOTION; PATIENT SETUP; PLANNING TARGET VOLUME; PTV MARGIN;

EID: 79955069088     PISSN: 03603016     EISSN: 1879355X     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2010.07.1978     Document Type: Article
Times cited : (27)

References (24)
  • 1
    • 23844553577 scopus 로고    scopus 로고
    • A review of prostate motion with considerations for the treatment of prostate cancer
    • DOI 10.1016/j.meddos.2005.03.005, PII S0958394705001007
    • T. Byrne A review of prostate motion with considerations for the treatment of prostate cancer Med Dosim 30 2005 155 161 (Pubitemid 41160455)
    • (2005) Medical Dosimetry , vol.30 , Issue.3 , pp. 155-161
    • Byrne, T.E.1
  • 4
    • 33847328730 scopus 로고    scopus 로고
    • Multi-institutional clinical experience with the Calypso system in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy
    • P.A. Kupelian, T.R. Willoughby, and A. Mahadevan Multi-institutional clinical experience with the Calypso system in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy Int J Radiat Oncol Biol Phys 67 2007 1088 1098
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 1088-1098
    • Kupelian, P.A.1    Willoughby, T.R.2    Mahadevan, A.3
  • 5
    • 42949150341 scopus 로고    scopus 로고
    • Dosimetric consequences of intrafraction prostate motion
    • H.S. Li, I. Chetty, and C.A. Enke Dosimetric consequences of intrafraction prostate motion Int J Radiat Oncol Biol Phys 71 2008 801 812
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , pp. 801-812
    • Li, H.S.1    Chetty, I.2    Enke, C.A.3
  • 6
    • 33645368752 scopus 로고    scopus 로고
    • Influence of intrafraction motion on margins for prostate radiotherapy
    • D.W. Litzenberg, J.M. Balter, and S.W. Hadley Influence of intrafraction motion on margins for prostate radiotherapy Int J Radiat Oncol Biol Phys 65 2006 548 553
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 548-553
    • Litzenberg, D.W.1    Balter, J.M.2    Hadley, S.W.3
  • 7
    • 33646487136 scopus 로고    scopus 로고
    • Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer
    • T.R. Willoughby, P.A. Kupelian, and J. Pouliot Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer Int J Radiat Oncol Biol Phys 65 2006 528 534
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 528-534
    • Willoughby, T.R.1    Kupelian, P.A.2    Pouliot, J.3
  • 10
    • 0034237797 scopus 로고    scopus 로고
    • The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy
    • DOI 10.1016/S0360-3016(00)00518-6, PII S0360301600005186
    • M. van Herk, P. Remeijer, and C. Rasch The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy Int J Radiat Oncol Biol Phys 47 2000 1121 1135 (Pubitemid 30345614)
    • (2000) International Journal of Radiation Oncology Biology Physics , vol.47 , Issue.4 , pp. 1121-1135
    • Van Herk, M.1    Remeijer, P.2    Rasch, C.3    Lebesque, J.V.4
  • 12
    • 51849161363 scopus 로고    scopus 로고
    • Efficient use of continuous, real-time prostate localization
    • K.T. Malinowski, C. Noel, and M. Roy Efficient use of continuous, real-time prostate localization Phys Med Biol 53 2008 4959 4970
    • (2008) Phys Med Biol , vol.53 , pp. 4959-4970
    • Malinowski, K.T.1    Noel, C.2    Roy, M.3
  • 18
    • 25844451193 scopus 로고    scopus 로고
    • Prostate position relative to pelvic bony anatomy based on intraprostatic gold markers and electronic portal imaging
    • DOI 10.1016/j.ijrobp.2005.02.022, PII S0360301605003603
    • J.M. Schallenkamp, M.G. Herman, and J.J. Kruse Prostate position relative to pelvic bony anatomy based on intraprostatic gold markers and electronic portal imaging Int J Radiat Oncol Biol Phys 63 2005 800 811 (Pubitemid 41400069)
    • (2005) International Journal of Radiation Oncology Biology Physics , vol.63 , Issue.3 , pp. 800-811
    • Schallenkamp, J.M.1    Herman, M.G.2    Kruse, J.J.3    Pisansky, T.M.4
  • 19
    • 33646182382 scopus 로고    scopus 로고
    • Clinical application of a repositioning scheme, using gold markers and electronic portal imaging
    • F. van den Heuvel, J. Fugazzi, and E. Seppi Clinical application of a repositioning scheme, using gold markers and electronic portal imaging Radiother Oncol 79 2006 94 100
    • (2006) Radiother Oncol , vol.79 , pp. 94-100
    • Van Den Heuvel, F.1    Fugazzi, J.2    Seppi, E.3
  • 23
    • 45449088673 scopus 로고    scopus 로고
    • Observations on real-time prostate gland motion using electromagnetic tracking
    • K.M. Langen, T.R. Willoughby, and S.L. Meeks Observations on real-time prostate gland motion using electromagnetic tracking Int J Radiat Oncol Biol Phys 71 2008 1084 1090
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , pp. 1084-1090
    • Langen, K.M.1    Willoughby, T.R.2    Meeks, S.L.3
  • 24
    • 50449083967 scopus 로고    scopus 로고
    • Simulated real time image guided intrafraction tracking-delivery for hypofractionated prostate IMRT
    • S. Hossain, P. Xia, and C. Chuang Simulated real time image guided intrafraction tracking-delivery for hypofractionated prostate IMRT Med Phys 35 2008 4041 4048
    • (2008) Med Phys , vol.35 , pp. 4041-4048
    • Hossain, S.1    Xia, P.2    Chuang, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.