Volumn 14, Issue 3, 2011, Pages 389-406

Comparison of oscillation damping capability in three power control strategies for PMSG-based WECS

Author keywords

active damping; permanent magnetic synchronous generator (PMSG); power control; torsional vibration; wind energy conversion system (WECS)

Indexed keywords

DAMPING; ELECTRIC POWER SYSTEM CONTROL; ENERGY CONVERSION; PERMANENT MAGNETS; POWER CONTROL; SYNCHRONOUS GENERATORS; VIBRATIONS (MECHANICAL); VOLTAGE CONTROL; WIND POWER;

EID: 79955050936     PISSN: 10954244     EISSN: 10991824     Source Type: Journal    
DOI: 10.1002/we.428     Document Type: Article
Times cited : (37)

References (31)
  • 3
    • 33244483622 scopus 로고    scopus 로고
    • Control of permanent-magnet generators applied to variable-speed wind-energy systems connected to the grid
    • DOI 10.1109/TEC.2005.853735
    • Chinchilla M, Arnaltes S, Burgos J., Control of permanent-magnet generators applied to variable-speed wind-energy systems connected to the grid. IEEE Transactions on Energy Conversion 2006; 21: 130-135. DOI:10.1109/TEC.2005. 853735. (Pubitemid 43280527)
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.1 , pp. 130-135
    • Chinchilla, M.1    Arnaltes, S.2    Burgos, J.C.3
  • 4
    • 29244445870 scopus 로고    scopus 로고
    • PM wind generator topologies
    • DOI 10.1109/TIA.2005.858261
    • Chen Y, Pillay P, Khan A., PM wind generator topologies. IEEE Transactions on Industry Applications 2005; 41: 1619-1626. DOI:10.1109/TIA.2005. 858261. (Pubitemid 41824653)
    • (2005) IEEE Transactions on Industry Applications , vol.41 , Issue.6 , pp. 1619-1626
    • Chen, Y.1    Pillay, P.2    Khan, A.3
  • 6
    • 55349113607 scopus 로고    scopus 로고
    • Modelling and control of variable-speed multi-pole permanent magnet synchronous generator wind turbine
    • DOI:10.1002/we.278.
    • Hansen AD, Michalke G., Modelling and control of variable-speed multi-pole permanent magnet synchronous generator wind turbine. Wind Energy 2008; 11: 537-554. DOI:10.1002/we.278.
    • (2008) Wind Energy , vol.11 , pp. 537-554
    • Hansen, A.D.1    Michalke, G.2
  • 7
    • 33846707953 scopus 로고    scopus 로고
    • Co-ordinated voltage control of DFIG wind turbines in uninterrupted operation during grid faults
    • DOI 10.1002/we.207
    • Hansen A, Michalke G, Sørensen P, Lund T, Iov F., Co-ordinated voltage control of dfig wind turbines in uninterrupted operation during grid faults. Wind Energy 2007; 10: 51-68. DOI:10.1002/we.207. (Pubitemid 46192107)
    • (2007) Wind Energy , vol.10 , Issue.1 , pp. 51-68
    • Hansen, A.D.1    Michalke, G.2    Sorensen, P.3    Lund, T.4    Iov, F.5
  • 10
    • 43849097550 scopus 로고    scopus 로고
    • Frequency response capability of full converter wind turbine generators in comparison to conventional generation
    • DOI 10.1109/TPWRS.2008.920197
    • Conroy J, Watson R., Frequency response capability of full converter wind turbine generators in comparison to conventional generation. IEEE Transactions on Power Systems 2008; 23: 649-656. DOI:10.1109/TPWRS.2008.920197. (Pubitemid 351695844)
    • (2008) IEEE Transactions on Power Systems , vol.23 , Issue.2 , pp. 649-656
    • Conroy, J.F.1    Watson, R.2
  • 11
    • 34250757748 scopus 로고    scopus 로고
    • A review of power converter topologies for wind generators
    • DOI 10.1016/j.renene.2006.12.002, PII S0960148106003430
    • Baroudia JA, Dinavahi V, Knighta AM., A review of power converter topologies for wind generators. Renewable Energy 2007; 32: 2369-2385. DOI:10.1016/j.renene.2006.12.002. (Pubitemid 46962977)
    • (2007) Renewable Energy , vol.32 , Issue.14 , pp. 2369-2385
    • Baroudi, J.A.1    Dinavahi, V.2    Knight, A.M.3
  • 12
    • 0032593021 scopus 로고    scopus 로고
    • Performance optimization for doubly fed wind power generation systems
    • DOI:10.1109/28.777205.
    • Bhowmik S, Spee R, Enslin J., Performance optimization for doubly fed wind power generation systems. IEEE Transactions on Industry Applications 1999; 35: 949-958. DOI:10.1109/28.777205.
    • (1999) IEEE Transactions on Industry Applications , vol.35 , pp. 949-958
    • Bhowmik, S.1    Spee, R.2    Enslin, J.3
  • 13
    • 69449085926 scopus 로고    scopus 로고
    • A review of the state of the art of power electronics for wind turbines
    • DOI:10.1109/TPEL.2009.2017082.
    • Chen Z, Guerrero JM, Blaabjerg F., A review of the state of the art of power electronics for wind turbines. IEEE Transactions on Power Electronics 2009; 24: 1859-1875. DOI:10.1109/TPEL.2009.2017082.
    • (2009) IEEE Transactions on Power Electronics , vol.24 , pp. 1859-1875
    • Chen, Z.1    Guerrero, J.M.2    Blaabjerg, F.3
  • 14
    • 34249780371 scopus 로고    scopus 로고
    • Control methodology to mitigate the grid impact of wind turbines
    • DOI 10.1109/TEC.2006.878242
    • Rawn B, Lehn P, Maggiore M., Control methodology to mitigate the grid impact of wind turbines. IEEE Transactions on Energy Conversion 2007; 22: 431-438. DOI:10.1109/TEC.2006.878242. (Pubitemid 46845643)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.2 , pp. 431-438
    • Rawn, B.G.1    Lehn, P.W.2    Maggiore, M.3
  • 15
    • 30944433591 scopus 로고    scopus 로고
    • Centralised power control of wind farm with doubly fed induction generators
    • DOI:10.1016/j.renene.2005.05.011.
    • Hansen A, Sørensen P, Iov F, Blaabjerg F., Centralised power control of wind farm with doubly fed induction generators. Renew. Energy 2006; 31: 949-958. DOI:10.1016/j.renene.2005.05.011.
    • (2006) Renew. Energy , vol.31 , pp. 949-958
    • Hansen, A.1    Sørensen, P.2    Iov, F.3    Blaabjerg, F.4
  • 16
    • 20444427743 scopus 로고    scopus 로고
    • E.ON Netz GmbH E.ON Netz GmbH,. Tech. Rep. [Online]. Available:. (Accessed September 13, 2010)
    • E.ON Netz GmbH. Grid code-high and extra high voltage. E.ON Netz GmbH, 2006. Tech. Rep. [Online]. Available:. (Accessed September 13, 2010)
    • (2006) Grid Code-high and Extra High Voltage
  • 17
    • 47249119281 scopus 로고    scopus 로고
    • Test bench for grid code simulations for multi-mw wind turbines, design and control
    • DOI:10.1109/TPEL.2008.925425.
    • Saniter C, Janning J., Test bench for grid code simulations for multi-mw wind turbines, design and control. IEEE Transactions on Power Electronics 2008; 23: 1707-1715. DOI:10.1109/TPEL.2008.925425.
    • (2008) IEEE Transactions on Power Electronics , vol.23 , pp. 1707-1715
    • Saniter, C.1    Janning, J.2
  • 18
    • 36348950411 scopus 로고    scopus 로고
    • Voltage and transient stability support by wind farms complying with the E.ON netz grid code
    • DOI 10.1109/TPWRS.2007.907523
    • Ullah N, Thiringer T, Karlsson D., Voltage and transient stability support by wind farms complying with the e.on netz grid code. IEEE Transactions on Power Systems 2007; 22: 1647-1656. DOI:10.1109/TPWRS.2007.907523. (Pubitemid 350141963)
    • (2007) IEEE Transactions on Power Systems , vol.22 , Issue.4 , pp. 1647-1656
    • Ullah, N.R.1    Thiringer, T.2    Karlsson, D.3
  • 21
    • 34249775795 scopus 로고    scopus 로고
    • Strategies to smooth wind power fluctuations of wind turbine generator
    • DOI 10.1109/TEC.2007.895401
    • Luo CL, Banakar H, Shen B, Ooi BT., Strategies to smooth wind power fluctuations of wind turbine generator. IEEE Transactions on Energy Conversion 2007; 22: 341-349. DOI:10.1109/TEC.2007.895401. (Pubitemid 46845632)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.2 , pp. 341-349
    • Luo, C.1    Banakar, H.2    Shen, B.3    Ooi, B.-T.4
  • 23
    • 34748851435 scopus 로고    scopus 로고
    • Comparative study on transient stability analysis of wind turbine generator system using different drive train models
    • DOI 10.1049/iet-rpg:20060030
    • Muyeen S, Ali M, Takahashi R, Murata T, Tamura J, Tomaki Y, Sakahara A, Sasano E., Comparative study on transient stability analysis of wind turbine generator system using different drive train models. IET Renewable Power Generation 2007; 1: 131-141. DOI:10.1049/iet-rpg:20060030. (Pubitemid 47472104)
    • (2007) IET Renewable Power Generation , vol.1 , Issue.2 , pp. 131-141
    • Muyeen, S.M.1    Hasan Ali, Md.2    Takahashi, R.3    Murata, T.4    Tamura, J.5    Tomaki, Y.6    Sakahara, A.7    Sasano, E.8
  • 24
    • 2942569637 scopus 로고    scopus 로고
    • Optimum control strategies in energy conversion of pmsg wind turbine system without mechanical sensors
    • DOI:10.1109/TEC.2004.827038.
    • Tan K, Islam S., Optimum control strategies in energy conversion of pmsg wind turbine system without mechanical sensors. IEEE Transactions on Energy Conversion 2004; 19: 392-399. DOI:10.1109/TEC.2004.827038.
    • (2004) IEEE Transactions on Energy Conversion , vol.19 , pp. 392-399
    • Tan, K.1    Islam, S.2
  • 25
    • 1542285787 scopus 로고    scopus 로고
    • Sensorless vector control of induction machines for variablespeed wind energy applications
    • DOI:10.1109/TEC.2003.821863.
    • Cardenas R, Pena R., Sensorless vector control of induction machines for variablespeed wind energy applications. IEEE Transactions on Energy Conversion 2004; 19: 196-205. DOI:10.1109/TEC.2003.821863.
    • (2004) IEEE Transactions on Energy Conversion , vol.19 , pp. 196-205
    • Cardenas, R.1    Pena, R.2
  • 27
    • 0004178386 scopus 로고    scopus 로고
    • (3rd edn). Prentice-Hall: New Jersey,.
    • Khalil HK., Nonlinear Systems (3rd edn). Prentice-Hall: New Jersey, 2002. 505-520.
    • (2002) Nonlinear Systems , pp. 505-520
    • Khalil, H.K.1
  • 28
    • 61649120073 scopus 로고    scopus 로고
    • Optimization of multibrid permanent-magnet wind generator systems
    • DOI:10.1109/TEC.2008.2005279.
    • Li H, Chen Z, Polinder H., Optimization of multibrid permanent-magnet wind generator systems. IEEE Transactions on Energy Conversion 2009; 24: 82-92. DOI:10.1109/TEC.2008.2005279.
    • (2009) IEEE Transactions on Energy Conversion , vol.24 , pp. 82-92
    • Li, H.1    Chen, Z.2    Polinder, H.3
  • 29
    • 40449134843 scopus 로고    scopus 로고
    • Overview of different wind generator systems and their comparisons
    • DOI 10.1049/iet-rpg:20070044
    • Li H, Chen Z., Overview of different wind generator systems and their comparisons. IET Renewable Power Generation 2008; 2: 123-138. DOI:10.1049/iet-rpg:20070044. (Pubitemid 351347461)
    • (2008) IET Renewable Power Generation , vol.2 , Issue.2 , pp. 123-138
    • Li, H.1    Chen, Z.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.