메뉴 건너뛰기




Volumn 41, Issue 5, 2011, Pages 285-291

Automated detection of the osseous acetabular rim using three-dimensional models of the pelvis

Author keywords

3D model; Acetabular rim; Automated detection; Hip joint; Surgical navigation

Indexed keywords

3D MODELS; ACETABULAR RIM; AUTOMATED DETECTION; HIP JOINTS; SURGICAL NAVIGATION;

EID: 79955043494     PISSN: 00104825     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.compbiomed.2011.03.004     Document Type: Article
Times cited : (32)

References (22)
  • 4
    • 0037318090 scopus 로고    scopus 로고
    • Anterior femoro-acetabular impingement due to acetabular retroversion. Treatment with periacetabular osteotomy
    • Siebenrock K.A., Schoeniger R., Ganz R. Anterior femoro-acetabular impingement due to acetabular retroversion. Treatment with periacetabular osteotomy. J. Bone Joint Surg. Am. 2003, 85-A(2):278-286.
    • (2003) J. Bone Joint Surg. Am. , Issue.2 , pp. 278-286
    • Siebenrock, K.A.1    Schoeniger, R.2    Ganz, R.3
  • 5
    • 60149089706 scopus 로고    scopus 로고
    • Femoroacetabular impingement: radiographic diagnosis what the radiologist should know
    • Tannast M., Siebenrock K.A., Anderson S.E. Femoroacetabular impingement: radiographic diagnosis what the radiologist should know. Radiologia. 2008, 50(4):271-284.
    • (2008) Radiologia. , vol.50 , Issue.4 , pp. 271-284
    • Tannast, M.1    Siebenrock, K.A.2    Anderson, S.E.3
  • 6
    • 77951367444 scopus 로고
    • A new method for determination of the angle of the pevic acetabulum in child and in adult
    • Idelberger K., Frank A. A new method for determination of the angle of the pevic acetabulum in child and in adult. Z. Orthop. Ihre. Grenzgeb. 1952, 82(4):571-577.
    • (1952) Z. Orthop. Ihre. Grenzgeb. , vol.82 , Issue.4 , pp. 571-577
    • Idelberger, K.1    Frank, A.2
  • 7
    • 73049147939 scopus 로고
    • False profile of the pelvis. A new radiographic incidence for the study of the hip. Its use in dysplasias and different coxopathies
    • Lequesne M., de S. False profile of the pelvis. A new radiographic incidence for the study of the hip. Its use in dysplasias and different coxopathies. Rev. Rhum. Mal. Osteoartic. 1961, 28:643-652.
    • (1961) Rev. Rhum. Mal. Osteoartic. , vol.28 , pp. 643-652
    • Lequesne, M.1    de, S.2
  • 8
    • 0013145471 scopus 로고
    • General radiography of the hip joint
    • Springer, Berlin, Heidelbert, D. Toennis (Ed.)
    • Toennis D. General radiography of the hip joint. Congenital Dysplasia and Dislocation of the Hip 1987, 100-142. Springer, Berlin, Heidelbert. D. Toennis (Ed.).
    • (1987) Congenital Dysplasia and Dislocation of the Hip , pp. 100-142
    • Toennis, D.1
  • 9
    • 14044267579 scopus 로고    scopus 로고
    • Navigating and visualizing three-dimensional data sets
    • Spec No. 2
    • John N.W., McCloy R.F. Navigating and visualizing three-dimensional data sets. Br. J. Radiol. 2004, 77(2):S108-S113. Spec No. 2.
    • (2004) Br. J. Radiol. , vol.77 , Issue.2
    • John, N.W.1    McCloy, R.F.2
  • 14
    • 44949208280 scopus 로고    scopus 로고
    • MARVIN: a medical research application framework based on open source software
    • Rudolph T., Puls M. MARVIN: a medical research application framework based on open source software. Comput. Meth. Programs Biomed. 2008, 91:165-174.
    • (2008) Comput. Meth. Programs Biomed. , vol.91 , pp. 165-174
    • Rudolph, T.1    Puls, M.2
  • 15
    • 0035197536 scopus 로고    scopus 로고
    • Restricted surface matching-numerical optimization and technical evaluation
    • Bachler R., Bunke H., Nolte L.P. Restricted surface matching-numerical optimization and technical evaluation. Comput. Aided Surg. 2001, 6(3):143-152.
    • (2001) Comput. Aided Surg. , vol.6 , Issue.3 , pp. 143-152
    • Bachler, R.1    Bunke, H.2    Nolte, L.P.3
  • 16
    • 85044699569 scopus 로고    scopus 로고
    • Inter-rater agreement in the scoring of abstracts submitted to a primary care research conference
    • Montgomery A.A., Graham A., Evans P.H., Fahey T. Inter-rater agreement in the scoring of abstracts submitted to a primary care research conference. BMC Health Serv. Res. 2002, 2(1):8.
    • (2002) BMC Health Serv. Res. , vol.2 , Issue.1 , pp. 8
    • Montgomery, A.A.1    Graham, A.2    Evans, P.H.3    Fahey, T.4
  • 17
    • 0035187669 scopus 로고    scopus 로고
    • Atlas-based segmentation of bone structures to support the virtual planning of hip operations
    • Ehrhardt J., Handels H., Malina T., Strathmann B., Plotz W., Poppl S.J. Atlas-based segmentation of bone structures to support the virtual planning of hip operations. Int. J. Med. Inf. 2001, 64(2-3):439-447.
    • (2001) Int. J. Med. Inf. , vol.64 , Issue.2-3 , pp. 439-447
    • Ehrhardt, J.1    Handels, H.2    Malina, T.3    Strathmann, B.4    Plotz, W.5    Poppl, S.J.6
  • 18
    • 70349367045 scopus 로고    scopus 로고
    • 3D Shape reasoning for identifying anatomical landmarks
    • Subburaj K., Ravi B., Agarval M.G. 3D Shape reasoning for identifying anatomical landmarks. Comput.-Aided Des. Appl. 2008, (5):153-160.
    • (2008) Comput.-Aided Des. Appl. , Issue.5 , pp. 153-160
    • Subburaj, K.1    Ravi, B.2    Agarval, M.G.3
  • 19
    • 45249100231 scopus 로고    scopus 로고
    • Acetabular rim and surface segmentation for hip surgery planning and dysplasia evaluation
    • Tan S., Yao J., Yao L., Summers R.M., Ward M.M. Acetabular rim and surface segmentation for hip surgery planning and dysplasia evaluation. Proc. SPIE 2008.
    • (2008) Proc. SPIE
    • Tan, S.1    Yao, J.2    Yao, L.3    Summers, R.M.4    Ward, M.M.5
  • 20
    • 79955000595 scopus 로고    scopus 로고
    • Diagnosis of femoro-acetabular impingement based on the equidistant hip joint simulation strategy, in: B.L. Davies, L. Joskowicz, S. Murphy, Proceedings of the 9th Annual Meeting of CAOS-International
    • T.M. Ecker, M. Puls, M. Tannast, S.D. Steppacher, S. Weber, K. Siebenrock, J.H. Kowal, Diagnosis of femoro-acetabular impingement based on the equidistant hip joint simulation strategy, in: B.L. Davies, L. Joskowicz, S. Murphy, Proceedings of the 9th Annual Meeting of CAOS-International, 2009.
    • (2009)
    • Ecker, T.M.1    Puls, M.2    Tannast, M.3    Steppacher, S.D.4    Weber, S.5    Siebenrock, K.6    Kowal, J.H.7
  • 21
    • 79955004850 scopus 로고    scopus 로고
    • Accuracy and reliability of computer-assisted osteochondroplasty of the femoral head-neck junction, in: B.L. Davies, L. Joskowicz, S. Murphy, 9th Annual Meeting of CAOS-International, Boston, MA, USA.
    • M. Puls, T.M. Ecker, S.D. Steppacher, K. Siebenrock, J.H. Kowal, M. Tannast, Accuracy and reliability of computer-assisted osteochondroplasty of the femoral head-neck junction, in: B.L. Davies, L. Joskowicz, S. Murphy, 9th Annual Meeting of CAOS-International, 2009, Boston, MA, USA.
    • (2009)
    • Puls, M.1    Ecker, T.M.2    Steppacher, S.D.3    Siebenrock, K.4    Kowal, J.H.5    Tannast, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.