메뉴 건너뛰기




Volumn 135, Issue 5, 2011, Pages 732-740

Evaluation of European Concerted Action on Anticoagulation lyophilized plasmas for INR derivation using the PT/INR Line

Author keywords

Coagulometers; ECAA plasmas; INR correction; International normalized ratio; Prothrombin time; PT INR Line; Thromboplastin

Indexed keywords

THROMBOPLASTIN;

EID: 79955040507     PISSN: 00029173     EISSN: 19437722     Source Type: Journal    
DOI: 10.1309/AJCPEKRPL4K8TZMF     Document Type: Article
Times cited : (9)

References (14)
  • 1
    • 77957745242 scopus 로고    scopus 로고
    • Simplified method for international normalized ratio (INR) derivation based on the prothrombin time/INR Line: An international study
    • Poller L, Ibrahim S, Keown M, et al. Simplified method for international normalized ratio (INR) derivation based on the prothrombin time/INR Line: an international study. Clin Chem. 2010;56:1608-1617.
    • (2010) Clin. Chem. , vol.56 , pp. 1608-1617
    • Poller, L.1    Ibrahim, S.2    Keown, M.3
  • 2
    • 78650939334 scopus 로고    scopus 로고
    • The prothrombin time/international normalized ratio (PT/INR) Line: Derivation of local INR with commercial thromboplastins and coagulometers: Two independent studies
    • the European Action on Anticoagulation, published online ahead of print January 7, 2011, doi: 10.1111/j.1538-7836.2010.04109.x
    • Poller L, Ibrahim S, Keown M, et al; and the European Action on Anticoagulation. The prothrombin time/international normalized ratio (PT/INR) Line: derivation of local INR with commercial thromboplastins and coagulometers: two independent studies [published online ahead of print January 7, 2011]. J Thromb Haemost. 2011;9:140-148. doi: 10.1111/j.1538-7836.2010.04109.x.
    • (2011) J. Thromb. Haemost. , vol.9 , pp. 140-148
    • Poller, L.1    Ibrahim, S.2    Keown, M.3
  • 3
    • 0013559777 scopus 로고
    • WHO Expert Committee on Biological Standardisation. 33rd Report
    • WHO Expert Committee on Biological Standardisation. 33rd Report, WHO Technical Series. 1983;687:81-105.
    • (1983) WHO Technical Series , vol.687 , pp. 81-105
  • 4
    • 0030971058 scopus 로고    scopus 로고
    • Long-term french experience in INR standardization by a procedure using plasma calibrants
    • Houbouyan LL, Goguel AF. Long-term French experience in INR standardization by a procedure using plasma calibrants. Am J Clin Pathol. 1997;108:83-89. (Pubitemid 27276517)
    • (1997) American Journal of Clinical Pathology , vol.108 , Issue.1 , pp. 83-89
    • Houbouyan, L.L.1    Goguel, A.F.2
  • 6
    • 79954995990 scopus 로고    scopus 로고
    • Wayne, PA: Clinical and Laboratory Standards Institute. Procedures for Validation of INR and Local Calibration of PT/INR Systems; Approved guideline
    • Clinical and Laboratory Standards Institute. Procedures for Validation of INR and Local Calibration of PT/INR Systems; Approved guideline. Wayne, PA: Clinical and Laboratory Standards Institute; 2005. Volume 25; No. 23.
    • (2005) Clinical and Laboratory Standards Institute , vol.25 , Issue.23
  • 9
    • 52649142040 scopus 로고    scopus 로고
    • A multicentre randomised clinical endpoint study of PARMA 5 computer-assisted oral anticoagulant dosage
    • Poller L, Keown M, Ibrahim S, et al. A multicentre randomised clinical endpoint study of PARMA 5 computer-assisted oral anticoagulant dosage. Br J Haematol. 2008;143:274-283.
    • (2008) Br. J. Haematol. , vol.143 , pp. 274-283
    • Poller, L.1    Keown, M.2    Ibrahim, S.3
  • 10
    • 62549128661 scopus 로고    scopus 로고
    • A multicentre randomised assessment of the DAWN AC computer-assisted oral anticoagulant dosage program
    • Poller L, Keown M, Ibrahim S, et al. A multicentre randomised assessment of the DAWN AC computer-assisted oral anticoagulant dosage program. Thromb Haemost. 2009;101:487-494.
    • (2009) Thromb. Haemost. , vol.101 , pp. 487-494
    • Poller, L.1    Keown, M.2    Ibrahim, S.3
  • 11
    • 79954993557 scopus 로고    scopus 로고
    • FDA class II device 9611195, Sets of 20 lyophilised plasma calibrants to provide prothrombin system ISI. Food and Drug Administration, FDA 510 k K991439
    • FDA class II device 9611195. Poller Calibrants. Sets of 20 lyophilised plasma calibrants to provide prothrombin system ISI. Food and Drug Administration. 1999. FDA 510 (k) K991439.
    • (1999) Poller Calibrants
  • 12
    • 0031756878 scopus 로고    scopus 로고
    • The European Concerted Action on Anticoagulation (ECAA): Field studies of coagulometer effects on the ISI of ECAA thromboplastins
    • Poller L, van den Besselaar AMHP, Jespersen J, et al. The European Concerted Action on Anticoagulation (ECAA): field studies of coagulometer effects on the ISI of ECAA thromboplastins. Thromb Haemost. 1998;80:615-623. (Pubitemid 28479350)
    • (1998) Thrombosis and Haemostasis , vol.80 , Issue.4 , pp. 615-623
    • Poller, L.1    Van Den Besselaar, A.M.H.P.2    Jespersen, J.3    Tripodi, A.4    Houghton, D.5
  • 13
    • 0031867279 scopus 로고    scopus 로고
    • 09-The importance of "like-to-like" ISI calibrations with freeze-dried plasmas: European Concerted Action on Anticoagulation
    • Poller L, van den Besselaar AMHP, Jespersen J, et al. 09-The importance of "like-to-like" ISI calibrations with freeze-dried plasmas: European Concerted Action on Anticoagulation. J Clin Pathol. 1998;51:275-279.
    • (1998) J. Clin. Pathol. , vol.51 , pp. 275-279
    • Poller, L.1    Van Den Besselaar, A.H.M.P.2    Jespersen, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.