Volumn 35, Issue 4, 2011, Pages 392-397

A New Way to Reduce Flow Disturbance in Endovascular Stents: A Numerical Study

Author keywords

Computational fluid dynamics; Endovascular stent; Oscillating shear index; Restenosis; Streamlined cross section; Wall shear stress

Indexed keywords

COMPUTATIONAL FLUID DYNAMICS; FLOW PATTERNS; OSCILLATING FLOW; SHEAR FLOW; SHEAR STRESS; STENTS; STRUCTURAL DESIGN; WIRE;

EID: 79955018825     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2010.01106.x     Document Type: Article
Times cited : (21)

References (31)
  • 1
    • 0037659160 scopus 로고    scopus 로고
    • Experimental study of laminar blood flow through an artery treated by a stent implantation: characterisation of intra-stent wall shear stress
    • Benard N, Coisne D, Donal E, Perrault R. Experimental study of laminar blood flow through an artery treated by a stent implantation: characterisation of intra-stent wall shear stress. J Biomech 2003;36:991-8.
    • (2003) J Biomech , vol.36 , pp. 991-998
    • Benard, N.1    Coisne, D.2    Donal, E.3    Perrault, R.4
  • 2
    • 3042567527 scopus 로고    scopus 로고
    • Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal artery
    • LaDisa JF, Olson LE, Guler I, etal. Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal artery. J Appl Physiol 2004;97:424-30.
    • (2004) J Appl Physiol , vol.97 , pp. 424-430
    • LaDisa, J.F.1    Olson, L.E.2    Guler, I.3
  • 3
    • 0141765805 scopus 로고    scopus 로고
    • Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery
    • Moses JW, Leon MB, Popma JJ, etal. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003;349:1315-23.
    • (2003) N Engl J Med , vol.349 , pp. 1315-1323
    • Moses, J.W.1    Leon, M.B.2    Popma, J.J.3
  • 4
    • 23644444112 scopus 로고    scopus 로고
    • Blood flow in stented arteries: a parametric comparison of strut design patterns in three dimensions
    • He Y, Duraiswamy N, Frank AO, Moore JE Jr. Blood flow in stented arteries: a parametric comparison of strut design patterns in three dimensions. J Biomech Eng 2005;127:637-47.
    • (2005) J Biomech Eng , vol.127 , pp. 637-647
    • He, Y.1    Duraiswamy, N.2    Frank, A.O.3    Moore Jr, J.E.4
  • 5
    • 34548042953 scopus 로고    scopus 로고
    • Still a future for the bare metal stent
    • Barlis P, Di Mario C. Still a future for the bare metal stent. Int J Cardiol 2007;121:1-3.
    • (2007) Int J Cardiol , vol.121 , pp. 1-3
    • Barlis, P.1    Di Mario, C.2
  • 6
    • 0037062767 scopus 로고    scopus 로고
    • Focal in-stent restenosis near step-up: roles of low and oscillating shear stress
    • Thury A, Wentzel JJ, Vinke RV, etal. Focal in-stent restenosis near step-up: roles of low and oscillating shear stress. Circulation 2002;105:e185-7.
    • (2002) Circulation , vol.105
    • Thury, A.1    Wentzel, J.J.2    Vinke, R.V.3
  • 7
    • 14144250735 scopus 로고    scopus 로고
    • Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models
    • LaDisa JF Jr, Olson LE, Guler I, etal. Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models. J Appl Physiol 2005;98:947-57.
    • (2005) J Appl Physiol , vol.98 , pp. 947-957
    • LaDisa Jr, J.F.1    Olson, L.E.2    Guler, I.3
  • 8
    • 18244381253 scopus 로고    scopus 로고
    • Computational study of fluid mechanical disturbance induced by endovascular stents
    • Seo T, Schachter LG, Barakat AI. Computational study of fluid mechanical disturbance induced by endovascular stents. Ann Biomed Eng 2005;33:444-56.
    • (2005) Ann Biomed Eng , vol.33 , pp. 444-456
    • Seo, T.1    Schachter, L.G.2    Barakat, A.I.3
  • 10
    • 0035178080 scopus 로고    scopus 로고
    • Restenosis after coronary placement of various stent types
    • Kastrati AJ, Mehilli J, Dirschinger J, etal. Restenosis after coronary placement of various stent types. Am J Cardiol 2001;87:34-9.
    • (2001) Am J Cardiol , vol.87 , pp. 34-39
    • Kastrati, A.J.1    Mehilli, J.2    Dirschinger, J.3
  • 12
    • 0029004856 scopus 로고
    • Endovascular stent design dictates experimental restenosis and thrombosis
    • Rogers C, Edelman ER. Endovascular stent design dictates experimental restenosis and thrombosis. Circulation 1995;91:2995-3001.
    • (1995) Circulation , vol.91 , pp. 2995-3001
    • Rogers, C.1    Edelman, E.R.2
  • 13
    • 2442493094 scopus 로고    scopus 로고
    • The influence of physical stent parameters upon restenosis
    • Morton AC, Crossman D, Gunn J. The influence of physical stent parameters upon restenosis. Pathol Biol 2004;52:196-205.
    • (2004) Pathol Biol , vol.52 , pp. 196-205
    • Morton, A.C.1    Crossman, D.2    Gunn, J.3
  • 16
    • 62849125838 scopus 로고    scopus 로고
    • Assessment of tissue prolapse after balloon-expandable stenting. Influence of stent cell geometry
    • Capelli C, Gervaso F, Petrini L, Dubini G, Migliavacca F. Assessment of tissue prolapse after balloon-expandable stenting. Influence of stent cell geometry. Med Eng Phys 2009;31:441-7.
    • (2009) Med Eng Phys , vol.31 , pp. 441-447
    • Capelli, C.1    Gervaso, F.2    Petrini, L.3    Dubini, G.4    Migliavacca, F.5
  • 17
    • 0025247921 scopus 로고
    • Flow patterns and spatial distribution of atherosclerotic lesions in human coronary arteries
    • Asakura T, Karino T. Flow patterns and spatial distribution of atherosclerotic lesions in human coronary arteries. Circ Res 1990;66:1045-66.
    • (1990) Circ Res , vol.66 , pp. 1045-1066
    • Asakura, T.1    Karino, T.2
  • 19
    • 0027691227 scopus 로고
    • The role of fluid mechanics in the localization and detection of atherosclerosis
    • Giddens DP, Zarins CK, Glagov S. The role of fluid mechanics in the localization and detection of atherosclerosis. J Biomech Eng 1993;115:588-94.
    • (1993) J Biomech Eng , vol.115 , pp. 588-594
    • Giddens, D.P.1    Zarins, C.K.2    Glagov, S.3
  • 20
    • 0027897784 scopus 로고
    • Spatial and temporal variations of wall shear stress within an end-to-side arterial anastomosis model
    • Ojha M. Spatial and temporal variations of wall shear stress within an end-to-side arterial anastomosis model. J Biomech 1993;26:1377-88.
    • (1993) J Biomech , vol.26 , pp. 1377-1388
    • Ojha, M.1
  • 21
    • 33846397823 scopus 로고    scopus 로고
    • Helical flow as fluid dynamic signature for atherogenesis risk in aortocoronary bypass: a numeric study
    • Morbiducci U, Ponzini R, Grigioni M, Redaelli A. Helical flow as fluid dynamic signature for atherogenesis risk in aortocoronary bypass: a numeric study. J Biomech 2007;40:519-34.
    • (2007) J Biomech , vol.40 , pp. 519-534
    • Morbiducci, U.1    Ponzini, R.2    Grigioni, M.3    Redaelli, A.4
  • 22
    • 0021966255 scopus 로고
    • Pulsatile flow and atherosclerosis in the human carotid bifurcation
    • Ku DN, Giddens DP, Zarins CK, Glagov S. Pulsatile flow and atherosclerosis in the human carotid bifurcation. Arteriosclerosis 1985;5:293-302.
    • (1985) Arteriosclerosis , vol.5 , pp. 293-302
    • Ku, D.N.1    Giddens, D.P.2    Zarins, C.K.3    Glagov, S.4
  • 23
    • 0024848297 scopus 로고
    • Pulsatile non-Newtonian blood flow simulation through a bifurcation with an aneurysm
    • Perktold K, Peter R, Resch M. Pulsatile non-Newtonian blood flow simulation through a bifurcation with an aneurysm. Biorheology 1989;26:1011-30.
    • (1989) Biorheology , vol.26 , pp. 1011-1030
    • Perktold, K.1    Peter, R.2    Resch, M.3
  • 24
    • 0029016955 scopus 로고
    • Differential characterization of blood flow, velocity, and vascular resistance between proximal and distal normal epicardial human coronary arteries: analysis by intracoronary Doppler spectral flow velocity
    • Ofili EO, Kern MJ, St Vrain JA, etal. Differential characterization of blood flow, velocity, and vascular resistance between proximal and distal normal epicardial human coronary arteries: analysis by intracoronary Doppler spectral flow velocity. Am Heart J 1995;130:37-46.
    • (1995) Am Heart J , vol.130 , pp. 37-46
    • Ofili, E.O.1    Kern, M.J.2    St Vrain, J.A.3
  • 25
    • 50349097421 scopus 로고    scopus 로고
    • Blood flow and macromolecular transport in complex blood vessels
    • Hong J, Wei L, Fu C, Tan W. Blood flow and macromolecular transport in complex blood vessels. Clin Biomech 2008;23:S125-9.
    • (2008) Clin Biomech , vol.23
    • Hong, J.1    Wei, L.2    Fu, C.3    Tan, W.4
  • 27
    • 0033485806 scopus 로고    scopus 로고
    • Hemodynamic shear stress and its role in atherosclerosis
    • Malek AM, Alper SL, Izumo S. Hemodynamic shear stress and its role in atherosclerosis. JAMA 1999;282:2035-42.
    • (1999) JAMA , vol.282 , pp. 2035-2042
    • Malek, A.M.1    Alper, S.L.2    Izumo, S.3
  • 30
    • 0034869192 scopus 로고    scopus 로고
    • Does stent design affect probability of restenosis? A randomized trial comparing Multilink stents with GFX stents
    • Yoshitomi Y, Kojima S, Yano M, etal. Does stent design affect probability of restenosis? A randomized trial comparing Multilink stents with GFX stents. Am Heart J 2001;142:445-51.
    • (2001) Am Heart J , vol.142 , pp. 445-451
    • Yoshitomi, Y.1    Kojima, S.2    Yano, M.3
  • 31
    • 0036181345 scopus 로고    scopus 로고
    • Control of the shape of a thrombus-neointima-like structure by blood shear stress
    • Liu SQ, Zhong L, Goldman J. Control of the shape of a thrombus-neointima-like structure by blood shear stress. J Biomech Eng 2002;124:30-6.
    • (2002) J Biomech Eng , vol.124 , pp. 30-36
    • Liu, S.Q.1    Zhong, L.2    Goldman, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.