메뉴 건너뛰기




Volumn 37, Issue 5, 2011, Pages 788-797

Toward Noninvasive Blood Pressure Assessment in Arteries by Using Ultrasound

Author keywords

Cardiovascular disease; Cross correlation; Local pressure estimation; Pulse wave velocity

Indexed keywords

CARDIO-VASCULAR DISEASE; CROSS CORRELATIONS; CROSS SECTIONAL AREA; LINEAR ARRAYS; LOCAL PRESSURE ESTIMATION; PRESSURE ESTIMATION; PRESSURE VALUES; PRESSURE WAVEFORMS; PULSATING FLOW; PULSE WAVE VELOCITY; RADIO-FREQUENCY DATUM; RHEOLOGIC PROPERTY; SIMULTANEOUS ESTIMATION; ULTRASOUND SCANNERS; VELOCITY PROFILES; VELOCITY VECTORS; VESSEL WALLS; WAVE FORMS;

EID: 79954631340     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2011.01.020     Document Type: Article
Times cited : (58)

References (35)
  • 1
    • 78049529940 scopus 로고    scopus 로고
    • Perpendicular ultrasound velocity measurements by cross-correlation of RF data: Part A: Validation in a straight tube
    • Beulen B.W.A.M.M., Bijnens N., Rutten M.C.M., Brands P.J., van de Vosse F.N. Perpendicular ultrasound velocity measurements by cross-correlation of RF data: Part A: Validation in a straight tube. Exp Fluids 2010, 49:1177-1186.
    • (2010) Exp Fluids , vol.49 , pp. 1177-1186
    • Beulen, B.W.A.M.M.1    Bijnens, N.2    Rutten, M.C.M.3    Brands, P.J.4    van de Vosse, F.N.5
  • 2
    • 78650604891 scopus 로고    scopus 로고
    • Perpendicular ultrasound velocity measurement by 2-D cross-correlation of RF data. Part B: Volume flow estimation in curved vessels
    • Beulen B.W.A.M.M., Verkaik A.C., Bijnens N., Rutten M.C.M., van de Vosse F.N. Perpendicular ultrasound velocity measurement by 2-D cross-correlation of RF data. Part B: Volume flow estimation in curved vessels. Exp Fluids 2010, 49:1219-1229.
    • (2010) Exp Fluids , vol.49 , pp. 1219-1229
    • Beulen, B.W.A.M.M.1    Verkaik, A.C.2    Bijnens, N.3    Rutten, M.C.M.4    van de Vosse, F.N.5
  • 3
    • 0033613192 scopus 로고    scopus 로고
    • Association between local pulse pressure, mean blood pressure, and large-artery remodeling
    • Boutouyrie P., Bussy C., Lacolley P., Girerd X., Laloux B., Laurent S. Association between local pulse pressure, mean blood pressure, and large-artery remodeling. Circulation 1999, 100:1387-1393.
    • (1999) Circulation , vol.100 , pp. 1387-1393
    • Boutouyrie, P.1    Bussy, C.2    Lacolley, P.3    Girerd, X.4    Laloux, B.5    Laurent, S.6
  • 4
    • 0030876893 scopus 로고    scopus 로고
    • A radio-frequency domain complex cross-correlation model to estimate blood flow velocity and tissue motion by means of ultrasound
    • Brands P.J., Hoeks A.P.G., Ledoux L.A.F., Reneman R.S. A radio-frequency domain complex cross-correlation model to estimate blood flow velocity and tissue motion by means of ultrasound. Ultrasound Med Biol 1997, 23:911-920.
    • (1997) Ultrasound Med Biol , vol.23 , pp. 911-920
    • Brands, P.J.1    Hoeks, A.P.G.2    Ledoux, L.A.F.3    Reneman, R.S.4
  • 5
    • 0029739654 scopus 로고    scopus 로고
    • A noninvasive method to estimate arterial impedance by means of assessment of local diameter change and the local center-line blood flow velocity using ultrasound
    • Brands P.J., Hoeks A.P.G., Rutten M.C.M., Reneman R.S. A noninvasive method to estimate arterial impedance by means of assessment of local diameter change and the local center-line blood flow velocity using ultrasound. Ultrasound Med Biol 1996, 22:895-905.
    • (1996) Ultrasound Med Biol , vol.22 , pp. 895-905
    • Brands, P.J.1    Hoeks, A.P.G.2    Rutten, M.C.M.3    Reneman, R.S.4
  • 6
    • 0032884654 scopus 로고    scopus 로고
    • An integrated system for the noninvasive assessment of vessel wall and hemodynamic properties of large arteries by means of ultrasound
    • Brands P.J., Hoeks A.P.G., Willigers J.M., Willekes C., Reneman R.S. An integrated system for the noninvasive assessment of vessel wall and hemodynamic properties of large arteries by means of ultrasound. Eur J Ultrasound 1999, 9:257-266.
    • (1999) Eur J Ultrasound , vol.9 , pp. 257-266
    • Brands, P.J.1    Hoeks, A.P.G.2    Willigers, J.M.3    Willekes, C.4    Reneman, R.S.5
  • 7
    • 0032409973 scopus 로고    scopus 로고
    • A noninvasive method to estimate pulse wave velocity in arteries locally by means of ultrasound
    • Brands P.J., Willigers J.M., Ledoux L.A.F., Reneman R.S., Hoeks A.P.G. A noninvasive method to estimate pulse wave velocity in arteries locally by means of ultrasound. Ultrasound Med Biol 1998, 24:1325-1335.
    • (1998) Ultrasound Med Biol , vol.24 , pp. 1325-1335
    • Brands, P.J.1    Willigers, J.M.2    Ledoux, L.A.F.3    Reneman, R.S.4    Hoeks, A.P.G.5
  • 9
    • 0032991356 scopus 로고    scopus 로고
    • Influence of the non-Newtonian properties of blood on the flow in large arteries: Unsteady flow in a 90 degree curved tube
    • Gijsen F.J.H., van de Vosse F.N., Janssen J.D. Influence of the non-Newtonian properties of blood on the flow in large arteries: Unsteady flow in a 90 degree curved tube. J Biomech 1999, 32:705-713.
    • (1999) J Biomech , vol.32 , pp. 705-713
    • Gijsen, F.J.H.1    van de Vosse, F.N.2    Janssen, J.D.3
  • 10
    • 34247527823 scopus 로고    scopus 로고
    • Measurement of local pulse wave velocity: Effects of signal processing on precision
    • 774-481
    • Hermeling E., Reesink K.D., Reneman R.S., Hoeks A.P.G. Measurement of local pulse wave velocity: Effects of signal processing on precision. Ultrasound Med Biol 2007, 33. 774-481.
    • (2007) Ultrasound Med Biol , vol.33
    • Hermeling, E.1    Reesink, K.D.2    Reneman, R.S.3    Hoeks, A.P.G.4
  • 14
    • 0034892079 scopus 로고    scopus 로고
    • Determination of wave speed and wave separation in arteries
    • Khir A.W., O'Brien A., Gibbs J.S.R., Parker K.H. Determination of wave speed and wave separation in arteries. J Biomech 2001, 34:1145-1155.
    • (2001) J Biomech , vol.34 , pp. 1145-1155
    • Khir, A.W.1    O'Brien, A.2    Gibbs, J.S.R.3    Parker, K.H.4
  • 17
    • 1442299320 scopus 로고    scopus 로고
    • Simultaneous assessment of diameter and pressure waveforms in the carotid artery
    • Meinders J.M., Hoeks A.P.G. Simultaneous assessment of diameter and pressure waveforms in the carotid artery. Ultrasound Med Biol 2004, 39:147-154.
    • (2004) Ultrasound Med Biol , vol.39 , pp. 147-154
    • Meinders, J.M.1    Hoeks, A.P.G.2
  • 18
    • 0035739994 scopus 로고    scopus 로고
    • Assessment of local pulse wave velocity in arteries using 2-D distension waveforms
    • Meinders J.M., Kornet L., Brands P.J., Hoeks A.P.G. Assessment of local pulse wave velocity in arteries using 2-D distension waveforms. Ultrason Imaging 2000, 23:199-215.
    • (2000) Ultrason Imaging , vol.23 , pp. 199-215
    • Meinders, J.M.1    Kornet, L.2    Brands, P.J.3    Hoeks, A.P.G.4
  • 19
    • 0031454018 scopus 로고    scopus 로고
    • Sphygmomanometrically determined pulse pressure is a powerful independent predictor of recurrent events after myocardial infarction in patients with impaired left ventricular function
    • Mitchell G.F., Moye L.A., Braunwald E., Rouleau J.L., Bernstein V., Geltman E.M., Flaker G.C., Pfeffer M.A. Sphygmomanometrically determined pulse pressure is a powerful independent predictor of recurrent events after myocardial infarction in patients with impaired left ventricular function. Circulation 1997, 96:4254-4260.
    • (1997) Circulation , vol.96 , pp. 4254-4260
    • Mitchell, G.F.1    Moye, L.A.2    Braunwald, E.3    Rouleau, J.L.4    Bernstein, V.5    Geltman, E.M.6    Flaker, G.C.7    Pfeffer, M.A.8
  • 20
    • 0342321365 scopus 로고
    • Development of an analog computer for the human systemic circulatory system
    • North Holland Publishing Co., Amsterdam, 29-44, A. Noordergraaf, G.N. Jager, N. Westerhof (Eds.)
    • Noordergraaf A. Development of an analog computer for the human systemic circulatory system. Circulatory analog computers 1963, North Holland Publishing Co., Amsterdam, 29-44. A. Noordergraaf, G.N. Jager, N. Westerhof (Eds.).
    • (1963) Circulatory analog computers
    • Noordergraaf, A.1
  • 21
    • 0036277861 scopus 로고    scopus 로고
    • Ultrasound based vessel wall tracking: An auto-correlation technique with RF center frequency estimation
    • Rabben S.I., Bjaerum S., Sorhus V., Torp H. Ultrasound based vessel wall tracking: An auto-correlation technique with RF center frequency estimation. Ultrasound Med Biol 2002, 28:505-517.
    • (2002) Ultrasound Med Biol , vol.28 , pp. 505-517
    • Rabben, S.I.1    Bjaerum, S.2    Sorhus, V.3    Torp, H.4
  • 23
    • 0033991138 scopus 로고    scopus 로고
    • Noninvasive vascular ultrasound: An asset in vascular medicine
    • Reneman R.S., Hoeks A.P.G. Noninvasive vascular ultrasound: An asset in vascular medicine. Cardiovasc Res 2000, 45:27-35.
    • (2000) Cardiovasc Res , vol.45 , pp. 27-35
    • Reneman, R.S.1    Hoeks, A.P.G.2
  • 25
    • 33750820187 scopus 로고    scopus 로고
    • Noninvasive simultaneous assessment of wall shear rate and wall distension in carotid arteries
    • Tortoli P., Morganti T., Bambi G., Palombo C., Ramnarine K.V. Noninvasive simultaneous assessment of wall shear rate and wall distension in carotid arteries. Ultrasound Med Biol 2006, 32:1661-1670.
    • (2006) Ultrasound Med Biol , vol.32 , pp. 1661-1670
    • Tortoli, P.1    Morganti, T.2    Bambi, G.3    Palombo, C.4    Ramnarine, K.V.5
  • 27
    • 61849099272 scopus 로고    scopus 로고
    • Estimation of volume flow in curved tubes based on analytical and computational analysis of axial velocity profiles
    • 023602-1/13
    • Verkaik A.C., Beulen B.W.A.M.M., Rutten M.C.M., Bogaerds A.C.B., van de Vosse F.N. Estimation of volume flow in curved tubes based on analytical and computational analysis of axial velocity profiles. Phys Fluids 2009, 21. 023602-1/13.
    • (2009) Phys Fluids , vol.21
    • Verkaik, A.C.1    Beulen, B.W.A.M.M.2    Rutten, M.C.M.3    Bogaerds, A.C.B.4    van de Vosse, F.N.5
  • 28
    • 0035726187 scopus 로고    scopus 로고
    • Carotid pressure is a better predictor of coronary artery disease severity than brachial pressure
    • Waddell T.K., Dart A.M., Medley T.L., Cameron J.D., Kingwell B.A. Carotid pressure is a better predictor of coronary artery disease severity than brachial pressure. Hypertension 2001, 38:927-931.
    • (2001) Hypertension , vol.38 , pp. 927-931
    • Waddell, T.K.1    Dart, A.M.2    Medley, T.L.3    Cameron, J.D.4    Kingwell, B.A.5
  • 33
    • 55249091059 scopus 로고
    • Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is known
    • Womersley J.R. Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is known. J Physiol 1955, 127:553-563.
    • (1955) J Physiol , vol.127 , pp. 553-563
    • Womersley, J.R.1
  • 34
    • 79954633826 scopus 로고
    • An elastic tube theory of pulse transmission and oscillatory flow in mammalian arteries. Technical report, Wright Air Development Centre TR56-614
    • Womersley JR. An elastic tube theory of pulse transmission and oscillatory flow in mammalian arteries. Technical report, Wright Air Development Centre TR56-614, 1957.
    • (1957)
    • Womersley, J.R.1
  • 35
    • 33750802957 scopus 로고    scopus 로고
    • Measurement of wave velocity in arterial walls with ultrasound transducers
    • Zhang X., Greenleaf J.F. Measurement of wave velocity in arterial walls with ultrasound transducers. Ultrasound Med Biol 2006, 32:1655-1660.
    • (2006) Ultrasound Med Biol , vol.32 , pp. 1655-1660
    • Zhang, X.1    Greenleaf, J.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.