메뉴 건너뛰기




Volumn 21, Issue 4, 2011, Pages 712-721

CT comparison of visual and computerised quantification of coronary stenosis according to plaque composition

Author keywords

Computed tomography; Computer aided diagnosis; Coronary stenosis; Plaque composition; Quantitative coronary angiography

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTERY CALCIFICATION; ARTICLE; ATHEROSCLEROTIC PLAQUE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTER ASSISTED DIAGNOSIS; CORONARY ARTERY ATHEROSCLEROSIS; CORONARY ARTERY OBSTRUCTION; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; FEMALE; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PREDICTIVE VALUE; PRIORITY JOURNAL; QUANTITATIVE CORONARY ANGIOGRAPHY; RETROSPECTIVE STUDY; SENSITIVITY AND SPECIFICITY;

EID: 79954607398     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-010-1970-9     Document Type: Article
Times cited : (12)

References (29)
  • 1
    • 31144447047 scopus 로고    scopus 로고
    • Usefulness of multidetector row spiral computed tomography with 64- x 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses
    • DOI 10.1016/j.amjcard.2005.08.050, PII S0002914905018205
    • D Ropers J Rixe K Anders A Küttner U Baum W Bautz WG Daniel S Achenbach 2006 Usefulness of multidetector row spiral computed tomography with 64- ×0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses Am J Cardiol 97 343 348 16442393 10.1016/j.amjcard.2005.08.050 (Pubitemid 43133047)
    • (2006) American Journal of Cardiology , vol.97 , Issue.3 , pp. 343-348
    • Ropers, D.1    Rixe, J.2    Anders, K.3    Kuttner, A.4    Baum, U.5    Bautz, W.6    Daniel, W.G.7    Achenbach, S.8
  • 3
    • 0037109216 scopus 로고    scopus 로고
    • Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography
    • DOI 10.1161/01.CIR.0000037222.58317.3D
    • K Nieman F Cademartiri PA Lemos R Raaijmakers PM Pattynama PJ de Feyter 2002 Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography Circulation 106 2051 2054 12379572 10.1161/01.CIR.0000037222.58317.3D (Pubitemid 35192809)
    • (2002) Circulation , vol.106 , Issue.16 , pp. 2051-2054
    • Nieman, K.1    Cademartiri, F.2    Lemos, P.A.3    Raaijmakers, R.4    Pattynama, P.M.T.5    De Feyter, P.J.6
  • 4
    • 0037432175 scopus 로고    scopus 로고
    • Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction
    • DOI 10.1161/01.CIR.0000055738.31551.A9
    • D Ropers U Baum K Pohle, et al. 2003 Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction Circulation 107 664 666 12578863 10.1161/01.CIR. 0000055738.31551.A9 (Pubitemid 36222588)
    • (2003) Circulation , vol.107 , Issue.5 , pp. 664-666
    • Ropers, D.1    Baum, U.2    Pohle, K.3    Anders, K.4    Ulzheimer, S.5    Ohnesorge, B.6    Schlundt, C.7    Bautz, W.8    Daniel, W.G.9    Achenbach, S.10
  • 7
    • 22844448174 scopus 로고    scopus 로고
    • Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography
    • DOI 10.1016/j.jacc.2005.05.056, PII S0735109705013148
    • GL Raff MJ Gallagher WW O'Neill, et al. 2005 Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography J Am Coll Cardiol 46 552 557 16053973 10.1016/j.jacc.2005.05.056 (Pubitemid 41040301)
    • (2005) Journal of the American College of Cardiology , vol.46 , Issue.3 , pp. 552-557
    • Raff, G.L.1    Gallagher, M.J.2    O'Neill, W.W.3    Goldstein, J.A.4
  • 9
    • 33846219116 scopus 로고    scopus 로고
    • Coronary artery stenosis quantification using multislice computed tomography
    • DOI 10.1097/01.rli.0000251569.01317.60, PII 0000442420070200000002
    • M Dewey W Rutsch D Schnapauff, et al. 2007 Coronary artery stenosis quantification using multislice computed tomography Invest Radiol 42 78 84 17220725 10.1097/01.rli.0000251569.01317.60 (Pubitemid 46104887)
    • (2007) Investigative Radiology , vol.42 , Issue.2 , pp. 78-84
    • Dewey, M.1    Rutsch, W.2    Schnapauff, D.3    Teige, F.4    Hamm, B.5
  • 12
    • 34248671112 scopus 로고    scopus 로고
    • Visual and automatic grading of coronary artery stenoses with 64-slice CT angiography in reference to invasive angiography
    • DOI 10.1007/s00330-006-0512-y
    • S Busch TR Johnson K Nikolaou, et al. 2007 Visual and automatic grading of coronary artery stenoses with 64-slice CT angiography in reference to invasive angiography Eur Radiol 17 1445 1451 17180326 10.1007/s00330-006-0512-y (Pubitemid 46767592)
    • (2007) European Radiology , vol.17 , Issue.6 , pp. 1445-1451
    • Busch, S.1    Johnson, T.R.C.2    Nikolaou, K.3    Ziegler, F.4    Knez, A.5    Reiser, M.F.6    Becker, C.R.7
  • 13
    • 35148867562 scopus 로고    scopus 로고
    • Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease
    • DOI 10.1093/eurheartj/ehm294
    • AW Leber T Johnson A Becker F von Ziegler J Tittus K Nikolaou M Reiser G Steinbeck CR Becker A Knez 2007 Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease Eur Heart J 28 2354 2360 17644815 10.1093/eurheartj/ ehm294 (Pubitemid 47537778)
    • (2007) European Heart Journal , vol.28 , Issue.19 , pp. 2354-2360
    • Leber, A.W.1    Johnson, T.2    Becker, A.3    Von Ziegler, F.4    Tittus, J.5    Nikolaou, K.6    Reiser, M.7    Steinbeck, G.8    Becker, C.R.9    Knez, A.10
  • 14
    • 0037325935 scopus 로고    scopus 로고
    • Patient dose in cardiac computed tomography
    • DOI 10.1007/s00059-003-2447-2
    • CH McCollough 2003 Patient dose in cardiac computed tomography Herz 28 1 6 12616315 10.1007/s00059-003-2447-2 (Pubitemid 36262466)
    • (2003) Herz , vol.28 , Issue.1 , pp. 1-6
    • McCollough, C.H.1
  • 15
    • 0016490238 scopus 로고
    • A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association
    • 1116248 1:STN:280:DyaE2M7htFersg%3D%3D
    • WG Austen JE Edwards RL Frye, et al. 1975 A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association Circulation 51 5 40 1116248 1:STN:280:DyaE2M7htFersg%3D%3D
    • (1975) Circulation , vol.51 , pp. 5-40
    • Austen, W.G.1    Edwards, J.E.2    Frye, R.L.3
  • 17
    • 0347357884 scopus 로고    scopus 로고
    • Detection of Calcified and Noncalcified Coronary Atherosclerotic Plaque by Contrast-Enhanced, Submillimeter Multidetector Spiral Computed Tomography: A Segment-Based Comparison with Intravascular Ultrasound
    • DOI 10.1161/01.CIR.0000111517.69230.0F
    • S Achenbach F Moselewski D Ropers, et al. 2004 Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography: a segmentbased comparison with intravascular ultrasound Circulation 109 14 17 14691045 10.1161/01.CIR.0000111517.69230.0F (Pubitemid 38056013)
    • (2004) Circulation , vol.109 , Issue.1 , pp. 14-17
    • Achenbach, S.1    Moselewski, F.2    Ropers, D.3    Ferencik, M.4    Hoffmann, U.5    MacNeill, B.6    Pohle, K.7    Baum, U.8    Anders, K.9    Jang, I.-K.10    Daniel, W.G.11    Brady, T.J.12
  • 22
  • 23
    • 7544220286 scopus 로고    scopus 로고
    • Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease: Patient- versus segment-based analysis
    • DOI 10.1161/01.CIR.0000145614.07427.9F
    • U Hoffmann F Moselewski RC Cury, et al. 2004 Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease: patient-versus segment-based analysis Circulation 110 2638 2643 15492297 10.1161/01.CIR.0000145614.07427.9F (Pubitemid 39453013)
    • (2004) Circulation , vol.110 , Issue.17 , pp. 2638-2643
    • Hoffmann, U.1    Moselewski, F.2    Cury, R.C.3    Ferencik, M.4    Jang, I.-K.5    Diaz, L.J.6    Abbara, S.7    Brady, T.J.8    Achenbach, S.9
  • 24
    • 34147101153 scopus 로고    scopus 로고
    • New technology for noninvasive evaluation of coronary artery disease
    • DOI 10.1161/CIRCULATIONAHA.106.629808, PII 0000301720070320000020
    • MF Di Carli R Hachamovitch 2007 New technology for noninvasive evaluation of coronary artery disease Circulation 115 1464 1480 17372188 10.1161/CIRCULATIONAHA.106.629808 (Pubitemid 46648384)
    • (2007) Circulation , vol.115 , Issue.11 , pp. 1464-1480
    • Di Carli, M.F.1    Hachamovitch, R.2
  • 26
    • 77952095551 scopus 로고    scopus 로고
    • Automated computer-aided stenosis detection at coronary CT angiography: Initial experience
    • 19890640 10.1007/s00330-009-1644-7
    • E Arnoldi M Gebregziabher UJ Schoepf R Goldenberg L Ramos-Duran PL Zwerner, et al. 2010 Automated computer-aided stenosis detection at coronary CT angiography: initial experience Eur Radiol 20 1160 1167 19890640 10.1007/s00330-009-1644-7
    • (2010) Eur Radiol , vol.20 , pp. 1160-1167
    • Arnoldi, E.1    Gebregziabher, M.2    Schoepf, U.J.3    Goldenberg, R.4    Ramos-Duran, L.5    Zwerner, P.L.6
  • 27
    • 0035312809 scopus 로고    scopus 로고
    • American College of Cardiology clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound studies (IVUS)
    • DOI 10.1016/S0735-1097(01)01175-5, PII S0735109701011755
    • GS Mintz SE Nissen WD Anderson SR Bailey R Erbel PJ Fitzgerald, et al. 2001 American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents J Am Coll Cardiol 37 1478 1492 11300468 10.1016/S0735-1097(01)01175-5 1:STN:280:DC%2BD3M3gvFKgsg%3D%3D (Pubitemid 32295620)
    • (2001) Journal of the American College of Cardiology , vol.37 , Issue.5 , pp. 1478-1492
    • Zipes, D.P.1
  • 28
    • 32844470811 scopus 로고    scopus 로고
    • Characterization of coronary atherosclerotic plaques by multidetector computed tomography
    • DOI 10.1016/j.amjcard.2005.09.096, PII S0002914905019843
    • PM Carrascosa CM Capuñay P Garcia-Merletti J Carrascosa MF Garcia 2006 Characterization of coronary atherosclerotic plaques by multidetector computed tomography Am J Cardiol 97 598 602 16490420 10.1016/j.amjcard.2005.09. 096 (Pubitemid 43255022)
    • (2006) American Journal of Cardiology , vol.97 , Issue.5 , pp. 598-602
    • Carrascosa, P.M.1    Capunay, C.M.2    Garcia-Merletti, P.3    Carrascosa, J.4    Garcia, M.J.5
  • 29
    • 39749104658 scopus 로고    scopus 로고
    • Identification and quantification of coronary atherosclerotic plaques: A comparison of 64-MDCT and intravascular ultrasound
    • DOI 10.2214/AJR.07.2763
    • J Sun Z Zhang B Lu W Yu Y Yang Y Zhou, et al. 2008 Identification and quantification of coronary atherosclerotic plaques: a comparison of 64-MDCT and intravascular ultrasound AJR Am J Roentgenol 190 748 754 18287448 10.2214/AJR.07.2763 (Pubitemid 351304521)
    • (2008) American Journal of Roentgenology , vol.190 , Issue.3 , pp. 748-754
    • Sun, J.1    Zhang, Z.2    Lu, B.3    Yu, W.4    Yang, Y.5    Zhou, Y.6    Wang, Y.7    Fan, Z.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.