메뉴 건너뛰기




Volumn 65, Issue 5, 2011, Pages 1346-1351

The effect of reducing repetition time TR on the measurement of liver R2 for the purpose of measuring liver iron concentration

Author keywords

iron overload; liver iron concentration; magnetic resonance imaging

Indexed keywords

MAGNETIC RESONANCE IMAGING;

EID: 79954605536     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22712     Document Type: Article
Times cited : (15)

References (12)
  • 3
    • 0842283228 scopus 로고    scopus 로고
    • Non-invasive assessment of hepatic iron stores by MRI
    • DOI 10.1016/S0140-6736(04)15436-6
    • Gandon Y, Olivie D, Guyader D, Aube C, Oberti F, Sebille V, Deugnier Y,. Non-invasive assessment of hepatic iron stores by MRI. Lancet 2004; 363: 357-362. (Pubitemid 38169542)
    • (2004) Lancet , vol.363 , Issue.9406 , pp. 357-362
    • Gandon, Y.1    Olivie, D.2    Guyader, D.3    Aube, C.4    Oberti, F.5    Sebille, V.6    Deugnier, Y.7
  • 6
    • 23744459788 scopus 로고    scopus 로고
    • MRI R2 and R2* mapping accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patients
    • DOI 10.1182/blood-2004-10-3982
    • Wood JC, Enriquez C, Ghugre N, Tyzka JM, Carson S, Nelson MD, Coates TD,. MRI R2 and R2* mapping accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patients. Blood 2005; 106: 1460-1465. (Pubitemid 41129616)
    • (2005) Blood , vol.106 , Issue.4 , pp. 1460-1465
    • Wood, J.C.1    Enriquez, C.2    Ghugre, N.3    Tyzka, J.M.4    Carson, S.5    Nelson, M.D.6    Coates, T.D.7
  • 8
    • 0025196776 scopus 로고
    • 1 in patients with liver cirrhosis: An in vivo MRI study
    • DOI 10.1016/0730-725X(90)90137-Q
    • Thomsen C, Christoffersen P, Henriksen O, Juhl E,. Prolonged T1 in patients with liver cirrhosis: an in vivo MRI study. Magn Reson Imaging 1990; 8: 599-604. (Pubitemid 20321976)
    • (1990) Magnetic Resonance Imaging , vol.8 , Issue.5 , pp. 599-604
    • Thomsen, C.1    Christoffersen, P.2    Henriksen, O.3    Juhl, E.4
  • 9
    • 9244220587 scopus 로고    scopus 로고
    • Single spin-echo proton transverse relaxometry of iron-loaded liver
    • DOI 10.1002/nbm.905
    • St Pierre TG, Clark PR, Chua-Anusorn W,. Single spin-echo proton transverse relaxometry of iron-loaded liver. NMR Biomed 2004; 17: 446-458. (Pubitemid 39549422)
    • (2004) NMR in Biomedicine , vol.17 , Issue.7 , pp. 446-458
    • St Pierre, T.G.1    Clark, P.R.2    Chua-anusorn, W.3
  • 10
    • 0042808828 scopus 로고    scopus 로고
    • 2 measurement of iron-loaded liver
    • DOI 10.1016/S0730-725X(03)00080-8
    • Clark PR, Chua-anusorn W, St Pierre TG,. Bi-exponential proton transverse relaxation rate (R2) image analysis using RF field intensity-weighted spin density projection: potential for R2 measurement of iron-loaded liver. Magn Reson Imaging 2003; 21: 519-530. (Pubitemid 36899085)
    • (2003) Magnetic Resonance Imaging , vol.21 , Issue.5 , pp. 519-530
    • Clark, P.R.1    Chua-anusorn, W.2    St. Pierre, T.G.3
  • 12
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • DOI 10.1191/096228099673819272
    • Bland JM, Altman DG,. Measuring agreement in method comparison studies. Stat Methods Med Res 1999; 8: 135-160. (Pubitemid 29425900)
    • (1999) Statistical Methods in Medical Research , vol.8 , Issue.2 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.