메뉴 건너뛰기




Volumn 26, Issue 2, 2011, Pages 125-129

Analysis of 2-propanol in exhaled breath using in situ enrichment and cataluminescence detection

Author keywords

2 propanol; cataluminescence; exhaled breath; nanomaterials

Indexed keywords

VOLATILE ORGANIC COMPOUNDS;

EID: 79954592036     PISSN: 15227235     EISSN: 15227243     Source Type: Journal    
DOI: 10.1002/bio.1194     Document Type: Article
Times cited : (18)

References (29)
  • 3
    • 4143053648 scopus 로고    scopus 로고
    • Diagnostic potential of breath analysis - Focus on volatile organic compounds
    • DOI 10.1016/j.cccn.2004.04.023, PII S0009898104002256
    • Miekisch W, Schubert JK, Noeldge-Schomburg GFE., Diagnostic potential of breath analysis-focus on volatile organic compounds. Clin Chim Acta 2004; 347: 25-39. (Pubitemid 39099603)
    • (2004) Clinica Chimica Acta , vol.347 , Issue.1-2 , pp. 25-39
    • Miekisch, W.1    Schubert, J.K.2    Noeldge-Schomburg, G.F.E.3
  • 4
    • 34250667846 scopus 로고    scopus 로고
    • Human exhaled air analytics: Biomarkers of diseases
    • DOI 10.1002/bmc.835
    • Buszewski B, Kesy M, Ligor T, Amann A., Human exhaled air analytics: Biomarkers of diseases. Biomed Chromatogr 2007; 21: 553-66. (Pubitemid 46937852)
    • (2007) Biomedical Chromatography , vol.21 , Issue.6 , pp. 553-566
    • Buszewski, B.1    Kesy, M.2    Ligor, T.3    Amann, A.4
  • 6
    • 33750211186 scopus 로고    scopus 로고
    • Measurement of ammonia in human breath with a liquid-film conductivity sensor
    • DOI 10.1021/ac060965m
    • Toda K, Li J, Dasgupta PK., Measurement of ammonia in human breath with a liquid-film conductivity sensor. Anal Chem 2006; 78: 7284-91. (Pubitemid 44607575)
    • (2006) Analytical Chemistry , vol.78 , Issue.20 , pp. 7284-7291
    • Toda, K.1    Li, J.2    Dasgupta, P.K.3
  • 7
    • 33745727661 scopus 로고    scopus 로고
    • Two-step preconcentration for analysis of exhaled gas of human breath with electronic nose
    • Cho SM, Kim YJ, Heo GS, Shin SM., Two-step preconcentration for analysis of exhaled gas of human breath with electronic nose. Sens Actuators B 2006; 117: 50-7.
    • (2006) Sens Actuators B , vol.117 , pp. 50-57
    • Cho, S.M.1    Kim, Y.J.2    Heo, G.S.3    Shin, S.M.4
  • 9
    • 0026544914 scopus 로고
    • The use of a transportable fourier-transform infrared (FTIR) spectrometer for the direct measurement of solvents in breath and ambient air.1. methanol
    • Franzblau A, Levine SP, Burgess LA, Qu QS, Schreck RM, Darcy JB., The use of a transportable fourier-transform infrared (FTIR) spectrometer for the direct measurement of solvents in breath and ambient air.1. methanol. Am Ind Hyg Assoc J 1992; 53: 221-7.
    • (1992) Am Ind Hyg Assoc J , vol.53 , pp. 221-227
    • Franzblau, A.1    Levine, S.P.2    Burgess, L.A.3    Qu, Q.S.4    Schreck, R.M.5    Darcy, J.B.6
  • 10
    • 33645003060 scopus 로고    scopus 로고
    • A longitudinal study of ammonia, acetone and propanol in the exhaled breath of 30 subjects using selected ion flow tube mass spectrometry, SIFT-MS
    • Turner C, Spanel P, Smith D., A longitudinal study of ammonia, acetone and propanol in the exhaled breath of 30 subjects using selected ion flow tube mass spectrometry, SIFT-MS. Physiol Meas 2006; 27: 321-37.
    • (2006) Physiol Meas , vol.27 , pp. 321-337
    • Turner, C.1    Spanel, P.2    Smith, D.3
  • 11
    • 31044435855 scopus 로고    scopus 로고
    • The analysis of 1-propanol and 2-propanol in humid air samples using selected ion flow tube mass spectrometry
    • DOI 10.1002/rcm.2285
    • Wang TS, Carroll W, Lenny W, Boit P, Smith D., The analysis of 1-propanol and 2-propanol in humid air samples using selected ion flow tube mass spectrometry. Rapid Commun Mass Spectrom 2006; 20: 125-30. (Pubitemid 43121611)
    • (2006) Rapid Communications in Mass Spectrometry , vol.20 , Issue.2 , pp. 125-130
    • Wang, T.1    Carroll, W.2    Lenny, W.3    Boit, P.4    Smith, D.5
  • 13
    • 68149114145 scopus 로고    scopus 로고
    • Determining concentration patterns of volatile compounds in exhaled breath by PTR-MS
    • 027002.
    • Schwarz K, Filipiak W, Amann A., Determining concentration patterns of volatile compounds in exhaled breath by PTR-MS. J Breath Res 2009; 3: 027002.
    • (2009) J Breath Res , vol.3
    • Schwarz, K.1    Filipiak, W.2    Amann, A.3
  • 15
    • 67650745677 scopus 로고    scopus 로고
    • Multibed Needle Trap Devices for on Site Sampling and Preconcentration of Volatile Breath Biomarkers
    • Mieth M, Kischkel S, Schubert JK, Hein D, Miekisch W., Multibed Needle Trap Devices for on Site Sampling and Preconcentration of Volatile Breath Biomarkers. Anal Chem 2009; 81: 5851-7.
    • (2009) Anal Chem , vol.81 , pp. 5851-5857
    • Mieth, M.1    Kischkel, S.2    Schubert, J.K.3    Hein, D.4    Miekisch, W.5
  • 16
    • 67650707879 scopus 로고    scopus 로고
    • Breath acetone analysis with miniaturized sample preparation device: In-needle preconcentration and subsequent determination by gas chromatography-mass spectroscopy
    • Ueta I, Saito Y, Hosoe M, Okamoto M, Ohkita H, Shirai S, Tamura H, Jinno K., Breath acetone analysis with miniaturized sample preparation device: In-needle preconcentration and subsequent determination by gas chromatography-mass spectroscopy. J. Chromatogr. B 2009; 877: 2551-6.
    • (2009) J. Chromatogr. B , vol.877 , pp. 2551-2556
    • Ueta, I.1    Saito, Y.2    Hosoe, M.3    Okamoto, M.4    Ohkita, H.5    Shirai, S.6    Tamura, H.7    Jinno, K.8
  • 17
    • 0000738736 scopus 로고
    • Chemiluminescence during the catalysis of carbon monoxide oxidation on a thoria surface
    • Breysse M, Claudel B, Faure L, Guenin M, Williams RJ., Chemiluminescence during the catalysis of carbon monoxide oxidation on a thoria surface. J Catal 1976; 45: 137-44.
    • (1976) J Catal , vol.45 , pp. 137-144
    • Breysse, M.1    Claudel, B.2    Faure, L.3    Guenin, M.4    Williams, R.J.5
  • 18
    • 0002437827 scopus 로고
    • Chemiluminescence of anodized and etched silicon - Evidence for a luminescent siloxene-like layer on porous silicon
    • McCord P, Yau SL, Bard AJ., Chemiluminescence of anodized and etched silicon-evidence for a luminescent siloxene-like layer on porous silicon. Science 1992; 257: 68-9.
    • (1992) Science , vol.257 , pp. 68-69
    • McCord, P.1    Yau, S.L.2    Bard, A.J.3
  • 20
    • 0036139785 scopus 로고    scopus 로고
    • Development of a gas sensor utilizing chemiluminescence on nanosized titanium dioxide
    • DOI 10.1021/ac010450p
    • Zhu YF, Shi JJ, Zhang ZY, Zhang C, Zhang XR., Development of a gas sensor utilizing chemiluminescence on nanosized titanium dioxide. Anal Chem 2002; 74: 120-4. (Pubitemid 34044433)
    • (2002) Analytical Chemistry , vol.74 , Issue.1 , pp. 120-124
    • Zhu, Y.1    Shi, J.2    Zhang, Z.3    Zhang, C.4    Zhang, X.5
  • 21
    • 14744276240 scopus 로고    scopus 로고
    • Development of a detector for liquid chromatography based on aerosol chemiluminescence on porous alumina
    • DOI 10.1021/ac048816w
    • Lv Y, Zhang SC, Liu GH, Huang MW, Zhang XR., Development of a detector for liquid chromatography based on aerosol chemiluminescence on porous alumina. Anal Chem 2005; 77: 1518-25. (Pubitemid 40327895)
    • (2005) Analytical Chemistry , vol.77 , Issue.5 , pp. 1518-1525
    • Lv, Y.1    Zhang, S.2    Liu, G.3    Huang, M.4    Zhang, X.5
  • 22
    • 55549135341 scopus 로고    scopus 로고
    • Oxidation of Ethyl Ether on Borate Glass: Chemiluminescence, Mechanism, and Development of a Sensitive Gas Sensor
    • Hu J, Xu K, Jia Y, Lv Y, Li Y, Hou X., Oxidation of Ethyl Ether on Borate Glass: Chemiluminescence, Mechanism, and Development of a Sensitive Gas Sensor. Anal Chem 2008; 80: 7964-9.
    • (2008) Anal Chem , vol.80 , pp. 7964-7969
    • Hu, J.1    Xu, K.2    Jia, Y.3    Lv, Y.4    Li, Y.5    Hou, X.6
  • 23
    • 36448971296 scopus 로고    scopus 로고
    • Direct solid-support sample loading for fast cataluminescence determination of acetone in human plasma
    • Yang P, Lau CW, Liu X, Lu JZ., Direct solid-support sample loading for fast cataluminescence determination of acetone in human plasma. Anal Chem 2007; 79: 8476-85.
    • (2007) Anal Chem , vol.79 , pp. 8476-8485
    • Yang, P.1    Lau, C.W.2    Liu, X.3    Lu, J.Z.4
  • 24
    • 33751002974 scopus 로고    scopus 로고
    • A catalytic nanomaterial-based optical chemo-sensor array
    • DOI 10.1021/ja063632f
    • Na N, Zhang SC, Wang SA, Zhang XR., A catalytic nanomaterial-based optical chemo-sensor array. J Am Chem Soc 2006; 128: 14420-1. (Pubitemid 44749817)
    • (2006) Journal of the American Chemical Society , vol.128 , Issue.45 , pp. 14420-14421
    • Na, N.1    Zhang, S.2    Wang, S.3    Zhang, X.4
  • 25
    • 61449183613 scopus 로고    scopus 로고
    • Discrimination and Identification of Flavors with Catalytic Nanomaterial-Based Optical Chemosensor Array
    • Wu YY, Na N, Zhang S, Wang X, Liu D, Zhang XR., Discrimination and Identification of Flavors with Catalytic Nanomaterial-Based Optical Chemosensor Array. Anal Chem 2009; 81: 961-6.
    • (2009) Anal Chem , vol.81 , pp. 961-966
    • Wu, Y.Y.1    Na, N.2    Zhang, S.3    Wang, X.4    Liu, D.5    Zhang, X.R.6
  • 26
    • 56849096268 scopus 로고    scopus 로고
    • Development of a benzaldehyde sensor utilizing chemiluminescence on nanosized Y2O3
    • Wu YY, Zhang SC, Wang X, Na N, Zhang ZX., Development of a benzaldehyde sensor utilizing chemiluminescence on nanosized Y2O3. Luminescence 2008; 23: 376-80.
    • (2008) Luminescence , vol.23 , pp. 376-380
    • Wu, Y.Y.1    Zhang, S.C.2    Wang, X.3    Na, N.4    Zhang, Z.X.5
  • 27
    • 25444508437 scopus 로고    scopus 로고
    • A research on determination of explosive gases utilizing cataluminescence sensor array
    • Cao XO, Zhang XR., A research on determination of explosive gases utilizing cataluminescence sensor array. Luminescence 2005; 20: 243-50.
    • (2005) Luminescence , vol.20 , pp. 243-250
    • Cao, X.O.1    Zhang, X.R.2
  • 28
  • 29
    • 67949089536 scopus 로고    scopus 로고
    • Development of a sensitive gas sensor by trapping the analytes on nanomaterials and in situ cataluminescence detection
    • Wen F, Zhang SC, Na N, Wu YY, Zhang XR., Development of a sensitive gas sensor by trapping the analytes on nanomaterials and in situ cataluminescence detection. Sens Actuators B 2009; 141: 168-73.
    • (2009) Sens Actuators B , vol.141 , pp. 168-173
    • Wen, F.1    Zhang, S.C.2    Na, N.3    Wu, Y.Y.4    Zhang, X.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.