메뉴 건너뛰기




Volumn 135, Issue 4, 2011, Pages 516-524

Combined core needle biopsy and fine-needle aspiration with ancillary studies correlate highly with traditional techniques in the diagnosis of nodal-based lymphoma

Author keywords

Accuracy; Core needle biopsy; Fine needle aspiration; Flow cytometry; Immunohistochemistry; Lymphoma; Predictive diagnostic value

Indexed keywords

ABDOMEN; ADULT; AGED; ARTICLE; ASPIRATION BIOPSY; AXILLARY LYMPH NODE; BIOPSY; BIOPSY TECHNIQUE; BURKITT LYMPHOMA; CERVICAL LYMPH NODE; CHRONIC LYMPHATIC LEUKEMIA; CLAVICULAR LYMPH NODE; CONTROLLED STUDY; CORE NEEDLE BIOPSY; DIAGNOSTIC ACCURACY; DISEASE CLASSIFICATION; EXCISIONAL BIOPSY; FLOW CYTOMETRY; FOLLICULAR LYMPHOMA; GENETIC ANALYSIS; HISTOPATHOLOGY; HODGKIN DISEASE; HUMAN; HUMAN TISSUE; IMMUNOHISTOCHEMISTRY; INGUINAL LYMPH NODE; LARGE CELL LYMPHOMA; LYMPH NODE; LYMPH NODE HYPERPLASIA; LYMPHOCYTOMA; LYMPHOMA; MAJOR CLINICAL STUDY; MANTLE CELL LYMPHOMA; MARGINAL LYMPHOMA; MORPHOLOGY; NEEDLE BIOPSY; PELVIS; PREDICTIVE VALUE; PRIORITY JOURNAL; RETROPERITONEUM; SENSITIVITY AND SPECIFICITY; SMALL LYMPHOCYTIC LYMPHOMA; T CELL LYMPHOMA; THORAX;

EID: 79954570735     PISSN: 00029173     EISSN: 19437722     Source Type: Journal    
DOI: 10.1309/AJCP3WZ8ZDRJQDOU     Document Type: Article
Times cited : (83)

References (18)
  • 2
    • 0024394480 scopus 로고
    • Diagnostic fine needle core biopsy of deep lymph nodes for the diagnosis of lymphoma in patients unfit for surgery
    • DOI 10.1002/path.1711580206
    • Wotherspoon AC, Norton AJ, Lees WR, et al. Diagnostic fine needle core biopsy of deep lymph nodes for the diagnosis of lymphoma in patients unfit for surgery. J Pathol. 1989;158:115-121. (Pubitemid 19157013)
    • (1989) Journal of Pathology , vol.158 , Issue.2 , pp. 115-121
    • Wotherspoon, A.C.1    Norton, A.J.2    Lees, W.R.3    Shaw, P.4    Isaacson, P.G.5
  • 3
    • 0029395764 scopus 로고
    • The role of percutaneous needle biopsies in the original diagnosis of lymphoma: A prospective evaluation
    • Quinn SF, Sheley RC, Nelson HA, et al. The role of percutaneous needle biopsies in the original diagnosis of lymphoma: A prospective evaluation. J Vasc Interv Radiol. 1995;6:947-952.
    • (1995) J Vasc Interv Radiol , vol.6 , pp. 947-952
    • Quinn, S.F.1    Sheley, R.C.2    Nelson, H.A.3
  • 5
    • 0026071761 scopus 로고
    • Computed tomography (CT) and ultrasound (US) guided core biopsy in the management of non-Hodgkin's lymphoma
    • Whelan JS, Reznek RH, Daniell SJ, et al. Computed tomography (CT) and ultrasound (US) guided core biopsy in the management of non-Hodgkin's lymphoma. Br J Cancer. 1991;63:460-462.
    • (1991) Br J Cancer , vol.63 , pp. 460-462
    • Whelan, J.S.1    Reznek, R.H.2    Daniell, S.J.3
  • 8
    • 34447333399 scopus 로고    scopus 로고
    • Accuracy and cost-effectiveness of core needle biopsy in the evaluation of suspected lymphoma: A study of 101 cases
    • Lachar WA, Shahab I, Saad AJ. Accuracy and costeffectiveness of core needle biopsy in the evaluation of suspected lymphoma: A study of 101 cases. Arch Pathol Lab Med. 2007;131:1033-1039. (Pubitemid 47057890)
    • (2007) Archives of Pathology and Laboratory Medicine , vol.131 , Issue.7 , pp. 1033-1039
    • Lachar, W.A.1    Shahab, I.2    Saad, A.J.3
  • 14
    • 4143102719 scopus 로고    scopus 로고
    • Utility of fine-needle aspiration as a diagnostic technique in lymphoma
    • DOI 10.1200/JCO.2004.02.104
    • Hehn ST, Grogan TM, Miller TP. Utility of fine-needle aspiration as a diagnostic technique in lymphoma. J Clin Oncol. 2004;22:3046-3052. (Pubitemid 41103716)
    • (2004) Journal of Clinical Oncology , vol.22 , Issue.15 , pp. 3046-3052
    • Hehn, S.T.1    Grogan, T.M.2    Miller, T.P.3
  • 15
    • 0033639006 scopus 로고    scopus 로고
    • Utility of flow cytometry immunophenotyping for the diagnosis and classification of lymphoma in community hospital clinical needle aspiration/biopsies
    • Siebert JD, Weeks LM, List LW, et al. Utility of flow cytometry immunophenotyping for the diagnosis and classification of lymphoma in community hospital clinical needle aspiration/biopsies. Arch Pathol Lab Med. 2000;124:1792-1799.
    • (2000) Arch Pathol Lab Med , vol.124 , pp. 1792-1799
    • Siebert, J.D.1    Weeks, L.M.2    List, L.W.3
  • 16
    • 78751646173 scopus 로고    scopus 로고
    • CT-guided needle biopsy performed with modified coaxial technique in the diagnosis of malignant lymphomas [published online ahead of print June 23, 2010]
    • doi:10.1007/s11547-010-0559-3
    • Pedote P, Gaudio F, Moschetta M, et al. CT-guided needle biopsy performed with modified coaxial technique in the diagnosis of malignant lymphomas [published online ahead of print June 23, 2010]. Radiol Med. 2010;115:1292-1303. doi:10.1007/s11547-010-0559-3.
    • (2010) Radiol Med , vol.115 , pp. 1292-1303
    • Pedote, P.1    Gaudio, F.2    Moschetta, M.3
  • 17
    • 67349179160 scopus 로고    scopus 로고
    • Diagnostic precision of image-guided multisampling core needle biopsy of suspected lymphomas in a primary care hospital
    • Loubeyre P, McKee TA, Copercini M, et al. Diagnostic precision of image-guided multisampling core needle biopsy of suspected lymphomas in a primary care hospital. Br J Cancer. 2009;100:1771-1776.
    • (2009) Br J Cancer , vol.100 , pp. 1771-1776
    • Loubeyre, P.1    McKee, T.A.2    Copercini, M.3