메뉴 건너뛰기




Volumn 39, Issue 3, 2011, Pages 215-221

Comparison of the influence of cataract and pupil size on retinal nerve fibre layer thickness measurements with time-domain and spectral-domain optical coherence tomography

Author keywords

Cataract; Glaucoma; Optical coherence tomography; Pupil; Retinal nerve fibre layer

Indexed keywords

ADULT; AGED; ARTICLE; CATARACT; CLINICAL ARTICLE; FEMALE; HUMAN; INTERMETHOD COMPARISON; MALE; MEASUREMENT; MYDRIASIS; OPTICAL COHERENCE TOMOGRAPHY; PROSPECTIVE STUDY; PUPIL; REPRODUCIBILITY; RETINA; RETINA NERVE FIBER LAYER; THICKNESS;

EID: 79954495201     PISSN: 14426404     EISSN: 14429071     Source Type: Journal    
DOI: 10.1111/j.1442-9071.2010.02460.x     Document Type: Article
Times cited : (39)

References (24)
  • 1
    • 0033589732 scopus 로고    scopus 로고
    • Glaucoma
    • Coleman AL. Glaucoma. Lancet 1999; 354: 1803-10.
    • (1999) Lancet , vol.354 , pp. 1803-1810
    • Coleman, A.L.1
  • 3
    • 34748820739 scopus 로고    scopus 로고
    • Optic nerve head and retinal nerve fibre layer analysis. A report by the American Academy of Ophthalmology
    • Lin SC, Singh K, Jampel HD etal. Optic nerve head and retinal nerve fibre layer analysis. A report by the American Academy of Ophthalmology. Ophthalmology 2007; 114: 1937-49.
    • (2007) Ophthalmology , vol.114 , pp. 1937-1949
    • Lin, S.C.1    Singh, K.2    Jampel, H.D.3
  • 4
    • 72049094509 scopus 로고    scopus 로고
    • Spectral-domain optical coherence tomography: a comparison of modern high-resolution retinal imaging systems
    • Kiernan DF, Mieler WF, Hariprasad SM. Spectral-domain optical coherence tomography: a comparison of modern high-resolution retinal imaging systems. Am J Ophthalmol 2010; 149: 18-31.
    • (2010) Am J Ophthalmol , vol.149 , pp. 18-31
    • Kiernan, D.F.1    Mieler, W.F.2    Hariprasad, S.M.3
  • 5
    • 67649336413 scopus 로고    scopus 로고
    • Retinal nerve fibre layer imaging with spectral-domain optical coherence tomography: a variability and diagnostic performance study
    • Leung CK, Cheung CY, Weinreb RN etal. Retinal nerve fibre layer imaging with spectral-domain optical coherence tomography: a variability and diagnostic performance study. Ophthalmology 2009; 116: 1257-63.
    • (2009) Ophthalmology , vol.116 , pp. 1257-1263
    • Leung, C.K.1    Cheung, C.Y.2    Weinreb, R.N.3
  • 6
    • 70649094280 scopus 로고    scopus 로고
    • Sensitivity and specificity of time-domain versus spectral-domain optical coherence tomography in diagnosing early to moderate glaucoma
    • Chang RT, Knight OJ, Feuer WJ, Budenz DL. Sensitivity and specificity of time-domain versus spectral-domain optical coherence tomography in diagnosing early to moderate glaucoma. Ophthalmology 2009; 116: 2294-9.
    • (2009) Ophthalmology , vol.116 , pp. 2294-2299
    • Chang, R.T.1    Knight, O.J.2    Feuer, W.J.3    Budenz, D.L.4
  • 7
    • 77449084640 scopus 로고    scopus 로고
    • Comparison of Cirrus OCT and Stratus OCT on the ability to detect localized retinal nerve fibre layer defects in preperimetric glaucoma
    • Jeoung JW, Park KH. Comparison of Cirrus OCT and Stratus OCT on the ability to detect localized retinal nerve fibre layer defects in preperimetric glaucoma. Invest Ophthalmol Vis Sci 2010; 51: 938-45.
    • (2010) Invest Ophthalmol Vis Sci , vol.51 , pp. 938-945
    • Jeoung, J.W.1    Park, K.H.2
  • 8
    • 67649311848 scopus 로고    scopus 로고
    • Comparison of retinal nerve fibre layer measurements using time domain and spectral domain optical coherent tomography
    • Knight OR, Chang RT, Feuer WJ, Budenz DL. Comparison of retinal nerve fibre layer measurements using time domain and spectral domain optical coherent tomography. Ophthalmology 2009; 116: 1271-7.
    • (2009) Ophthalmology , vol.116 , pp. 1271-1277
    • Knight, O.R.1    Chang, R.T.2    Feuer, W.J.3    Budenz, D.L.4
  • 9
    • 67649311613 scopus 로고    scopus 로고
    • Comparison of retinal nerve fibre layer thickness measured by cirrus HD and stratus optical coherence tomography
    • Sung KR, Kim DY, Park SB, Kook MS. Comparison of retinal nerve fibre layer thickness measured by cirrus HD and stratus optical coherence tomography. Ophthalmology 2009; 116: 1264-70.
    • (2009) Ophthalmology , vol.116 , pp. 1264-1270
    • Sung, K.R.1    Kim, D.Y.2    Park, S.B.3    Kook, M.S.4
  • 10
    • 0036822851 scopus 로고    scopus 로고
    • Reduction of intraocular pressure and glaucoma progression: results from the Early Manifest Glaucoma Trial
    • Heijl A, Leske MC, Bengtsson B etal. Reduction of intraocular pressure and glaucoma progression: results from the Early Manifest Glaucoma Trial. Arch Ophthalmol 2002; 120: 1268-79.
    • (2002) Arch Ophthalmol , vol.120 , pp. 1268-1279
    • Heijl, A.1    Leske, M.C.2    Bengtsson, B.3
  • 11
    • 33746426603 scopus 로고    scopus 로고
    • Influence of pupil size and cataract on retinal nerve fibre layer thickness measurements by Stratus OCT
    • Savini G, Zanini M, Barboni P. Influence of pupil size and cataract on retinal nerve fibre layer thickness measurements by Stratus OCT. J Glaucoma 2006; 15: 336-40.
    • (2006) J Glaucoma , vol.15 , pp. 336-340
    • Savini, G.1    Zanini, M.2    Barboni, P.3
  • 12
    • 0034806333 scopus 로고    scopus 로고
    • Effects of cataract extraction with intraocular lens placement on scanning laser polarimetry of the peripapillary nerve fibre layer
    • Park RJ, Chen PP, Karyampudi P, Mills RP, Harrison DA, Kim J. Effects of cataract extraction with intraocular lens placement on scanning laser polarimetry of the peripapillary nerve fibre layer. Am J Ophthalmol 2001; 132: 507-11.
    • (2001) Am J Ophthalmol , vol.132 , pp. 507-511
    • Park, R.J.1    Chen, P.P.2    Karyampudi, P.3    Mills, R.P.4    Harrison, D.A.5    Kim, J.6
  • 13
    • 1342303850 scopus 로고    scopus 로고
    • Effect of cataract extraction and intraocular lens implantation on nerve fibre layer thickness measurements by scanning laser polarimeter (GDx) in glaucoma patients
    • Gazzard G, Foster PJ, Devereux JG etal. Effect of cataract extraction and intraocular lens implantation on nerve fibre layer thickness measurements by scanning laser polarimeter (GDx) in glaucoma patients. Eye (Lond) 2004; 18: 163-8.
    • (2004) Eye (Lond) , vol.18 , pp. 163-168
    • Gazzard, G.1    Foster, P.J.2    Devereux, J.G.3
  • 14
    • 1642499187 scopus 로고    scopus 로고
    • Effect of pupillary dilation on retinal nerve fibre layer thickness measurements using optical coherence tomography
    • Zafar S, Gurses-Ozden R, Vessani R etal. Effect of pupillary dilation on retinal nerve fibre layer thickness measurements using optical coherence tomography. J Glaucoma 2004; 13: 34-7.
    • (2004) J Glaucoma , vol.13 , pp. 34-37
    • Zafar, S.1    Gurses-Ozden, R.2    Vessani, R.3
  • 15
    • 0030789103 scopus 로고    scopus 로고
    • Effect of cataract and pupil size on image quality with confocal scanning laser ophthalmoscopy
    • Zangwill L, Irak I, Berry CC etal. Effect of cataract and pupil size on image quality with confocal scanning laser ophthalmoscopy. Arch Ophthalmol 1997; 115: 983-90.
    • (1997) Arch Ophthalmol , vol.115 , pp. 983-990
    • Zangwill, L.1    Irak, I.2    Berry, C.C.3
  • 16
  • 17
    • 0037254479 scopus 로고    scopus 로고
    • Clinical application of the Lens Opacities Classification System III in the performance of phacoemulsification
    • Davidson JA, Chylack LT. Clinical application of the Lens Opacities Classification System III in the performance of phacoemulsification. J Cataract Refract Surg 2003; 29: 138-45.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 138-145
    • Davidson, J.A.1    Chylack, L.T.2
  • 18
    • 75749103045 scopus 로고    scopus 로고
    • Evaluation of retinal nerve fibre layer progression in glaucoma: a study on optical coherence tomography guided progression analysis
    • Leung CK, Cheung CY, Weinreb RN etal. Evaluation of retinal nerve fibre layer progression in glaucoma: a study on optical coherence tomography guided progression analysis. Invest Ophthalmol Vis Sci 2010; 51: 217-22.
    • (2010) Invest Ophthalmol Vis Sci , vol.51 , pp. 217-222
    • Leung, C.K.1    Cheung, C.Y.2    Weinreb, R.N.3
  • 19
    • 20144389022 scopus 로고    scopus 로고
    • Optical coherence tomography longitudinal evaluation of retinal nerve fibre layer thickness in glaucoma
    • Wollstein G, Schuman JS, Price LL etal. Optical coherence tomography longitudinal evaluation of retinal nerve fibre layer thickness in glaucoma. Arch Ophthalmol 2005; 123: 464-70.
    • (2005) Arch Ophthalmol , vol.123 , pp. 464-470
    • Wollstein, G.1    Schuman, J.S.2    Price, L.L.3
  • 20
    • 34547201948 scopus 로고    scopus 로고
    • Factors associated with variability in retinal nerve fibre layer thickness measurements obtained by optical coherence tomography
    • Wu Z, Vazeen M, Varma R etal. Factors associated with variability in retinal nerve fibre layer thickness measurements obtained by optical coherence tomography. Ophthalmology 2007; 114: 1505-12.
    • (2007) Ophthalmology , vol.114 , pp. 1505-1512
    • Wu, Z.1    Vazeen, M.2    Varma, R.3
  • 21
    • 65649122277 scopus 로고    scopus 로고
    • Signal strength is an important determinant of accuracy of nerve fibre layer thickness measurement by optical coherence tomography
    • Wu Z, Huang J, Dustin L, Sadda SR. Signal strength is an important determinant of accuracy of nerve fibre layer thickness measurement by optical coherence tomography. J Glaucoma 2009; 18: 213-16.
    • (2009) J Glaucoma , vol.18 , pp. 213-216
    • Wu, Z.1    Huang, J.2    Dustin, L.3    Sadda, S.R.4
  • 22
    • 48149085695 scopus 로고    scopus 로고
    • Relationship between retinal nerve fibre layer measurement and signal strength in optical coherence tomography
    • Cheung CY, Leung CK, Lin D, Pang CP, Lam DS. Relationship between retinal nerve fibre layer measurement and signal strength in optical coherence tomography. Ophthalmology 2008; 115: 1347-51.
    • (2008) Ophthalmology , vol.115 , pp. 1347-1351
    • Cheung, C.Y.1    Leung, C.K.2    Lin, D.3    Pang, C.P.4    Lam, D.S.5
  • 23
    • 36749103793 scopus 로고    scopus 로고
    • Effect of pupillary dilatation on glaucoma assessments using optical coherence tomography
    • Smith M, Frost A, Graham CM, Shaw S. Effect of pupillary dilatation on glaucoma assessments using optical coherence tomography. Br J Ophthalmol 2007; 91: 1686-90.
    • (2007) Br J Ophthalmol , vol.91 , pp. 1686-1690
    • Smith, M.1    Frost, A.2    Graham, C.M.3    Shaw, S.4
  • 24
    • 0026254046 scopus 로고
    • Optical coherence tomography
    • Huang D, Swanson EA, Lin CP etal. Optical coherence tomography. Science 1991; 254: 1178-81.
    • (1991) Science , vol.254 , pp. 1178-1181
    • Huang, D.1    Swanson, E.A.2    Lin, C.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.