메뉴 건너뛰기




Volumn 6, Issue 4, 2011, Pages

Evaluation of microwave steam bags for the decontamination of filtering facepiece respirators

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CLINICAL EFFECTIVENESS; CONTROLLED STUDY; FACE MASK; FILTER DESIGN; FILTRATION; HYDROPHILICITY; INSTRUMENT STERILIZATION; INSTRUMENT VALIDATION; LONG TERM EXPOSURE; MATERIALS TESTING; MICROWAVE RADIATION; MS2 VIRUS; VENTILATOR; VIRUS INACTIVATION; WATER ABSORPTION; WATER VAPOR; EVALUATION; INSTRUMENTATION; WASTE MANAGEMENT;

EID: 79954487342     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0018585     Document Type: Article
Times cited : (71)

References (26)
  • 1
    • 33749431344 scopus 로고    scopus 로고
    • D.C.: National Academies Press, Institute of Medicine (U.S) Committee on the Development of Reusable Facemasks for Use During an Influenza Pandemic
    • Institute of Medicine (U.S) Committee on the Development of Reusable Facemasks for Use During an Influenza Pandemic (2006) Reusability of facemasks during an influenza pandemic: facing the flu. Washington, eds. D.C.: National Academies Press.
    • (2006) Reusability of facemasks during an influenza pandemic: facing the flu
  • 2
    • 71249112435 scopus 로고    scopus 로고
    • Proposed guidance on workplace stockpiling of respirators and facemasks for pandemic influenza
    • Occupational Safety & Health Administration, Available:. Accessed 2009 Oct 5
    • Occupational Safety & Health Administration (2008) Proposed guidance on workplace stockpiling of respirators and facemasks for pandemic influenza. Available: http://www.osha.gov/dsg/guidance/proposedGuidanceStockpilingRespirator.pdf. Accessed 2009 Oct 5.
    • (2008)
  • 3
    • 62149092888 scopus 로고    scopus 로고
    • Development of a test system to apply virus-containing particles to filtering facepiece respirators for the evaluation of decontamination procedures
    • Fisher E, Rengasamy S, Viscusi D, Vo E, Shaffer R, (2009) Development of a test system to apply virus-containing particles to filtering facepiece respirators for the evaluation of decontamination procedures. Appl Environ Microbiol 75: 1500-1507.
    • (2009) Appl Environ Microbiol , vol.75 , pp. 1500-1507
    • Fisher, E.1    Rengasamy, S.2    Viscusi, D.3    Vo, E.4    Shaffer, R.5
  • 4
    • 78650131068 scopus 로고    scopus 로고
    • A Method to Determine the Available UV-C Dose for the Decontamination of Filtering Facepiece Respirators
    • Fisher E, Shaffer R, (2011) A Method to Determine the Available UV-C Dose for the Decontamination of Filtering Facepiece Respirators. J Appl Microbiol 110: 287-295.
    • (2011) J Appl Microbiol , vol.110 , pp. 287-295
    • Fisher, E.1    Shaffer, R.2
  • 5
    • 79954546017 scopus 로고    scopus 로고
    • The effect of soil accumulation on multiple decontamination processing of N95 filtering facepiece respirator coupons using physical methods
    • Fisher E, Williams J, Shaffer R, (2010) The effect of soil accumulation on multiple decontamination processing of N95 filtering facepiece respirator coupons using physical methods. JISRP 27: 16-26.
    • (2010) JISRP , vol.27 , pp. 16-26
    • Fisher, E.1    Williams, J.2    Shaffer, R.3
  • 6
    • 79551533152 scopus 로고    scopus 로고
    • A pandemic influenza preparedness study: use of energetic methods to decontaminate filtering facepiece respirators contaminated with H1N1 aerosols and droplets
    • Heimbuch BK, Wallace WH, Kinney KR, Lumley AE, Wu CY, et al. (2011) A pandemic influenza preparedness study: use of energetic methods to decontaminate filtering facepiece respirators contaminated with H1N1 aerosols and droplets. Am J Infect Control 39: e1-9.
    • (2011) Am J Infect Control , vol.39
    • Heimbuch, B.K.1    Wallace, W.H.2    Kinney, K.R.3    Lumley, A.E.4    Wu, C.Y.5
  • 7
    • 74449089943 scopus 로고    scopus 로고
    • Evaluation of the survivability of MS2 viral aerosols deposited on filtering face piece respirator samples incorporating antimicrobial technologies
    • Rengasamy S, Fisher E, Shaffer RE, (2010) Evaluation of the survivability of MS2 viral aerosols deposited on filtering face piece respirator samples incorporating antimicrobial technologies. Am J Infect Control 38: 9-17.
    • (2010) Am J Infect Control , vol.38 , pp. 9-17
    • Rengasamy, S.1    Fisher, E.2    Shaffer, R.E.3
  • 8
    • 72649104624 scopus 로고    scopus 로고
    • Evaluation of five decontamination methods for filtering facepiece respirators
    • Viscusi DJ, Bergman MS, Eimer BC, Shaffer RE, (2009) Evaluation of five decontamination methods for filtering facepiece respirators. Ann Occup Hyg 53: 815-827.
    • (2009) Ann Occup Hyg , vol.53 , pp. 815-827
    • Viscusi, D.J.1    Bergman, M.S.2    Eimer, B.C.3    Shaffer, R.E.4
  • 9
    • 62149104178 scopus 로고    scopus 로고
    • Effect of decontamination on the filtration efficiency of two filtering facepiece respirator models
    • Viscusi DJ, King WP, Shaffer RE, (2007) Effect of decontamination on the filtration efficiency of two filtering facepiece respirator models. JISRP 24: 93-107.
    • (2007) JISRP , vol.24 , pp. 93-107
    • Viscusi, D.J.1    King, W.P.2    Shaffer, R.E.3
  • 10
    • 72949123047 scopus 로고    scopus 로고
    • Development of a test system to evaluate procedures for decontamination of respirators containing viral droplets
    • Vo E, Rengasamy S, Shaffer R, (2009) Development of a test system to evaluate procedures for decontamination of respirators containing viral droplets. Appl Environ Microbiol 75: 7303-7309.
    • (2009) Appl Environ Microbiol , vol.75 , pp. 7303-7309
    • Vo, E.1    Rengasamy, S.2    Shaffer, R.3
  • 11
    • 77957012668 scopus 로고    scopus 로고
    • Analysis of Residual Chemicals on Filtering Facepiece Respirators After Decontamination
    • Salter WB, Kinney K, Wallace WH, Lumley AE, Heimbuch BK, et al. (2010) Analysis of Residual Chemicals on Filtering Facepiece Respirators After Decontamination. J Occup Env Hyg 7: 437-445.
    • (2010) J Occup Env Hyg , vol.7 , pp. 437-445
    • Salter, W.B.1    Kinney, K.2    Wallace, W.H.3    Lumley, A.E.4    Heimbuch, B.K.5
  • 12
    • 78649764119 scopus 로고    scopus 로고
    • Evaluation of Multiple (3-Cycle) Decontamination Processing for Filtering Facepiece Respirators
    • Bergman MS, Viscusi DJ, Heimbuch BK, Wander JD, Sambol AR, et al. (2010) Evaluation of Multiple (3-Cycle) Decontamination Processing for Filtering Facepiece Respirators. JEFF 4: 33-41.
    • (2010) JEFF , vol.4 , pp. 33-41
    • Bergman, M.S.1    Viscusi, D.J.2    Heimbuch, B.K.3    Wander, J.D.4    Sambol, A.R.5
  • 13
    • 62149140344 scopus 로고    scopus 로고
    • Decontamination of filtration media for respiration
    • United States. Pub. No. US 2008/0085210 A1, US Patent Application Publication. Griesbach HC, (GA, US), Arehart, Kelly (Roswell, GA, US), Johnson, David Wayne (Alpharetta, GA, US), Macdonald, Gavin (Decatur, GA, US)
    • US Patent Application Publication. Griesbach HC, (GA, US), Arehart, Kelly (Roswell, GA, US), Johnson, David Wayne (Alpharetta, GA, US), Macdonald, Gavin (Decatur, GA, US) (2008) Decontamination of filtration media for respiration. United States. Pub. No. US 2008/0085210 A1.
    • (2008)
  • 14
    • 33748760894 scopus 로고    scopus 로고
    • Modified N95 mask delivers high inspired oxygen concentrations while effectively filtering aerosolized microparticles
    • Mardimae A, Slessarev M, Han J, Sasano H, Sasano N, et al. (2006) Modified N95 mask delivers high inspired oxygen concentrations while effectively filtering aerosolized microparticles. Ann Emergency Med 48: 391-399.
    • (2006) Ann Emergency Med , vol.48 , pp. 391-399
    • Mardimae, A.1    Slessarev, M.2    Han, J.3    Sasano, H.4    Sasano, N.5
  • 15
    • 34250808965 scopus 로고    scopus 로고
    • Disrupting the transmission of influenza a: face masks and ultraviolet light as control measures
    • Weiss MM, Weiss PD, Weiss DE, Weiss JB, (2007) Disrupting the transmission of influenza a: face masks and ultraviolet light as control measures. Am J Public Health 97 (Suppl 1): S32-37.
    • (2007) Am J Public Health , vol.97 , Issue.SUPPL. 1
    • Weiss, M.M.1    Weiss, P.D.2    Weiss, D.E.3    Weiss, J.B.4
  • 16
    • 66149120302 scopus 로고    scopus 로고
    • Evaluation of the filtration performance of 21 N95 filtering face piece respirators after prolonged storage
    • Viscusi DJ, Bergman M, Sinkule E, Shaffer RE, (2009) Evaluation of the filtration performance of 21 N95 filtering face piece respirators after prolonged storage. Am J Infect Control 37: 381-386.
    • (2009) Am J Infect Control , vol.37 , pp. 381-386
    • Viscusi, D.J.1    Bergman, M.2    Sinkule, E.3    Shaffer, R.E.4
  • 17
    • 0003820222 scopus 로고    scopus 로고
    • Method 1602 Male-specific (F+) and Somatic Coliphage in Water by Single Agar Layer (SAL) Procedure
    • United States Environmental Protection Agency, Office of Water., Washington, D.C., EPA 821-R-01-029,
    • United States Environmental Protection Agency, Office of Water. (2001) Method 1602 Male-specific (F+) and Somatic Coliphage in Water by Single Agar Layer (SAL) Procedure. Washington, D.C. EPA 821-R-01-029,.
    • (2001)
  • 18
    • 79551531798 scopus 로고    scopus 로고
    • ASTM E2721-2010: standard test method of evaluating of the effectiveness of decontamination procedures for surfaces when challenged with droplets containing human pathogenic viruses
    • American Society for Testing and Materials (ASTM) International, West Conshohocken (PA), American Society for Testing and Materials International
    • American Society for Testing and Materials (ASTM) International (2010) ASTM E2721-2010: standard test method of evaluating of the effectiveness of decontamination procedures for surfaces when challenged with droplets containing human pathogenic viruses. West Conshohocken (PA) American Society for Testing and Materials International.
    • (2010)
  • 19
    • 77955841192 scopus 로고    scopus 로고
    • Method for contamination of filtering facepiece respirators by deposition of MS2 viral aerosols
    • Woo M-H, Hsu Y-M, Wu C-Y, Heimbuch B, Wander J, (2010) Method for contamination of filtering facepiece respirators by deposition of MS2 viral aerosols. J Aerosol Sci 41: 944-952.
    • (2010) J Aerosol Sci , vol.41 , pp. 944-952
    • Woo, M.-H.1    Hsu, Y.-M.2    Wu, C.-Y.3    Heimbuch, B.4    Wander, J.5
  • 20
    • 0037717068 scopus 로고    scopus 로고
    • Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008
    • Healthcare Infection Control Practices Advisory Committee, Available:. Accessed 2011 Feb 14
    • Rutala WA, Weber DJ, Healthcare Infection Control Practices Advisory Committee (2008) Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008. Available: http://www.cdc.gov/hicpac/pdf/guidelines/Disinfection_Nov_2008.pdf. Accessed 2011 Feb 14.
    • (2008)
    • Rutala, W.A.1    Weber, D.J.2
  • 21
    • 79954553431 scopus 로고    scopus 로고
    • Impact of Three Biological Decontamination Methods on Filtering Facepiece Respirator Fit, Smell, Comfort, and Donning Ease. National Personal Protective Technology Program Stakeholder Meeting, Pittsburgh, PA
    • Available:. Accessed 2011 Feb 14
    • Viscusi DJ, Bergman MS, Novak DA, Faulkner KA, Palmiero AJ, et al. (2010) Impact of Three Biological Decontamination Methods on Filtering Facepiece Respirator Fit, Smell, Comfort, and Donning Ease. National Personal Protective Technology Program Stakeholder Meeting, Pittsburgh, PA. Available: http://www.archive.org/download/PptProgramStakeholderMeetingPostersMarch2-32010/42InhalViscusi.pdf. Accessed 2011 Feb 14.
    • (2010)
    • Viscusi, D.J.1    Bergman, M.S.2    Novak, D.A.3    Faulkner, K.A.4    Palmiero, A.J.5
  • 22
    • 77955900463 scopus 로고    scopus 로고
    • Effect of Exhaled Moisture on Breathing Resistance of N95 Filtering Facepiece Respirators
    • Roberge RJ, Bayer E, Powell JB, Coca A, Roberge MR, et al. (2010) Effect of Exhaled Moisture on Breathing Resistance of N95 Filtering Facepiece Respirators. Ann Occup Hyg 54: 671-677.
    • (2010) Ann Occup Hyg , vol.54 , pp. 671-677
    • Roberge, R.J.1    Bayer, E.2    Powell, J.B.3    Coca, A.4    Roberge, M.R.5
  • 23
    • 79954495692 scopus 로고    scopus 로고
    • Medical Device User Fee and Modernization Act of 2002, validation data in premarket notification submissions (510(k)s) for reprocessed single use medical devices
    • United States Department of Health and Human Services, Food and Drug Administration, Centers for Devices and Radiological Health Evaluation, Office of Device Evaluation, Available:. Accessed 2011 Feb 14
    • United States Department of Health and Human Services, Food and Drug Administration, Centers for Devices and Radiological Health Evaluation, Office of Device Evaluation (2006) Medical Device User Fee and Modernization Act of 2002, validation data in premarket notification submissions (510(k)s) for reprocessed single use medical devices. Available: http://www.fda.gov/downloads/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/ucm071441.pdf. Accessed 2011 Feb 14.
    • (2006)
  • 24
    • 77649194380 scopus 로고    scopus 로고
    • Reprocessed single-use medical devices
    • United States Government Accountability Office, Available:. Accessed 2011 Feb 14,GAO-08-147
    • United States Government Accountability Office (2008) Reprocessed single-use medical devices. GAO-08-147. Available: http://www.gao.gov/new.items/d08147.pdf. Accessed 2011 Feb 14.
    • (2008)
  • 25
    • 0037751175 scopus 로고    scopus 로고
    • TB Respiratory protection program in health care facilities Administrator's guide
    • CDC, Available:. Accessed 2011 Feb 14
    • CDC, (1999) TB Respiratory protection program in health care facilities Administrator's guide. Available: http://www.cdc.gov/niosh/docs/99-143/. Accessed 2011 Feb 14.
    • (1999)
  • 26
    • 77955293840 scopus 로고    scopus 로고
    • Questions and Answers Regarding Respiratory Protection For Preventing 2009 H1N1 Influenza Among Healthcare Personnel
    • CDC, Available:. Accessed 2011 Feb 14
    • CDC (2010) Questions and Answers Regarding Respiratory Protection For Preventing 2009 H1N1 Influenza Among Healthcare Personnel. Available: http://www.cdc.gov/h1n1flu/guidelines_infection_control_qa.htm. Accessed 2011 Feb 14.
    • (2010)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.