메뉴 건너뛰기




Volumn 11, Issue 4, 2011, Pages 295-302

Cranial facet joint violations by percutaneously placed pedicle screws adjacent to a minimally invasive lumbar spinal fusion

Author keywords

Cranial facet joint violation; Lumbar spine fusion; Minimally invasive; Percutaneous pedicle screw

Indexed keywords

ADULT; AGED; ARTICLE; BODY MASS; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; HUMAN; INCIDENCE; JOINT INJURY; LOGISTIC REGRESSION ANALYSIS; LUMBAR SPINE; MAJOR CLINICAL STUDY; MALE; MINIMALLY INVASIVE SURGERY; PEDICLE SCREW; POSTOPERATIVE CARE; PRIORITY JOURNAL; PROSPECTIVE STUDY; RETROSPECTIVE STUDY; RISK; SPINE FUSION; SURGEON; ZYGAPOPHYSEAL JOINT;

EID: 79953887403     PISSN: 15299430     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.spinee.2011.02.007     Document Type: Article
Times cited : (76)

References (14)
  • 1
    • 0028837713 scopus 로고
    • Postfusion instability at the adjacent segments after rigid pedicle screw fixation for degenerative lumbar spinal disorders
    • Aota Y, Kumano K, Hirabayashi S. Postfusion instability at the adjacent segments after rigid pedicle screw fixation for degenerative lumbar spinal disorders. J Spinal Disord 1995;8:464-73.
    • (1995) J Spinal Disord , vol.8 , pp. 464-473
    • Aota, Y.1    Kumano, K.2    Hirabayashi, S.3
  • 2
    • 56349123669 scopus 로고    scopus 로고
    • Technical factors related to the incidence of adjacent superior segment facet joint violation after transpedicular instrumentation in the lumbar spine
    • Chen Z, Zhao J, Xu H, et al. Technical factors related to the incidence of adjacent superior segment facet joint violation after transpedicular instrumentation in the lumbar spine. Eur Spine J 2008;17:1476-80.
    • (2008) Eur Spine J , vol.17 , pp. 1476-1480
    • Chen, Z.1    Zhao, J.2    Xu, H.3
  • 3
    • 33750296573 scopus 로고    scopus 로고
    • Computed tomography evaluation of superior-segment facet-joint violation after pedicle instrumentation of the lumbar spine with a midline surgical approach
    • DOI 10.1097/01.brs.0000240691.35707.e8, PII 0000763220061015000020
    • Moshirfar A, Jenis LG, Spector LR, et al. Computed tomography evaluation of superior-segment facet-joint violation after pedicle instrumentation of the lumbar spine with a midline surgical approach. Spine 2006;31:2624-9. (Pubitemid 44632249)
    • (2006) Spine , vol.31 , Issue.22 , pp. 2624-2629
    • Moshirfar, A.1    Jenis, L.G.2    Spector, L.R.3    Burke, P.J.4    Losina, E.5    Katz, J.N.6    Rand, F.F.7    Tromanhauser, S.G.8    Banco, R.J.9
  • 4
    • 0037318275 scopus 로고    scopus 로고
    • Radiologic evaluation of adjacent superior segment facet joint violation following transpedicular instrumentation of the lumbar spine
    • DOI 10.1097/00007632-200302010-00013
    • Shah RR, Muhammed S, Saifuddin A, Taylor BA. Radiologic evaluation of adjacent superior segment facet joint violation following transpedicular instrumentation of the lumbar spine. Spine 2003;28:272-5. (Pubitemid 36177192)
    • (2003) Spine , vol.28 , Issue.3 , pp. 272-275
    • Shah, R.R.1    Mohammed, S.2    Saifuddin, A.3    Taylor, B.A.4
  • 6
    • 4444329571 scopus 로고    scopus 로고
    • Adjacent segment disease after lumbar or lumbosacral fusion: Review of the literature
    • DOI 10.1097/01.brs.0000137069.88904.03
    • Park P, Garton HJ, Gala VC, et al. Adjacent segment disease after lumbar or lumbosacral fusion: review of the literature. Spine 2004;29:1938-44. (Pubitemid 39181056)
    • (2004) Spine , vol.29 , Issue.17 , pp. 1938-1944
    • Park, P.1    Garton, H.J.2    Gala, V.C.3    Hoff, J.T.4    McGillicuddy, J.E.5
  • 7
    • 0036288337 scopus 로고    scopus 로고
    • Percutaneous pedicle screw fixation of the lumbar spine: Preliminary clinical results
    • Foley KT, Gupta SK. Percutaneous pedicle screw fixation of the lumbar spine: preliminary clinical results. J Neurosurg Spine 2002;97:7-12. (Pubitemid 34686594)
    • (2002) Journal of Neurosurgery , vol.97 , Issue.1 SUPPL. , pp. 7-12
    • Foley, K.T.1    Gupta, S.K.2
  • 8
    • 0042067885 scopus 로고    scopus 로고
    • Minimally invasive lumbar fusion
    • Foley KT, Holly LT, Schwender JD. Minimally invasive lumbar fusion. Spine 2003;15(Suppl):26-35.
    • (2003) Spine , vol.15 , Issue.SUPPL. , pp. 26-35
    • Foley, K.T.1    Holly, L.T.2    Schwender, J.D.3
  • 9
    • 33947134920 scopus 로고    scopus 로고
    • Comparison of one-level posterior lumbar interbody fusion performed with a minimally invasive approach or a traditional open approach
    • DOI 10.1097/01.brs.0000256473.49791.f4, PII 0000763220070301000007
    • Park Y, Ha JW. Comparison of one-level posterior lumbar interbody fusion performed with a minimally invasive approach or a traditional open approach. Spine 2007;32:537-43. (Pubitemid 46398919)
    • (2007) Spine , vol.32 , Issue.5 , pp. 537-543
    • Park, Y.1    Ha, J.W.2
  • 10
    • 33646596935 scopus 로고    scopus 로고
    • Placement of percutaneous pedicle screws without imaging guidance
    • Powers CJ, Podichetty VK, Isaacs RE. Placement of percutaneous pedicle screws without imaging guidance. Neurosurg Focus 2006;20:E3.
    • (2006) Neurosurg Focus , vol.20
    • Powers, C.J.1    Podichetty, V.K.2    Isaacs, R.E.3
  • 11
    • 34147196905 scopus 로고    scopus 로고
    • Percutaneous transforaminal lumbar interbody fusion for the treatment of degenerative lumbar instability
    • Scheufler KM, Dohmen H, Vougioukas VI. Percutaneous transforaminal lumbar interbody fusion for the treatment of degenerative lumbar instability. Neurosurgery 2007;60(4 Suppl):203-12.
    • (2007) Neurosurgery , vol.60 , Issue.4 SUPPL. , pp. 203-212
    • Scheufler, K.M.1    Dohmen, H.2    Vougioukas, V.I.3
  • 12
    • 21344451136 scopus 로고    scopus 로고
    • Minimally invasive transforaminal lumbar interbody fusion (TLIF): Technical feasibility and initial results
    • Schwender J, Holly LT, Rouben DP, Foley KT. Minimally invasive transforaminal lumbar interbody fusion (TLIF): technical feasibility and initial results. J Spinal Disord Tech 2005;18(1 Suppl):1-6.
    • (2005) J Spinal Disord Tech , vol.18 , Issue.1 SUPPL. , pp. 1-6
    • Schwender, J.1    Holly, L.T.2    Rouben, D.P.3    Foley, K.T.4
  • 13
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977;33:159-74. (Pubitemid 8054849)
    • (1977) Biometrics , vol.33 , Issue.1 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 14
    • 0042568676 scopus 로고    scopus 로고
    • Intraoperative spinal navigation
    • Holly LT, Foley KT. Intraoperative spinal navigation. Spine 2003;28:S54-61.
    • (2003) Spine , vol.28
    • Holly, L.T.1    Foley, K.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.