메뉴 건너뛰기




Volumn 35, Issue 3-4, 2011, Pages 185-190

Portable cost-effective EEG data acquisition system

Author keywords

Cognition; Driven right leg; EEG amplifier; HPF; LPF; ORCAD design

Indexed keywords

COGNITION; DRIVEN-RIGHT-LEG; EEG AMPLIFIER; HPF; LPF; ORCAD DESIGN;

EID: 79953871012     PISSN: 03091902     EISSN: 1464522X     Source Type: Journal    
DOI: 10.3109/03091902.2011.560701     Document Type: Article
Times cited : (3)

References (13)
  • 1
    • 0037794020 scopus 로고    scopus 로고
    • The emergence of the menopause in India
    • Sengupta, A., 2003, The emergence of the menopause in India. Climacteric, 6, 92-95. (Pubitemid 36714080)
    • (2003) Climacteric , vol.6 , Issue.2 , pp. 92-95
    • Sengupta, A.1
  • 4
    • 0034306447 scopus 로고    scopus 로고
    • Structural and functional brain development and its relation to cognitive development
    • Casey, J., Giedd, J. N. and Thomas, K. M., 2000, Structural and functional brain development and its relation to cognitive development. Biological Psychology, 54, 241-257.
    • (2000) Biological Psychology , vol.54 , pp. 241-257
    • Casey, J.1    Giedd, J.N.2    Thomas, K.M.3
  • 5
    • 0034856883 scopus 로고    scopus 로고
    • Testosterone supplementation in older men: A rational idea whose time has not yet come
    • Bhasin, S. and Buckwalter, J. G., 2001, Testosterone supplementation in older men: a rational idea whose time has not yet come. Journal of Andrology, 22, 718-731. (Pubitemid 32781257)
    • (2001) Journal of Andrology , vol.22 , Issue.5 , pp. 718-731
    • Bhasin, S.1    Buckwalter, J.G.2
  • 6
    • 0021645224 scopus 로고
    • Reducing motion artifacts and interference in biopotential recording
    • Webster, J. G., 1984, Reducing motion artifacts and interference in biopotential recording. IEEETransactions on Biomedical Engineering, 31, 823-826.
    • (1984) IEEETransactions on Biomedical Engineering , vol.31 , pp. 823-826
    • Webster, J.G.1
  • 8
    • 31544470380 scopus 로고    scopus 로고
    • A pseudodifferential amplifier for bioelectric events with DC-offset compensation using two-wired amplifying electrodes
    • DOI 10.1109/TBME.2005.862531
    • Degen, T. and Jäckel, H., 2006, Pseudodifferential amplifier for bioelectric events, with DC-offset compensation using two-wired amplifying electrodes. IEEE Transaction on Biomedical Engineering, 53, 300-310. (Pubitemid 43162418)
    • (2006) IEEE Transactions on Biomedical Engineering , vol.53 , Issue.2 , pp. 300-310
    • Degen, T.1    Jackel, H.2
  • 9
    • 33644866861 scopus 로고    scopus 로고
    • Miniature neurologgers for flying pigeons: Multichannel EEG and action and field potentials in combination with GPS recording
    • DOI 10.1152/jn.00879.2005
    • Vyssotski, A. L., Serkov, A. N., Itskov, P. M., Dell'Omo, G., Latanov, A. V., Wolfer, D. P. and Lipp, H. P., 2006, Miniature neurologgers for flying pigeons: Multichannel EEG and action and field potentials in combination with GPS recording. Journal of Neurophysiology, 95, 1263-1273. (Pubitemid 44699121)
    • (2006) Journal of Neurophysiology , vol.95 , Issue.2 , pp. 1263-1273
    • Vyssotski, A.L.1    Serkov, A.N.2    Itskov, P.M.3    Dell'Omo, G.4    Latanov, A.V.5    Wolfer, D.P.6    Lipp, H.-P.7
  • 12
    • 11144326302 scopus 로고    scopus 로고
    • Reduction of power line interference using active electrodes and a driven-right-leg circuit in electroencephalographic recording with a minimum number of electrodes
    • Conference Proceedings - 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2004
    • Nonclercq, A. and Mathys, P., 2004, Reduction of power line interference using active electrodes and a driven-right-leg circuit in electroencephalographic recording with a minimum number of electrodes. Paper presented at the Proceedings of the 26th Annual International Conference of the IEEE EMBS, 1-5 Sept 2004, San Francisco, CA, 2247-2250 (Pubitemid 40035870)
    • (2004) Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings , vol.III26 , pp. 2247-2250
    • Nonclercq, A.1    Mathys, P.2
  • 13
    • 0029411942 scopus 로고
    • Multichannel PC-based data-acquisition system for high-resolution EEG
    • Dunseath, W. J. R. and Kelly, E. F., 1995, Multichannel PC-based data-acquisition system for high-resolution EEG. IEEE Transactions on Biomedical Engineering, 42, 1212-1217.
    • (1995) IEEE Transactions on Biomedical Engineering , vol.42 , pp. 1212-1217
    • Dunseath, W.J.R.1    Kelly, E.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.