메뉴 건너뛰기




Volumn 37, Issue , 2010, Pages 1-4

MRI-based quantification of myocardial perfusion at rest and stress using automated frame-by-frame segmentation and non-rigid registration

Author keywords

[No Author keywords available]

Indexed keywords

AUTOMATED DETECTION; CARDIAC MAGNETIC RESONANCE; CONTRAST ENHANCEMENT; CONTRAST-ENHANCED IMAGES; CROSS CORRELATIONS; DYNAMIC NATURE; EDGE-BASED; EPI-CARDIAL BOUNDARIES; EPICARDIAL BORDERS; EXPECTED EFFECTS; IMAGE SEQUENCE; INFLOW RATE; LEFT VENTRICLES; LEVEL-SET TECHNIQUES; MULTISCALES; MYOCARDIAL PERFUSION; NOISE LEVELS; NONRIGID REGISTRATION; PEAK AMPLITUDE; REGION-BASED; RESPIRATORY MOTIONS; TIME CURVES; TYPICAL PATTERNS;

EID: 79953833661     PISSN: 23258861     EISSN: 2325887X     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (8)

References (5)
  • 1
    • 0032755671 scopus 로고    scopus 로고
    • Magnetic resonance first-pass myocardial perfusion imaging: Clinical validation and future applications
    • DOI 10.1002/(SICI)1522-2586(199911)10:5<676::AID-JMRI10>3.0.CO;2-L
    • Wilke NM, Jerosch-Herold M; Zenovich A, Stillman AE, Magnetic resonance first-pass myocardial perfusion imaging: clinical validation and future applications. J Magn Reson Imaging 10:676-685; 1999. (Pubitemid 29519768)
    • (1999) Journal of Magnetic Resonance Imaging , vol.10 , Issue.5 , pp. 676-685
    • Wilke, N.M.1    Jerosch-Herold, M.2    Zenovich, A.3    Stillman, A.E.4
  • 2
    • 63449086330 scopus 로고    scopus 로고
    • Automated frame-by-frame endocardial border detection from cardiac magnetic resonance images for quantitative assessment of left ventricular function: Validation and clinical feasibility
    • Corsi C, Veronesi F, Lamberti C, Bardo DME, Jamison E, Lang RM, Mor-Avi V, Automated frame-by-frame endocardial border detection from cardiac magnetic resonance images for quantitative assessment of left ventricular function: Validation and clinical feasibility. J Magn Reson Imaging 29:560-568; 2009.
    • (2009) J Magn Reson Imaging , vol.29 , pp. 560-568
    • Corsi, C.1    Veronesi, F.2    Lamberti, C.3    Bardo, D.M.E.4    Jamison, E.5    Lang, R.M.6    Mor-Avi, V.7
  • 3
    • 84990602490 scopus 로고
    • Optimal approximation by piecewise smooth functions and associated variational problems
    • Mumford D, Shah J, Optimal approximation by piecewise smooth functions and associated variational problems. Commun Pure Appl Math 42:577-685, 1989.
    • (1989) Commun Pure Appl Math , vol.42 , pp. 577-685
    • Mumford, D.1    Shah, J.2
  • 4
    • 0029118131 scopus 로고
    • Image processing via level set curvature flow
    • Malladi R, Sethian JA, Image processing via level set curvature flow. Proc Natl Acad Sci 92:7046-7050; 1995.
    • (1995) Proc Natl Acad Sci , vol.92 , pp. 7046-7050
    • Malladi, R.1    Sethian, J.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.