메뉴 건너뛰기




Volumn 1, Issue 1, 2008, Pages 17-28

Quantitative evaluation of retinal tumor volume in mouse model of retinoblastoma by using ultra high-resolution optical coherence tomography

Author keywords

3D imaging; image segmentation; mouse models; optical coherence tomography; retina

Indexed keywords

3D IMAGING; AREAS OF INTERESTS; AUTOMATIC SEGMENTATIONS; DISEASE PROGRESSION; FUNDUS IMAGE; HIGH RESOLUTION; IN-VIVO; MOUSE MODELS; NON-CONTACT; OCULAR DISEASE; POSITIONING SYSTEM; QUANTITATIVE EVALUATION; RETINA; RETINOBLASTOMA; RODENT MODELS; SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY; THREE DIMENSIONAL IMAGING; TIME POINTS; TUMOR BOUNDARY; TUMOR GROWTH; TUMOR VOLUMES; ULTRAHIGH RESOLUTION;

EID: 79953829268     PISSN: 17935458     EISSN: 17937205     Source Type: Journal    
DOI: 10.1142/S1793545808000066     Document Type: Article
Times cited : (5)

References (17)
  • 1
    • 0025073122 scopus 로고
    • The incidence of retinoblastoma in the United States: 1974 through 1985
    • A. Tamboli, M. J. Podgor and J. W. Horm, "The incidence of retinoblastoma in the United States: 1974 through 1985," Archives Ophthalmology 108, 128-132 (1990). (Pubitemid 20031427)
    • (1990) Archives of Ophthalmology , vol.108 , Issue.1 , pp. 128-132
    • Tamboli, A.1    Podgor, M.J.2    Horm, J.W.3
  • 2
    • 0018934064 scopus 로고
    • Incidence of retinoblastoma in the United States
    • T. W. Pendergrass, S. Davis, "Incidence of retinoblastoma in the United States," Archives Ophthalmology 98, 1204-1210 (1980). (Pubitemid 10033710)
    • (1980) Archives of Ophthalmology , vol.98 , Issue.7 , pp. 1204-1210
    • Pendergrass, T.W.1    Davis, S.2
  • 4
    • 0001936881 scopus 로고
    • Measurement of intraocular distances by backscattering spectral interferometry
    • A. F. Fercher, C. K. Hitzenberger, G. Kamp and S. Y. El-Zaiat. "Measurement of intraocular distances by backscattering spectral interferometry," Optics Communications 117, 43-48 (1995).
    • (1995) Optics Communications , vol.117 , pp. 43-48
    • Fercher, A.F.1    Hitzenberger, C.K.2    Kamp, G.3    El-Zaiat, S.Y.4
  • 6
    • 0034776940 scopus 로고    scopus 로고
    • Progressive change of optical coherence tomography scans in retinal degeneration slow mice
    • N. Horio, S. Kachi, K. Hori, Y. Okamoto, E. Yamamoto, H. Terasaki and Y. Miyake, "Progressive change of optical coherence tomography scans in retinal degeneration slow mice," Archives Ophthalmology 119, 1329-1332 (2001). (Pubitemid 32994878)
    • (2001) Archives of Ophthalmology , vol.119 , Issue.9 , pp. 1329-1332
    • Horio, N.1    Kachi, S.2    Hori, K.3    Okamoto, Y.4    Yamamoto, E.5    Terasaki, H.6    Miyake, Y.7
  • 7
    • 34248590477 scopus 로고    scopus 로고
    • In vivo ultrahigh resolution optical coherence tomography for the quantification of retinal structure in normal and transgenic mice
    • (ARVO Abstract #4252)
    • I. Hartl, T. Ko, R. K. Ghanta,W. Drexler, A. Clermont, S. E. Bursell and J. G. Fujimoto, "In vivo ultrahigh resolution optical coherence tomography for the quantification of retinal structure in normal and transgenic mice," Investigative Ophthalmology & Visual Science 42, S793, 2001 (ARVO Abstract #4252).
    • (2001) Investigative Ophthalmology & Visual Science , vol.42
    • Hartl, I.1    Ko, T.2    Ghanta, W.3    Drexler, R.K.4    Clermont, A.5    Bursell, S.E.6    Fujimoto, J.G.7
  • 12
    • 0025057103 scopus 로고
    • Retinoblastoma in transgenic mice
    • J. J. Windle, D. M. Albert and J. M. O'Brien, "Retinoblastoma in transgenic mice," Nature 343, 665-669 (1990).
    • (1990) Nature , vol.343 , pp. 665-669
    • Windle, J.J.1    Albert, D.M.2    O'Brien, J.M.3
  • 13
    • 0021925652 scopus 로고
    • A schematic eye for the mouse, and comparisons with the rat
    • DOI 10.1016/0042-6989(85)90076-8
    • S. Remtulla and P. E. Hallett, "A schematic eye for the mouse, and comparisons with the rat," Vision Research. 25, 21-31 (1985). (Pubitemid 15165475)
    • (1985) Vision Research , vol.25 , Issue.1 , pp. 21-31
    • Remtulla, S.1    Hallett, P.E.2
  • 14
    • 13544265585 scopus 로고    scopus 로고
    • Simultaneous acquisition of sectional and fundus ophthalmic images with spectral-domain optical coherence tomography
    • DOI 10.1364/OPEX.13.000444
    • S. Jiao, R. Knighton, X. Huang, G. Gregori and C. Puliafito, "Simultaneous acquisition of sectional and fundus ophthalmic images with spectral-domain optical coherence tomography," Optics Express 13, 444-452 (2005) http://www.opticsinfobase. org/abstract.cfm?URI=oe-13-2-444 (Pubitemid 40224918)
    • (2005) Optics Express , vol.13 , Issue.2 , pp. 444-452
    • Jiao, S.1    Knighton, R.2    Huang, X.3    Gregori, G.4    Puliafito, C.A.5
  • 15
    • 48149097875 scopus 로고    scopus 로고
    • CRF-based segmentation of human tear meniscus obtained with optical coherence tomography
    • San Antonio, TX,September
    • G. Tsechpenakis and J. Wang, "CRF-based segmentation of human tear meniscus obtained with optical coherence tomography," IEEE International conference on Image Processing (ICIP), San Antonio, TX, September 2007.
    • (2007) IEEE International Conference on Image Processing (ICIP)
    • Tsechpenakis, G.1    Wang, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.