-
1
-
-
27744494655
-
Laparoscopic nephrectomy using ligasure system: Preliminary experience
-
DOI 10.1089/end.2005.19.976
-
Leonardo C, Guaglianone S, De Carli P, et. al. "Laparoscopic Nephrectomy Using Ligasure System: Preliminary Experience, " J Endourol. 19(8), 976-8 (2005). (Pubitemid 41619157)
-
(2005)
Journal of Endourology
, vol.19
, Issue.8
, pp. 976-978
-
-
Leonardo, C.1
Guaglianone, S.2
De Carli, P.3
Pompeo, V.4
Forastiere, E.5
Gallucci, M.6
-
2
-
-
18844456840
-
Comparative study of electrothermal bipolar vessel sealer and ultrasonic coagulating shears in laparoscopic colectomy
-
DOI 10.1007/s00464-004-9072-x
-
Takada M, Ichihara T, Kuroda Y. "Comparative study of electrothermal bipolar vessel sealer and ultrasonic coagulating shears in laparoscopic colectomy." Surg Endosc. 19, 226-8 (2005). (Pubitemid 40685191)
-
(2005)
Surgical Endoscopy
, vol.19
, Issue.2
, pp. 226-228
-
-
Takada, M.1
Ichihara, T.2
Kuroda, Y.3
-
3
-
-
39149134560
-
Comparison of four energy-based vascular sealing and cutting instruments: A porcine model
-
Person B, Vivas DA, Ruiz D, et. al. "Comparison of four energy-based vascular sealing and cutting instruments: A porcine model." Surg Endosc. 22, 534-8 (2008).
-
(2008)
Surg Endosc.
, vol.22
, pp. 534-538
-
-
Person, B.1
Vivas, D.A.2
Ruiz, D.3
-
4
-
-
0041357211
-
Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries
-
DOI 10.1007/s00464-002-8833-7
-
Harold KL, Pollinger H, Matthews BD, et. al., "Comparison of ultrasonic energy, bipolar thermal energy and vascular clips for hemostasis of small, medium, and large size arteries." Surg Endosc. 17, 1228- 30 (2003). (Pubitemid 37064797)
-
(2003)
Surgical Endoscopy
, vol.17
, Issue.8
, pp. 1228-1230
-
-
Harold, K.L.1
Pollinger, H.2
Matthews, B.D.3
Kercher, K.W.4
Sing, R.F.5
Heniford, B.T.6
-
5
-
-
0032094281
-
High-burst-strength, feedback-controlled bipolar vessel sealing
-
Kennedy JS, Stranahan PL, Taylor KD, et. al., "High burst-strength, feedback-controlled bipolar vessel sealing." Surg Endosc. 12, 876-8 (1998). (Pubitemid 128529367)
-
(1998)
Surgical Endoscopy
, vol.12
, Issue.6
, pp. 876-878
-
-
Kennedy, J.S.1
Stranahan, P.L.2
Taylor, K.D.3
Chandler, J.G.4
-
6
-
-
0037306077
-
Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model
-
DOI 10.1016/S0022-5347(05)63995-X
-
Landman J, Kerbl K, Rehman J, et. al. "Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model." J Urol. 169, 697-700 (2003). (Pubitemid 36133025)
-
(2003)
Journal of Urology
, vol.169
, Issue.2
, pp. 697-700
-
-
Landman, J.1
Kerbl, K.2
Rehman, J.3
Andreoni, C.4
Humphrey, P.A.5
Collyer, W.6
Olweny, E.7
Sundaram, C.8
Clayman, R.V.9
-
7
-
-
34548293192
-
Developing clinically successful biomedical devices by understanding the pathophysiology of the target tissue: Insights from over 25 years at the microscope
-
Thomsen SL, Coad JE. "Developing clinically successful biomedical devices by understanding the pathophysiology of the target tissue: insights from over 25 years at the microscope." Proc. SPIE 6440, 1-15 (2007).
-
(2007)
Proc. SPIE
, vol.6440
, pp. 1-15
-
-
Thomsen, S.L.1
Coad, J.E.2
-
8
-
-
35748971736
-
Evaluation of Surgical Energy Devices for Vessel Sealing and Peripheral Energy Spread in a Porcine Model
-
DOI 10.1016/j.juro.2007.07.121, PII S0022534707019672
-
Hruby GW, Marruffo FC, Durak E, et. al. "Evaluation of surgical energy devices for vessel sealing and peripheral energy spread in a porcine model." J Urol. 178, 2689-93 (2007). (Pubitemid 350052146)
-
(2007)
Journal of Urology
, vol.178
, Issue.6
, pp. 2689-2693
-
-
Hruby, G.W.1
Marruffo, F.C.2
Durak, E.3
Collins, S.M.4
Pierorazio, P.5
Humphrey, P.A.6
Mansukhani, M.M.7
Landman, J.8
-
9
-
-
0043123286
-
Radiofrequency ablation causes 'thermal fixation' of hepatocellular carcinoma: A post-liver transplant histopathologic study
-
DOI 10.1034/j.1399-0012.2003.00062.x
-
Coad JE, Kosari K, Humar A, et. al. "Radiofrequency ablation (RFA) causes thermal fixation of hepatocellular carcinoma: a post-liver transplant histopathologic study." Clin Transplant. 17, 377-84 (2003). (Pubitemid 36958201)
-
(2003)
Clinical Transplantation
, vol.17
, Issue.4
, pp. 377-384
-
-
Coad, J.E.1
Kosari, K.2
Humar, A.3
Sielaff, T.D.4
-
10
-
-
23244465128
-
Thermal fixation: A central outcome of hyperthermic therapies
-
DOI 10.1117/12.591175, 02, Thermal Treatment of Tissue: Energy Delivery and Assessment III
-
Coad JE, "Thermal fixation: A central outcome of hyperthermic therapies." Proc. SPIE 5698, 15-22 (2005). (Pubitemid 41091485)
-
(2005)
Progress in Biomedical Optics and Imaging - Proceedings of SPIE
, vol.5698
, pp. 15-22
-
-
Coad, J.E.1
-
11
-
-
0141605809
-
Histologic differences between cryothermic and hyperthermic therapies
-
Coad JE, Bischof JC. "Histologic differences between cryothermic and hyperthermic therapies." Proc. SPIE: 4954, 27-36 (2003).
-
(2003)
Proc. SPIE
, vol.4954
, pp. 27-36
-
-
Coad, J.E.1
Bischof, J.C.2
-
13
-
-
33749002228
-
Comparison of monopolar electrocoagulation, bipolar electrocoagulation, ultracision, and ligasure
-
DOI 10.1007/s00595-006-3254-1
-
Diamantis T, Kontos M, Arvelakis A, et. al. "Comparison of monopolar electrocoagulation, bipolar electrocoagulation, ultracision, and ligasure." Surg Today. 36, 908-13 (2006). (Pubitemid 44453918)
-
(2006)
Surgery Today
, vol.36
, Issue.10
, pp. 908-913
-
-
Diamantis, T.1
Kontos, M.2
Arvelakis, A.3
Syroukis, S.4
Koronarchis, D.5
Papalois, A.6
Agapitos, E.7
Bastounis, E.8
Lazaris, A.C.9
-
14
-
-
33750107219
-
Differential response of arteries and veins to bipolar vessel sealing: Evaluation of a novel reusable device
-
DOI 10.1089/lap.2006.16.149
-
Richter S, Kollmar O, Neunhoeffer E, et. al. "Differential response of arteries and veins to bipolar vessel sealing: evaluation of a novel reusable device." J Laproendosc Adv Surg Tech. 16(2), 149-55 (2006). (Pubitemid 44606408)
-
(2006)
Journal of Laparoendoscopic and Advanced Surgical Techniques
, vol.16
, Issue.2
, pp. 149-155
-
-
Richter, S.1
Kollmar, O.2
Neunhoeffer, E.3
Schilling, M.K.4
Menger, M.D.5
Pistorius, G.6
-
15
-
-
65949124021
-
Healing responses following cryothermic and hyperthermic tissue ablation
-
Godwin BL, Coad JE. "Healing responses following cryothermic and hyperthermic tissue ablation." Proc. SPIE 7181, 1-9 (2009).
-
(2009)
Proc. SPIE
, vol.7181
, pp. 1-9
-
-
Godwin, B.L.1
Coad, J.E.2
|