Volumn 15, Issue 1, 2011, Pages 24-29

Electrolytes assessed by point-of-care testing - Are the values comparable with results obtained from the central laboratory?

Author keywords

Agreement; bland and altman; concordance; electrolytes; point of care testing

Indexed keywords

ELECTROLYTE; POTASSIUM; SODIUM;

EID: 79953805872     PISSN: 09725229     EISSN: 1998359X     Source Type: Journal    
DOI: 10.4103/0972-5229.78219     Document Type: Article
Times cited : (32)

References (11)
  • 1
    • 0035009464 scopus 로고    scopus 로고
    • Acute care testing: Blood gases and electrolytes at the point of care
    • Cox CJ. Acute care testing Blood gases and electrolytes at the point of care. Clin Lab Med 2001;21:321-35. (Pubitemid 32488736)
    • (2001) Clinics in Laboratory Medicine , vol.21 , Issue.2 , pp. 321-335
    • Cox, C.J.1
  • 2
    • 0037407607 scopus 로고    scopus 로고
    • Comparison of point-of-care versus central laboratory measurement of electrolyte concentrations on calculations of the anion gap and the strong ion difference
    • DOI 10.1097/00000542-200305000-00009
    • Morimatsu H, Rocktäschel J, Bellomo R, Uchino S, Goldsmith D, Gutteridge G. Comparison of point-of-care versus central laboratory measurement of electrolyte concentrations on calculations of the anion gap and the strong ion difference. Anesthesiology 2003;98:1077-84. (Pubitemid 36520194)
    • (2003) Anesthesiology , vol.98 , Issue.5 , pp. 1077-1084
    • Morimatsu, H.1    Rocktaschel, J.2    Bellomo, R.3    Uchino, S.4    Goldsmith, D.5    Gutteridge, G.6
  • 3
    • 33749073889 scopus 로고    scopus 로고
    • Clinical evaluation of the ABL-77 for point-of-care analysis in the cardiovascular operating room
    • Prichard JS, French JS, Alvar N. Clinical evaluation of the ABL-77 for point-of-care analysis in the cardiovascular operating room. J Extra Corpor Technol 2006;38:128-33. (Pubitemid 351506596)
    • (2006) Journal of Extra-Corporeal Technology , vol.38 , Issue.2 , pp. 128-133
    • Prichard, J.S.1    French, J.S.2    Alvar, N.3
  • 4
    • 0013317179 scopus 로고    scopus 로고
    • Multi-site performance evaluation of pH, blood gas, electrolyte, glucose, and lactate determinations with the GEM premier 3000 critical care analyzer
    • Jacobs E, Ancy JJ, Smith M. Multi-site performance evaluation of pH, blood gas, electrolyte, glucose, and lactate determinations with the GEM Premier 3000 critical care analyzer. J Near Pat Test Techno 2002;1:135-44.
    • (2002) J. Near Pat Test Techno , vol.1 , pp. 135-144
    • Jacobs, E.1    Ancy, J.J.2    Smith, M.3
  • 5
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • DOI 10.1191/096228099673819272
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999;8:135-60. (Pubitemid 29425900)
    • (1999) Statistical Methods in Medical Research , vol.8 , Issue.2 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 6
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics 1989;45:255-68.
    • (1989) Biometrics , vol.45 , pp. 255-268
    • Lin, L.I.1
  • 7
    • 34047244948 scopus 로고    scopus 로고
    • Electrolytes and blood gases, Ch. 27
    • Burtis CA, Ashwood Er, Bruns DE, editors, 4th ed. Missouri USA: Elsevier
    • Scott MG, LeGrys VA, Klufts JC. Electrolytes and Blood gases, Ch. 27. In: Burtis CA, Ashwood Er, Bruns DE, editors. Tietz Textbook of Clinical Chemistry. 4th ed. Missouri USA: Elsevier; 2006. p. 985.
    • (2006) Tietz Textbook of Clinical Chemistry , pp. 985
    • Scott, M.G.1    LeGrys, V.A.2    Klufts, J.C.3
  • 8
    • 0042611725 scopus 로고
    • Pseudohyperkalemia with thrombocytosis
    • Ingram RH Jr, Seki M. Pseudohyperkalemia with thrombocytosis. N Engl J Med 1962;267:895-900.
    • (1962) N. Engl. J. Med. , vol.267 , pp. 895-900
    • Ingram Jr., R.H.1    Seki, M.2
  • 9
    • 0018092796 scopus 로고
    • Evaluation of a computer directed pneumatic tube system for pneumatic transport of blood specimens
    • Weaver DK, Miller D, Leventhal EA, Tropeano V. Evaluation of a computer-directed pneumatic-tube system for pneumatic transport of blood specimens. Am J Clin Pathol 1978;70:400-5. (Pubitemid 9026091)
    • (1978) American Journal of Clinical Pathology , vol.70 , Issue.3 , pp. 400-405
    • Weaver, D.K.1    Miller, D.2    Leventhal, E.A.3    Tropeano, V.4
  • 11
    • 77953477667 scopus 로고    scopus 로고
    • Comparison of the point-of-care blood gas analyzer versus the laboratory auto-analyzer for the measurement of electrolytes
    • Jain A, Subhan I, Joshi M. Comparison of the point-of-care blood gas analyzer versus the laboratory auto-analyzer for the measurement of electrolytes. Int J Emerg Med 2009;2:117-20.
    • (2009) Int. J. Emerg. Med. , vol.2 , pp. 117-120
    • Jain, A.1    Subhan, I.2    Joshi, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.