메뉴 건너뛰기




Volumn 20, Issue 2, 2011, Pages 383-388

Omnidirectional actuation of magnetically driven microtool for cutting of oocyte in a chip

Author keywords

Enucleation; magnetically driven microtool (MMT); microfluidic chip; oocyte

Indexed keywords

CELL MANIPULATION; ENUCLEATION; FOUR-LEG; MAGNETIC FORCE; MICRO-TOOL; MICROFLUIDIC CHIP; NON-CONTACT; OOCYTE; ORIGINAL DESIGN;

EID: 79953763061     PISSN: 10577157     EISSN: None     Source Type: Journal    
DOI: 10.1109/JMEMS.2010.2100028     Document Type: Article
Times cited : (26)

References (31)
  • 1
    • 0025512077 scopus 로고
    • Electrostatic manipulation of DNA in mi-crofabricated structures
    • Nov./Dec.
    • M. Washizu and O. Kurosawa, "Electrostatic manipulation of DNA in mi-crofabricated structures," IEEE Trans. Ind. Appl., vol. 26, no. 6, pp. 1165-1172, Nov./Dec. 1990.
    • (1990) IEEE Trans. Ind. Appl. , vol.26 , Issue.6 , pp. 1165-1172
    • Washizu, M.1    Kurosawa, O.2
  • 2
    • 0037097146 scopus 로고    scopus 로고
    • Manipulation of bacterial adhesion and proliferation by surface charges of electrically polarized hydroxyapatite
    • DOI 10.1002/jbm.10113
    • M. Ueshima, S. Tanaka, S. Nakamura, and K. Yamashita, "Manipulation of bacterial adhesion and proliferation by surface charges of electrically polarized hydroxyapatite," J. Biomed. Mater. Res. A, vol. 60, no. 4, pp. 578-584, Jun. 2002. (Pubitemid 34492596)
    • (2002) Journal of Biomedical Materials Research , vol.60 , Issue.4 , pp. 578-584
    • Ueshima, M.1    Tanaka, S.2    Nakamura, S.3    Yamashita, K.4
  • 3
    • 18144397437 scopus 로고    scopus 로고
    • Utilization of cell-sized lipid containers for nanostructure and macromolecule handling in microfabricated devices
    • DOI 10.1021/ac048207o
    • G. Tresset and S. Takeuchi, "Utilization of cell-sized lipid containers for nanostructure and macromolecule handling in microfabricated devices," Anal. Chem., vol. 77, no. 9, pp. 2795-2801, May 2005. (Pubitemid 40617326)
    • (2005) Analytical Chemistry , vol.77 , Issue.9 , pp. 2795-2801
    • Tresset, G.1    Takeuchi, S.2
  • 4
    • 70449843673 scopus 로고    scopus 로고
    • Bacteria concentration using a membrane type insulator-based dielectrophoresis in a plastic chip
    • Sep.
    • Y.-K. Cho, S. Kim, K. Lee, C. Park, J.-G. Lee, and C. Ko, "Bacteria concentration using a membrane type insulator-based dielectrophoresis in a plastic chip," Electrophoresis, vol. 30, no. 18, pp. 3153-3159, Sep. 2009.
    • (2009) Electrophoresis , vol.30 , Issue.18 , pp. 3153-3159
    • Cho, Y.-K.1    Kim, S.2    Lee, K.3    Park, C.4    Lee, J.-G.5    Ko, C.6
  • 6
    • 48949114936 scopus 로고    scopus 로고
    • T cell activation on a single-cell level in dielectrophoresis-based microfluidic devices
    • Aug.
    • M. Kirschbaum, M. S. Jaeger, T. Schenkel, T. Breinig, A. Meyerhans, and C. Duschl, "T cell activation on a single-cell level in dielectrophoresis-based microfluidic devices," J. Chromatogr. A, vol. 1202, no. 1, pp. 83-89, Aug. 2008.
    • (2008) J. Chromatogr. A , vol.1202 , Issue.1 , pp. 83-89
    • Kirschbaum, M.1    Jaeger, M.S.2    Schenkel, T.3    Breinig, T.4    Meyerhans, A.5    Duschl, C.6
  • 7
    • 64049096058 scopus 로고    scopus 로고
    • Negative dielec-trophoretic patterning with different cell types
    • Dec.
    • M. Suzuki, T. Yasukawa, H. Shiku, and T. Matsue, "Negative dielec-trophoretic patterning with different cell types," Biosens. Bioelectron., vol. 24, no. 4, pp. 1043-1047, Dec. 2008.
    • (2008) Biosens. Bioelectron. , vol.24 , Issue.4 , pp. 1043-1047
    • Suzuki, M.1    Yasukawa, T.2    Shiku, H.3    Matsue, T.4
  • 8
    • 70249141658 scopus 로고    scopus 로고
    • An integrated dielectrophoretic chip for continuous bioparticle filtering, focusing, sorting, trapping, and detecting
    • Jun.
    • I.-F. Cheng, H.-C. Chang, D. Hou, and H.-C. Chang, "An integrated dielectrophoretic chip for continuous bioparticle filtering, focusing, sorting, trapping, and detecting," Biomicrofluidics, vol. 1, no. 2, p. 021 503, Jun. 2007.
    • (2007) Biomicrofluidics , vol.1 , Issue.2 , pp. 021-503
    • Cheng, I.-F.1    Chang, H.-C.2    Hou, D.3    Chang, H.-C.4
  • 9
    • 0037350785 scopus 로고    scopus 로고
    • Pinpoint injection of microtools for minimally invasive micromanipulation of microbe by laser trap
    • Mar.
    • F. Arai, H. Maruyama, T. Sakami, A. Ichikawa, and T. Fukuda, "Pinpoint injection of microtools for minimally invasive micromanipulation of microbe by laser trap," IEEE/ASME Trans. Mechatronics, vol. 8, no. 1, pp. 3-9, Mar. 2003.
    • (2003) IEEE/ ASME Trans. Mechatronics , vol.8 , Issue.1 , pp. 3-9
    • Arai, F.1    Maruyama, H.2    Sakami, T.3    Ichikawa, A.4    Fukuda, T.5
  • 10
    • 65049087882 scopus 로고    scopus 로고
    • Cell separation by the combination of microfluidics and optical trapping force on a microchip
    • May
    • M. Murata, Y. Okamoto, Y.-S. Park, N. Kaji, M. Tokeshi, and Y. Baba, "Cell separation by the combination of microfluidics and optical trapping force on a microchip," Anal. Bioanal. Chem., vol. 394, no. 1, pp. 277-283, May 2009.
    • (2009) Anal. Bioanal. Chem. , vol.394 , Issue.1 , pp. 277-283
    • Murata, M.1    Okamoto, Y.2    Park, Y.-S.3    Kaji, N.4    Tokeshi, M.5    Baba, Y.6
  • 11
    • 56249148823 scopus 로고    scopus 로고
    • Motion of a red blood cell in interference field
    • Jan.
    • L. A. Viera, I. Lira, L. Soto, and C. Pavez, "Motion of a red blood cell in interference field," Opt. Commun., vol. 282, no. 1, pp. 64-68, Jan. 2009.
    • (2009) Opt. Commun. , vol.282 , Issue.1 , pp. 64-68
    • Viera, L.A.1    Lira, I.2    Soto, L.3    Pavez, C.4
  • 12
    • 51149107386 scopus 로고    scopus 로고
    • Optical trapping and manipulation of live T cells with a low numerical aperture lens
    • Sep.
    • J. Harris and G. McConnell, "Optical trapping and manipulation of live T cells with a low numerical aperture lens," Opt. Express, vol. 16, no. 18, pp. 14 036-14 043, Sep. 2008.
    • (2008) Opt. Express , vol.16 , Issue.18 , pp. 14036-14043
    • Harris, J.1    McConnell, G.2
  • 13
    • 33646912972 scopus 로고    scopus 로고
    • Laser trap studies of end-on E. coli adhesion to glass
    • DOI 10.1016/j.colsurfb.2006.04.004, PII S0927776506001354
    • J. F. Jones and D. Velegol, "Laser trap studies of end-on E. coli adhesion to glass," Colloids Surf. B, Biointerfaces, vol. 50, no. 1, pp. 66-71, Jun. 2006. (Pubitemid 43794896)
    • (2006) Colloids and Surfaces B: Biointerfaces , vol.50 , Issue.1 , pp. 66-71
    • Jones, J.F.1    Velegol, D.2
  • 15
    • 0141930312 scopus 로고    scopus 로고
    • Magnetic micro-actuators and systems (MAGMAS)
    • Nov.
    • O. Cugat, J. Delamare, and G. Reyne, "Magnetic micro-actuators and systems (MAGMAS)," IEEE Trans. Magn., vol. 39, no. 6, pp. 3607-3612, Nov. 2003.
    • (2003) IEEE Trans. Magn. , vol.39 , Issue.6 , pp. 3607-3612
    • Cugat, O.1    Delamare, J.2    Reyne, G.3
  • 19
    • 33644835521 scopus 로고    scopus 로고
    • Magnetism and microfluidics
    • Jan.
    • N. Pamme, "Magnetism and microfluidics," Lab Chip, vol. 6, no. 1, pp. 24-38, Jan. 2006.
    • (2006) Lab Chip , vol.6 , Issue.1 , pp. 24-38
    • Pamme, N.1
  • 21
    • 0040158420 scopus 로고    scopus 로고
    • Electromagnetic micromotor for microfluidics applications
    • DOI 10.1063/1.1398319
    • M. Barbic, J. J. Mock, A. P. Gray, and S. Schultz, "Electromagnetic micromotor for microfluidics applications," Appl. Phys. Lett., vol. 79, no. 9, pp. 1399-1401, Aug. 2001. (Pubitemid 33599613)
    • (2001) Applied Physics Letters , vol.79 , Issue.9 , pp. 1399-1401
    • Barbic, M.1    Mock, J.J.2    Gray, A.P.3    Schultz, S.4
  • 22
    • 33746413752 scopus 로고    scopus 로고
    • An electromagnetic micromanipulation system for single-cell manipulation
    • M. Gauthier and E. Piat, "An electromagnetic micromanipulation system for single-cell manipulation," J. Micromechatron., vol. 2, no. 2, pp. 87-119, 2002.
    • (2002) J. Micromechatron. , vol.2 , Issue.2 , pp. 87-119
    • Gauthier, M.1    Piat, E.2
  • 23
    • 69549130055 scopus 로고    scopus 로고
    • On-chip microparticle handling using magnetically driven microdevice
    • H. Maruyama, F. Arai, and T. Fukuda, "On-chip microparticle handling using magnetically driven microdevice," in Proc. μ-TAS, 2005, pp. 1422-1424.
    • (2005) Proc. μ-TAS , pp. 1422-1424
    • Maruyama, H.1    Arai, F.2    Fukuda, T.3
  • 25
    • 77957571229 scopus 로고    scopus 로고
    • Magnetically modified PDMS devices for active microfluidic control
    • Y. Yamanishi, Y. C. Lin, and F. Arai, "Magnetically modified PDMS devices for active microfluidic control," in Proc. μ-TAS, 2007, pp. 883-885.
    • (2007) Proc. μ-TAS , pp. 883-885
    • Yamanishi, Y.1    Lin, Y.C.2    Arai, F.3
  • 26
    • 62449221332 scopus 로고    scopus 로고
    • Biocompatible polymeric magnetically driven microtool for particle sorting
    • Nov.
    • Y. Yamanishi, S. Sakuma, K. Onda, and F. Arai, "Biocompatible polymeric magnetically driven microtool for particle sorting," J. Micro -Nano Mechatron., vol. 4, no. 1/2, pp. 49-57, Nov. 2008.
    • (2008) J. Micro -Nano Mechatron. , vol.4 , Issue.1-2 , pp. 49-57
    • Yamanishi, Y.1    Sakuma, S.2    Onda, K.3    Arai, F.4
  • 27
    • 65949098202 scopus 로고    scopus 로고
    • Powerful actuation of magnetized microtool by focused magnetic field on a disposable microflu-idic chip
    • F. Arai, S. Sakuma, Y. Yamanishi, and K. Onda, "Powerful actuation of magnetized microtool by focused magnetic field on a disposable microflu-idic chip," in Proc. 22nd IEEE Int. Conf. Micro Electro Mech. Syst., 2009, pp. 51-54.
    • (2009) Proc. 22nd IEEE Int. Conf. Micro Electro Mech. Syst. , pp. 51-54
    • Arai, F.1    Sakuma, S.2    Yamanishi, Y.3    Onda, K.4
  • 28
    • 34047260916 scopus 로고    scopus 로고
    • Mouse zona pellucida dynamically changes its elasticity during oocyte maturation, fertilization and early embryo development
    • Nov.
    • Y. Murayama, J. Mizuno, H. Kamakura, Y. Fueta, H. Nakamura, K. Akaishi, K. Anzai, A. Watanabe, H. Inui, and S. Omata, "Mouse zona pellucida dynamically changes its elasticity during oocyte maturation, fertilization and early embryo development," Jpn. Human Cell Soc., vol. 19, no. 4, pp. 119-125, Nov. 2007.
    • (2007) Jpn. Human Cell Soc. , vol.19 , Issue.4 , pp. 119-125
    • Murayama, Y.1    Mizuno, J.2    Kamakura, H.3    Fueta, Y.4    Nakamura, H.5    Akaishi, K.6    Anzai, K.7    Watanabe, A.8    Inui, H.9    Omata, S.10
  • 29
    • 3042844126 scopus 로고    scopus 로고
    • Mechanical property characterization of mouse zona pellucida
    • Dec.
    • Y. Sun, K.-T. Wan, K. P. Roberts, J. C. Bischof, and B. J. Nelson, "Mechanical property characterization of mouse zona pellucida," IEEE Trans. Nanobiosci., vol. 2, no. 4, pp. 279-286, Dec. 2003.
    • (2003) IEEE Trans. Nanobiosci. , vol.2 , Issue.4 , pp. 279-286
    • Sun, Y.1    Wan, K.-T.2    Roberts, K.P.3    Bischof, J.C.4    Nelson, B.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.