메뉴 건너뛰기




Volumn 12, Issue 1, 2011, Pages 67-70

Case study: First implantation of a frozen, devitalized tissueengineered vascular graft for urgent hemodialysis access

Author keywords

Autologous cell; ESRD (end stage renal disease); Graft devitalization; Hemodialysis; Vascular graft; Vascular tissue engineering

Indexed keywords

AGED; ARTERIOVENOUS FISTULA; ARTICLE; BLOOD VESSEL GRAFT; CASE REPORT; DIALYSIS CATHETER; ENDOTHELIUM CELL; FEMORAL VEIN; FIBROBLAST; HEMODIALYSIS; HUMAN; MALE; TISSUE ENGINEERING; VASCULAR ACCESS;

EID: 79953676333     PISSN: 11297298     EISSN: None     Source Type: Journal    
DOI: 10.5301/JVA.2011.6360     Document Type: Article
Times cited : (72)

References (13)
  • 1
    • 0242408269 scopus 로고    scopus 로고
    • Patency of autogenous and polytetrafluoroethylene upper extremity arteriovenous hemodialysis accesses: A systematic review
    • Huber TS, Carter JW, Carter RL, Seeger JM. Patency of autogenous and polytetrafluoroethylene upper extremity arteriovenous hemodialysis accesses: a systematic review. J Vasc Surg 2003; 38: 1005-11.
    • (2003) J Vasc Surg , vol.38 , pp. 1005-1011
    • Huber, T.S.1    Carter, J.W.2    Carter, R.L.3    Seeger, J.M.4
  • 2
    • 0035488017 scopus 로고    scopus 로고
    • Vascular access survival and incidence of revisions: A comparison of prosthetic grafts, simple autogenous fistulas, and venous transposition fistulas from the United States Renal Data System Dialysis Morbidity and Mortality Study
    • Gibson KD, Gillen DL, Caps MT, Kohler TR, Sherrard DJ, Stehman-Breen CO. Vascular access survival and incidence of revisions: a comparison of prosthetic grafts, simple autogenous fistulas, and venous transposition fistulas from the United States Renal Data System Dialysis Morbidity and Mortality Study. J Vasc Surg 2001; 34: 694-700.
    • (2001) J Vasc Surg , vol.34 , pp. 694-700
    • Gibson, K.D.1    Gillen, D.L.2    Caps, M.T.3    Kohler, T.R.4    Sherrard, D.J.5    Stehman-Breen, C.O.6
  • 3
    • 0025094473 scopus 로고
    • Use of a silicone dual-lumen catheter with a Dacron cuff as a long-term vascular access for hemodialysis patients
    • Moss AH, Vasilakis C, Holley JL, Foulks CJ, Pillai K, McDowell DE. Use of a silicone dual-lumen catheter with a Dacron cuff as a long-term vascular access for hemodialysis patients. Am J Kidney Dis 1990; 16: 211-5.
    • (1990) Am J Kidney Dis , vol.16 , pp. 211-215
    • Moss, A.H.1    Vasilakis, C.2    Holley, J.L.3    Foulks, C.J.4    Pillai, K.5    McDowell, D.E.6
  • 4
    • 0345367419 scopus 로고    scopus 로고
    • Replacement of failing tunneled hemodialysis catheters through pre-existing subcutaneous tunnels: A comparison of catheter function and infection rates for de novo placements and over-the-wire exchanges
    • Duszak R Jr, Haskal ZJ, Thomas-Hawkins C, et al. Replacement of failing tunneled hemodialysis catheters through pre-existing subcutaneous tunnels: a comparison of catheter function and infection rates for de novo placements and over-the-wire exchanges. J Vasc Interv Radiol 1998; 9: 321-7.
    • (1998) J Vasc Interv Radiol , vol.9 , pp. 321-327
    • Duszak Jr, R.1    Haskal, Z.J.2    Thomas-Hawkins, C.3
  • 5
    • 0033050901 scopus 로고    scopus 로고
    • Septicemia in dialysis patients: Incidence, risk factors, and prognosis
    • Powe NR, Jaar B, Furth SL, Hermann J, Briggs W. Septicemia in dialysis patients: incidence, risk factors, and prognosis. Kidney Int 1999; 55: 1081-90.
    • (1999) Kidney Int , vol.55 , pp. 1081-1090
    • Powe, N.R.1    Jaar, B.2    Furth, S.L.3    Hermann, J.4    Briggs, W.5
  • 6
    • 58249084560 scopus 로고    scopus 로고
    • Mechanical properties of completely autologous human tissue engineered blood vessels compared to human saphenousvein and mammary artery
    • Epub 2008 Dec 25
    • Konig G, McAllister TN, Dusserre N, et al. Mechanical properties of completely autologous human tissue engineered blood vessels compared to human saphenousvein and mammary artery. Biomaterials 2009; 30: 1542-50. Epub 2008 Dec 25.
    • (2009) Biomaterials , vol.30 , pp. 1542-1550
    • Konig, G.1    McAllister, T.N.2    Dusserre, N.3
  • 7
    • 32844467557 scopus 로고    scopus 로고
    • Outcomes of tunneled femoral hemodialysis catheters: Comparison with internal jugular vein catheters
    • Maya ID, Allon M. Outcomes of tunneled femoral hemodialysis catheters: comparison with internal jugular vein catheters. Kidney Int 2005; 68: 2886-9.
    • (2005) Kidney Int , vol.68 , pp. 2886-2889
    • Maya, I.D.1    Allon, M.2
  • 8
    • 64949112718 scopus 로고    scopus 로고
    • Effectiveness of haemodialysis access with an autologous tissue-engineered vascular graft: A multicentre cohort study
    • McAllister TN, Maruszewski M, Garrido SA, et al. Effectiveness of haemodialysis access with an autologous tissue-engineered vascular graft: a multicentre cohort study. Lancet 2009; 373: 1440-6.
    • (2009) Lancet , vol.373 , pp. 1440-1446
    • McAllister, T.N.1    Maruszewski, M.2    Garrido, S.A.3
  • 9
    • 34948849851 scopus 로고    scopus 로고
    • Tissueengineered blood vessel for adult arterial revascularization
    • L'Heureux N, McAllister TN, de la Fuente LM. Tissueengineered blood vessel for adult arterial revascularization. N Engl J Med 2007; 357: 1451-3.
    • (2007) N Engl J Med , vol.357 , pp. 1451-1453
    • L'heureux, N.1    McAllister, T.N.2    de la Fuente, L.M.3
  • 10
    • 0033802328 scopus 로고    scopus 로고
    • Viability of cryopreserved semilunar valves: An evaluation of cytosolic and mitochondrial activities
    • Tominaga T, Kitagawa T, Masuda Y, et al. Viability of cryopreserved semilunar valves: an evaluation of cytosolic and mitochondrial activities. Ann Thorac Surg 2000; 70: 792-5.
    • (2000) Ann Thorac Surg , vol.70 , pp. 792-795
    • Tominaga, T.1    Kitagawa, T.2    Masuda, Y.3
  • 11
    • 0034846009 scopus 로고    scopus 로고
    • Impact of current cryopreservation procedures on mechanical and functional properties of human aortic homografts
    • Langerak SE, Groenink M, van der Wall EE, et al. Impact of current cryopreservation procedures on mechanical and functional properties of human aortic homografts. Transpl Int 2001; 14: 248-55.
    • (2001) Transpl Int , vol.14 , pp. 248-255
    • Langerak, S.E.1    Groenink, M.2    van Der Wall, E.E.3
  • 12
    • 33747888562 scopus 로고    scopus 로고
    • Cryopreservation procedure does not modify human carotid homografts mechanical properties: An isobaric and dynamic analysis
    • Bia D, Pessana F, Armentano R, Pérez H, et al. Cryopreservation procedure does not modify human carotid homografts mechanical properties: an isobaric and dynamic analysis. Cell Tissue Bank 2006; 7: 183-94.
    • (2006) Cell Tissue Bank , vol.7 , pp. 183-194
    • Bia, D.1    Pessana, F.2    Armentano, R.3    Pérez, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.