메뉴 건너뛰기




Volumn 20, Issue 18, 2009, Pages 2249-2255

Detecting water accumulation in honeycomb sandwich structures by optical-fiber-based distributed temperature measurement

Author keywords

Honeycomb sandwich structure; Non uniform temperature; Optical fiber; Structural health monitoring; Water ingress

Indexed keywords

ADHESIVE LAYERS; AIRCRAFT OPERATORS; BRILLOUIN GAIN SPECTRUM; BRILLOUIN OPTICAL TIME DOMAIN ANALYSIS; HIGH SPATIAL RESOLUTION; HONEYCOMB SANDWICH STRUCTURE; INTERNAL TEMPERATURE DISTRIBUTION; NOMEX HONEYCOMBS; NON-UNIFORM TEMPERATURE; NONUNIFORMITY; OPTICAL-FIBER NETWORKS; PEAK FREQUENCIES; PRE-PUMP; SENSING SYSTEMS; SPATIAL RESOLUTION; SPECTRUM WIDTH; STRUCTURAL HEALTH; TEMPERATURE CHANGES; VERIFICATION TESTS; WATER ACCUMULATION; WATER INGRESS;

EID: 79953662281     PISSN: 1045389X     EISSN: 15308138     Source Type: Journal    
DOI: 10.1177/1045389X09352813     Document Type: Article
Times cited : (6)

References (14)
  • 1
    • 84882149360 scopus 로고
    • Stimulated brillouin scattering in monomode optical fiber
    • Cotter, D. 1983. "Stimulated Brillouin Scattering in Monomode Optical Fiber," Journal of Optical Communications, 4(1):10-19.
    • (1983) Journal of Optical Communications , vol.4 , Issue.1 , pp. 10-19
    • Cotter, D.1
  • 2
    • 0024963111 scopus 로고
    • Potential of stimulated brillouin scattering as sensing mechanism for distributed temperature sensors
    • Culverhouse, D., Farahi, F., Pannell, C.N. and Jackson, D.A. 1989. "Potential of Stimulated Brillouin Scattering as Sensing Mechanism for Distributed Temperature Sensors," Electronics Letters, 25(14):913-915.
    • (1989) Electronics Letters , vol.25 , Issue.14 , pp. 913-915
    • Culverhouse, D.1    Farahi, F.2    Pannell, C.N.3    Jackson, D.A.4
  • 4
    • 84890710090 scopus 로고    scopus 로고
    • Pulse pre-pump-botda technology for new generation of distributed strain measuring system
    • J.P, Ou, H, Li and Z.D, Duan (eds) Taylor & Francis, London
    • Kishida, K. and Li, C.H. 2006. "Pulse Pre-pump-BOTDA Technology for New Generation of Distributed Strain Measuring System," In: J.P, Ou, H, Li and Z.D, Duan (eds), Structural Health Monitoring and Intelligent Infrastructure, pp. 471-477, Taylor & Francis, London.
    • (2006) Structural Health Monitoring and Intelligent Infrastructure , pp. 471-477
    • Kishida, K.1    Li, C.H.2
  • 5
    • 18444388291 scopus 로고    scopus 로고
    • Detection of water ingress in composite sandwich structures: A magnetic resonance approach
    • DOI 10.1016/j.ndteint.2005.01.006, PII S0963869505000216
    • LaPlante, G., Marble, A.E., MacMillan, B., Lee-Sullivan, P., Colpitts, B.G. and Balcom, B.J. 2005. "Detection of Water Ingress in Composite Sandwich Structures: A Magnetic Resonance Approach," NDT & E International, 38(6):501-507. (Pubitemid 40643093)
    • (2005) NDT and E International , vol.38 , Issue.6 , pp. 501-507
    • Laplante, G.1    Marble, A.E.2    MacMillan, B.3    Lee-Sullivan, P.4    Colpitts, B.G.5    Balcom, B.J.6
  • 6
    • 33845537279 scopus 로고    scopus 로고
    • Real-time detection of debonding between honeycomb core and facesheet using a small-diameter FBG sensor embedded in adhesive layer
    • DOI 10.1177/1099636207064457
    • Minakuchi, S., Okabe, Y. and Takeda, N. 2007. "Real-time Detection of Debonding Between Honeycomb Core and Facesheet using a Small-diameter FBG Sensor Embedded in Adhesive Layer," Journal of Sandwich Structures and Materials, 9(1):9-33. (Pubitemid 44927137)
    • (2007) Journal of Sandwich Structures and Materials , vol.9 , Issue.1 , pp. 9-33
    • Minakuchi, S.1    Okabe, Y.2    Takeda, N.3
  • 7
    • 70349751743 scopus 로고    scopus 로고
    • Brillouin spectral response depending on the strain non-uniformity within centimeter spatial resolution and its application to internal damage detection in large-scale composite structures
    • Minakuchi, S., Mizutani, T., Tsukamoto, H., Nishio, M., Okabe, Y. and Takeda, N. 2008. "Brillouin Spectral Response Depending on the Strain Non-uniformity within Centimeter Spatial Resolution and its Application to Internal Damage Detection in Large-scale Composite Structures," Structural Durability & Health Monitoring, 4(4):199-219.
    • (2008) Structural Durability & Health Monitoring , vol.4 , Issue.4 , pp. 199-219
    • Minakuchi, S.1    Mizutani, T.2    Tsukamoto, H.3    Nishio, M.4    Okabe, Y.5    Takeda, N.6
  • 8
    • 70350643630 scopus 로고    scopus 로고
    • Barely visible impact damage detection for composite sandwich structures by optical-fiber-based distributed strain measurement
    • Minakuchi, S., Okabe, Y., Mizutani, T. and Takeda, N. 2009. "Barely Visible Impact Damage Detection for Composite Sandwich Structures by Optical-fiber-based Distributed Strain Measurement," Smart Materials and Structures, 18:085018.
    • (2009) Smart Materials and Structures , vol.18 , pp. 085018
    • Minakuchi, S.1    Okabe, Y.2    Mizutani, T.3    Takeda, N.4
  • 10
    • 79957945391 scopus 로고    scopus 로고
    • Neubrex Co. Ltd. Available online at: Accessed 2009
    • Neubrex Co., Ltd. Available online at: http://www.neubrex.jp (Accessed 2009).
  • 11
    • 0033283679 scopus 로고    scopus 로고
    • Evaluation of the in-service performance behavior of honeycomb composite sandwich structures
    • DOI 10.1361/105994999770346422
    • Shafizadeh, J.E., Seferis, J.C., Chesmar, E.F. and Geyer, R. 1999. "Evaluation of the In-Service Performance Behavior of Honeycomb Composite Sandwich Structures," Journal of materials engineering and performance, 8(6):661-668. (Pubitemid 32083336)
    • (1999) Journal of Materials Engineering and Performance , vol.8 , Issue.6 , pp. 661-668
    • Shafizadeh, J.E.1    Seferis, J.C.2    Chesmar, E.F.3    Geyer, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.