메뉴 건너뛰기




Volumn 16, Issue 2, 2011, Pages

Calculation of bone graft volume using 3D reconstruction system

Author keywords

Biological models; Stereolithography; Xenograft

Indexed keywords

BIOMATERIAL; TITANIUM;

EID: 79953659945     PISSN: 16984447     EISSN: 16986946     Source Type: Journal    
DOI: 10.4317/medoral.16.e260     Document Type: Article
Times cited : (5)

References (17)
  • 1
    • 33645164549 scopus 로고    scopus 로고
    • Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part I. The Concept
    • Lal K, White GS, Morea DN, Wright RF. Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part I. The concept. J Prosthodont. 2006;15:51-58.
    • (2006) J Prosthodont , vol.15 , pp. 51-58
    • Lal, K.1    White, G.S.2    Morea, D.N.3    Wright, R.F.4
  • 3
    • 0030756975 scopus 로고    scopus 로고
    • Stereolithographic models derived from x-ray computed tomography. Reproduction accuracy
    • Bouyssié JF, Bouyssié S, Sharrock P, Duran D. Stereolithographic models derived from x-ray computed tomography. Reproduction accuracy. Surg Radiol Anat. 1997;19:193-199.
    • (1997) Surg Radiol Anat , vol.19 , pp. 193-199
    • Bouyssié, J.F.1    Bouyssié, S.2    Sharrock, P.3    Duran, D.4
  • 4
    • 0027611512 scopus 로고
    • Integration of 3-D medical imaging and rapid prototyping to create stereolithographic models
    • Barker TM, Earwaker WJ, Frost N, Wakeley G. Integration of 3-D medical imaging and rapid prototyping to create stereolithographic models. Australas Phys Eng Sci Med. 1993;16:79-85.
    • (1993) Australas Phys Eng Sci Med , vol.16 , pp. 79-85
    • Barker, T.M.1    Earwaker, W.J.2    Frost, N.3    Wakeley, G.4
  • 12
    • 0034105638 scopus 로고    scopus 로고
    • Use of a stereolithography model for accurate, preoperative adaptation of a reconstruction plate
    • Kernan BT, Wimsatt JA 3rd. Use of a stereolithography model for accurate, preoperative adaptation of a reconstruction plate. J Oral Maxillofac Surg. 2000;58:349-351.
    • (2000) J Oral Maxillofac Surg , vol.58 , pp. 349-351
    • Kernan, B.T.1    Wimsatt, J.A.2
  • 13
    • 0032883597 scopus 로고    scopus 로고
    • An opinion survey of reported benefits from the use of stereolithographic models
    • Erickson DM, Chance D, Schmitt S, Mathis J. An opinion survey of reported benefits from the use of stereolithographic models. J Oral Maxillofac Surg. 1999;57:1040-1043.
    • (1999) J Oral Maxillofac Surg , vol.57 , pp. 1040-1043
    • Erickson, D.M.1    Chance, D.2    Schmitt, S.3    Mathis, J.4
  • 15
    • 4744366984 scopus 로고    scopus 로고
    • Design and fabrication of custom mandible titanium tray based on rapid prototyping
    • Singare S, Dichen L, Bingheng L, Yanpu L, Zhenyu G, Yaxiong L. Design and fabrication of custom mandible titanium tray based on rapid prototyping. Med Eng Phys. 2004;26:671-676.
    • (2004) Med Eng Phys , vol.26 , pp. 671-676
    • Singare, S.1    Dichen, L.2    Bingheng, L.3    Yanpu, L.4    Zhenyu, G.5    Yaxiong, L.6
  • 16
    • 0033250012 scopus 로고    scopus 로고
    • Reconstruction plates to bridge mandibular defects: A clinical and experimental investigation in biomechanical aspects
    • Yi Z, Jian-Guo Z, Guang-Yan Y, Ling L, Fu-Yun Z, Guo-Cheng Z. Reconstruction plates to bridge mandibular defects: a clinical and experimental investigation in biomechanical aspects. Int J Oral Maxillofac Surg. 1999;28:445-450.
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 445-450
    • Yi, Z.1    Jian-Guo, Z.2    Guang-Yan, Y.3    Ling, L.4    Fu-Yun, Z.5    Guo-Cheng, Z.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.