메뉴 건너뛰기




Volumn 12, Issue 3, 2011, Pages 162-166

Anatomical extent of pulmonary vein isolation after cryoballoon ablation for atrial fibrillation: Comparison between the 23 and 28 mm balloons

Author keywords

ablation; atrial fibrillation; cryoballoon

Indexed keywords

ADULT; ARTICLE; BALLOON EMBOLIZATION; CLINICAL ARTICLE; CONTROLLED STUDY; CORONARY SINUS; CRYOABLATION; FEMALE; HEART ATRIUM FIBRILLATION; HEART LEFT ATRIUM; HUMAN; MALE; PULMONARY VEIN ISOLATION;

EID: 79953653668     PISSN: 15582027     EISSN: None     Source Type: Journal    
DOI: 10.2459/JCM.0b013e328341d023     Document Type: Article
Times cited : (28)

References (11)
  • 1
  • 5
    • 10044263163 scopus 로고    scopus 로고
    • Pulmonary vein antrum isolation: Intracardiac echocardiography-guided technique
    • DOI 10.1046/j.1540-8167.2004.04428.x
    • Verma A, Marrouche NF, Natale A. Pulmonary vein antrum isolation: intracardiac echocardiography-guided technique. J Cardiovasc Electrophysiol 2004; 15:1335-1340. (Pubitemid 39612646)
    • (2004) Journal of Cardiovascular Electrophysiology , vol.15 , Issue.11 , pp. 1335-1340
    • Verma, A.1    Marrouche, N.F.2    Natale, A.3
  • 7
    • 34548803112 scopus 로고    scopus 로고
    • Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: Feasibility, complications, and short-term outcome
    • DOI 10.1093/eurheartj/ehm227
    • Van Belle Y, Janse P, Rivero-Ayerza M, Thornton A, Jessurun E, Theuns D, et al. Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome. Eur Heart J 2007; 28:2231-2237. (Pubitemid 47428935)
    • (2007) European Heart Journal , vol.28 , Issue.18 , pp. 2231-2237
    • Van Belle, Y.1    Janse, P.2    Rivero-Ayerza, M.J.3    Thornton, A.S.4    Jessurun, E.R.5    Theuns, D.6    Jordaens, L.7
  • 8
    • 39649105652 scopus 로고    scopus 로고
    • Balloon catheter ablation to treat paroxysmal atrial fibrillation: What is the level of pulmonary venous isolation?
    • Reddy V, Neuzil P, D'Avila A, Laragy M, Malchiano Z, Kralovech S, et al. Balloon catheter ablation to treat paroxysmal atrial fibrillation: what is the level of pulmonary venous isolation? Heart Rhythm 2008; 5:353-360.
    • (2008) Heart Rhythm , vol.5 , pp. 353-360
    • Reddy, V.1    Neuzil, P.2    D'Avila, A.3    Laragy, M.4    Malchiano, Z.5    Kralovech, S.6
  • 10
    • 33847250493 scopus 로고    scopus 로고
    • Pulmonary vein antrum isolation
    • Kanj M, Wazni O, Natale A. Pulmonary vein antrum isolation. Heart Rhythm 2007; 4 (3 Suppl):S73-S79.
    • (2007) Heart Rhythm , vol.4 , Issue.3 SUPPL.
    • Kanj, M.1    Wazni, O.2    Natale, A.3
  • 11
    • 44649124294 scopus 로고    scopus 로고
    • Efficacy of pulmonary vein isolation by cryoballoon ablation in patients with paroxysmal atrial fibrillation
    • Klein G, Oswald H, Gardiwal A, Lüsebrink U, Lissel C, Yu H, Drexler H. Efficacy of pulmonary vein isolation by cryoballoon ablation in patients with paroxysmal atrial fibrillation. Heart Rhythm 2008; 5:802-806.
    • (2008) Heart Rhythm , vol.5 , pp. 802-806
    • Klein, G.1    Oswald, H.2    Gardiwal, A.3    Lüsebrink, U.4    Lissel, C.5    Yu, H.6    Drexler, H.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.